In Situ FTIR-spektroskopi
FTIR-spektroskopi

In Situ FTIR-spektroskopi, reaksjonsovervåking i sanntid

Forstå reaksjonskinetikk, vei og mekanisme med ReactIR

Fourier Transform Infrared (FTIR) spektroksopi
Reaksjonsanalyse for laboratorie og produskjon
Reaksjonsovervåkning
Forstå trykkreaksjoner
In situ overvåkning av kjemiske reaksjoner

Produkter og detaljer

Overvåking av kjemiske reaksjoner i sanntid

 
Produkter og detaljer
Filter:
Sett filter
Clear All
 
For Use In
Software
Detector
Optical Range (Base Unit)
Purge Requirement
Material No.: 30456495
Se detaljer
For Use InLaboratory
SoftwareiC IR
DetectorTE MCT
Optical Range (Base Unit)4000 - 800 cm-1
Purge RequirementNo
Weight9.2 lb (4.2 kg)
CommunicationUSB
Resolution4 cm-1 maximum
Probe Optical Window2500 – 650 cm-1 maximum (Fiber Probe); 2500 - 650 cm-1 maximum (Micro Flow Cell); 4000 – 650 cm-1 (Sentinel)
Wetted MaterialsAlloy C22; Diamond or Silicon; Gold or PTFE
Probe Pressure (Maximum)69bar (6.3 & 9.5mm Fiber Probe); 35bar (Micro Flow Cell); 206bar (Sentinel)
Probe Temperature (Maximum)180°C (Fiber Probe); 60°C (Micro Flow Cell); 300°C (Sentinel)
Safety CertificationNRTL/C: UL 61010-1, CSA 22.2 No. 61010-1, EN 61326; CE: EN/IEC 61010-1:2012, IEC 61326
Probe pH Range1 – 14 (Diamond); 1 – 9 (Silicon)
Material No.: 14000003
Se detaljer
For Use InLaboratory
SoftwareiC IR
DetectorLN2 MCT; SE MCT
Optical Range (Base Unit)4000 – 650 cm-1
Purge RequirementNo
Dimensions (WxHxD)180 mm x 274 mm x 249 mm
Weight9 kg
CommunicationUSB 2.0
Resolution4 cm -1 maximum
Probe Optical Window2500 – 650 cm-1 maximum (Fiber Probe)
Wetted MaterialsAlloy C-22; Diamond or Silicon; Gold
Probe Pressure (Maximum)69bar (6.3 & 9.5mm Fiber Probe); 107bar (Sentinel)
Probe Temperature (Maximum)180°C (Fiber Probe); 200°C (Sentinel)
Safety CertificationEMC Directive 2004/109/EC, Low Voltage Directive 2006/95/IEC
Probe pH Range1 – 14 (Diamond); 1 – 9 (Silicon)
Material No.: 14000003
Se detaljer
For Use InLaboratory
SoftwareiC IR
DetectorLN2 MCT; SE MCT
Optical Range (Base Unit)4000 – 650 cm-1
Purge RequirementNo
Dimensions (WxHxD)180 mm x 274 mm x 249 mm
Weight9 kg
CommunicationUSB 2.0
Resolution4 cm -1 maximum
Probe Optical Window2500 – 650 cm-1 maximum (Fiber Probe)
Wetted MaterialsAlloy C-22; Diamond or Silicon; Gold
Probe Pressure (Maximum)69bar (6.3 & 9.5mm Fiber Probe); 107bar (Sentinel)
Probe Temperature (Maximum)180°C (Fiber Probe); 200°C (Sentinel)
Safety CertificationEMC Directive 2004/109/EC, Low Voltage Directive 2006/95/IEC
Probe pH Range1 – 14 (Diamond); 1 – 9 (Silicon)
Material No.: 14170003
Se detaljer
For Use InLaboratory
ProgramvareConcIRT Pro; iC IR; iC Kinetics; iC Quant
DetectorLN2 MCT
Optical Range (Base Unit)4000-650 cm-1
Purge RequirementYes
Mål Dybde279.0 mm
Vekt16.0 kg
KommunikasjonUSB cable
Resolution4 cm -1 maximum
Probe Optical Window2500-650 cm-1 maximum (Fiber Probe); 4000-650cm-1 (Sentinel)
Wetted MaterialsAlloy C-22; Diamond or Silicon; Gold
Probe Pressure (Maximum)107bar (Sentinel); 69bar (6.35mm Fiber Probe)
Probe Temperature (Maximum)180°C (Fiber Probe); 200°C (Sentinel)
Safety CertificationEMC Directive 2004/109/EC, Low Voltage Directive 2006/95/IEC
Probe pH Range1-10 (Silicon); 1-14 (Diamond)
Material No.: 14474487
Se detaljer
For Use InLab, Pilot Plant or Production
ProgramvareConcIRT Pro; iC IR; iC Process; iC Quant
DetectorDTGS; SE MCT
Optical Range (Base Unit)4000-650 cm-1
Purge RequirementYes
Mål Dybde305.0 mm
Vekt37.0 kg
KommunikasjonEthernet TCP/IP
Resolution4 cm -1 maximum
Probe Optical Window2500-650 cm-1 maximum (Fiber Probe); 4000-650cm-1 (Sentinel)
Wetted MaterialsAlloy C-22; Diamond or Silicon; Gold
Probe Pressure (Maximum)107bar (Sentinel); 69bar (6.35mm Fiber Probe)
Probe Temperature (Maximum)180°C (Fiber Probe); 200°C (Sentinel)
Safety CertificationArea Classification – NON-HAZARDOUS, MET Mark E112462, UL61010-1 & CSA C22.2 No. 61010-1; CSA C22.2 No. 61010-1; Area Classification – NON-HAZARDOUS, MET Mark E112462, UL61010-1
Probe pH Range1-10 (Silicon); 1-14 (Diamond)
Material No.: 14474485
Se detaljer
For Use InLab, Pilot Plant or Production
SoftwareiC IR; iC Process
DetectorDTGS; SE MCT
Optical Range (Base Unit)4000 – 650 cm-1
Purge RequirementYes
Dimensions (WxHxD)457 mm x 774 mm x 310 mm
Weight45 kg
CommunicationLC terminated Ethernet TCP/IP, duplex fiber optic
Resolution4 cm -1 maximum
Probe Optical Window2500 – 650 cm-1 maximum (Fiber Probe); 4000 – 650 cm-1 (Sentinel)
Wetted MaterialsAlloy C-22; Diamond or Silicon; Gold
Probe Pressure (Maximum)107bar (Sentinel); 69bar (6.3 & 9.5mm Fiber Probe)
Probe Temperature (Maximum)180°C (Fiber Probe); 200°C (Sentinel)
Safety CertificationArea Classification – HAZARDOUS, MET Mark E112462, UL61010-1 & CSA C22.2 No. 61010-1; ATEX listing - TRAC12ATEX0001X, Equipment marking - Ex d op pr px [ia IIC] IIB+H2 T4 Gb; NFPA 496, Class I, Division 1, Groups B, T4
Probe pH Range1 – 14 (Diamond); 1 – 9 (Silicon)
Material No.: 304725451
Se detaljer
For Use InLaboratory: EasyMax/OptiMax
SoftwareiC Raman 7
Detector2-stage TE Cooled CCD
Optical Range (Base Unit)100cm-1 to 3200cm-1
Comparison

Dokumentasjon

Datablad

ReactIR 15
Study reaction progression and gain specific information about reaction initiation, conversion, intermediates and endpoint.
ReactIR 45P In Situ Process FTIR
Successfully move processes from lab to pilot plant and production with in situ process FTIR spectroscopy. Gain in-depth reaction understanding, ident...
ReactIR Sampling Technology
ReactIR in situ sampling technology assures usability in a wide range of batch and continuous reaction conditions.
ReactIR Instrument Performance Assurance (IPA) Module
Validate ReactIR wavenumber accuracy and calibrate to a Polystyrene standard certified by the National Institute of Standards and Technology (NIST) fo...

Relaterte produkter og løsninger

Syntesearbeidsstasjoner for kjemikalie- og prosessutvikling
Reduser tidsbruk for kjemisk utvikling og prosessutvikling ved å skifte ut tradisjonelle rundbunnede kolber og mantlede laboratoriereaktorer
EasySampler
EasySampler er utviklet for å fjerne disse utfordringene, ved å utføre en automatisert og solid inline-metode for å ta representative prøver av reaksj...
partikkelmåling
Partikkelmåling - optimerer og kontroller partikler og dråper med in situ partikkelsysstemkarakterisering i sanntid
Reaksjonskalorimetre for prosessutvikling, sikkerhet og oppskalering
Reaksjonskalorimetri fra screening til produksjon

Programvare

iC IR Software
Spectroscopic data increases chemical understanding and knowledge of the chemical process, including reaction initiation, endpoint, mechanism, pathway...
iC Kinetics Software
Optimize chemical reactions with a fast graphical way to describe the characteristics of a chemical reaction and create a kinetic model. This model c...
iC Process Software
Monitor critical control parameters determined in the laboratory to production environment. Supports industry standard communication protocols for in...
iC Data Center
Capture, Prepare, Share Experimental Data

Programmer

Organisk syntese
Kjemikere som jobber med syntetisk organisk kjemi oppdager og utvikler innovative kjemiske reaksjoner og prosesser.
Chemical Process Development & Scale-Up
Design Robust and Sustainable Chemical Processes For Faster Transfer To Pilot Plant and Production
Process Analytical Technology (PAT)
Process Analytical Technology (PAT) is changing the way R&D, scale-up, and manufacturing are performed. PAT transforms productivity, improves safety,...
Measuring Polymerization Reactions
Measuring and understanding polymerization reactions, mechanisms, kinetics, reactivity ratios, and activation energies lead researchers to employ in s...
Fermentation and BioProcessing
Characterize & Optimize Fermentation & Bioprocesses in Real Time to Maximize Production
Continuous Flow Chemistry
Continuous flow chemistry opens options with exothermic synthetic steps that are not possible in batch reactors, and new developments in flow reactor...

Service

22 30 44 90
Kontakt service

Utforsk våre tjenester – Skreddersydd for å passe ditt utstyr

Vi tilbyr støtte og service for måleutstyr gjennom hele livssyklusen, fra installasjon til forebyggende vedlikehold og kalibrering, til reparasjon av utstyr.

Driftstid
Support & Reperasjon
Ekpertise
Trening & Rådgivning
 
 
 
 
 
 
 
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.