    Material No.: 14000003
    For Use InLaboratory
    ProgramvaraConcIRT Pro; iC IR; iC Kinetics; iC Quant
    DetectorLN2 MCT; SE MCT
    Optical Range (Base Unit)4000-650 cm-1
    Purge RequirementNo
    Dimensioner Djup249.0 mm
    Vikt9.0 kg
    KommunikationUSB 2.0
    Resolution4 cm -1 maximum
    Probe Optical Window2500-650 cm-1 maximum (Fiber Probe)
    Material i kontakt med vätaAlloy C-22; Diamond or Silicon; Gold
    Probe Pressure (Maximum)69bar (6.3 & 9.5mm Fiber Probe); 107bar (Sentinel)
    Probe Temperature (Maximum)180°C (Fiber Probe); 200°C (Sentinel)
    Safety CertificationEMC Directive 2004/109/EC, Low Voltage Directive 2006/95/IEC
    Probe pH Range1-10 (Silicon); 1-14 (Diamond)
    Material No.: 14000003
    For Use InLaboratory
    ProgramvaraConcIRT Pro; iC IR; iC Kinetics; iC Quant
    DetectorLN2 MCT; SE MCT
    Optical Range (Base Unit)4000-650 cm-1
    Purge RequirementNo
    Dimensioner Djup249.0 mm
    Vikt9.0 kg
    KommunikationUSB 2.0
    Resolution4 cm -1 maximum
    Probe Optical Window2500-650 cm-1 maximum (Fiber Probe)
    Material i kontakt med vätaAlloy C-22; Diamond or Silicon; Gold
    Probe Pressure (Maximum)69bar (6.3 & 9.5mm Fiber Probe); 107bar (Sentinel)
    Probe Temperature (Maximum)180°C (Fiber Probe); 200°C (Sentinel)
    Safety CertificationEMC Directive 2004/109/EC, Low Voltage Directive 2006/95/IEC
    Probe pH Range1-10 (Silicon); 1-14 (Diamond)
    Material No.: 14170003
    For Use InLaboratory
    ProgramvaraConcIRT Pro; iC IR; iC Kinetics; iC Quant
    DetectorLN2 MCT
    Optical Range (Base Unit)4000-650 cm-1
    Purge RequirementYes
    Dimensioner Djup279.0 mm
    Vikt16.0 kg
    KommunikationUSB cable
    Resolution4 cm -1 maximum
    Probe Optical Window2500-650 cm-1 maximum (Fiber Probe); 4000-650cm-1 (Sentinel)
    Material i kontakt med vätaAlloy C-22; Diamond or Silicon; Gold
    Probe Pressure (Maximum)107bar (Sentinel); 69bar (6.35mm Fiber Probe)
    Probe Temperature (Maximum)180°C (Fiber Probe); 200°C (Sentinel)
    Safety CertificationEMC Directive 2004/109/EC, Low Voltage Directive 2006/95/IEC
    Probe pH Range1-10 (Silicon); 1-14 (Diamond)
    Material No.: 14474487
    For Use InLab, Pilot Plant or Production
    ProgramvaraConcIRT Pro; iC IR; iC Process; iC Quant
    DetectorDTGS; SE MCT
    Optical Range (Base Unit)4000-650 cm-1
    Purge RequirementYes
    Dimensioner Djup305.0 mm
    Vikt37.0 kg
    KommunikationEthernet TCP/IP
    Resolution4 cm -1 maximum
    Probe Optical Window2500-650 cm-1 maximum (Fiber Probe); 4000-650cm-1 (Sentinel)
    Material i kontakt med vätaAlloy C-22; Diamond or Silicon; Gold
    Probe Pressure (Maximum)107bar (Sentinel); 69bar (6.35mm Fiber Probe)
    Probe Temperature (Maximum)180°C (Fiber Probe); 200°C (Sentinel)
    Safety CertificationArea Classification – NON-HAZARDOUS, MET Mark E112462, UL61010-1 & CSA C22.2 No. 61010-1; CSA C22.2 No. 61010-1; Area Classification – NON-HAZARDOUS, MET Mark E112462, UL61010-1
    Probe pH Range1-10 (Silicon); 1-14 (Diamond)
    Material No.: 14474485
    For Use InLab, Pilot Plant, or Production
    SoftwareiC IR;iC Process
    DetectorDTGS;SE MCT
    Optical Range (Base Unit)4000 – 650 cm-1
    Purge RequirementYes
    Dimensions (WxHxD)457 mm x 774 mm x 310 mm
    Weight100 lb (45 kg)
    CommunicationLC terminated Ethernet TCP/IP, duplex fiber optic
    Resolution4 cm-1 maximum
    Probe Optical Window2500 – 650 cm-1 maximum (Fiber Probe);4000 – 650 cm-1 (Sentinel)
    Wetted MaterialsAlloy C22;Diamond or Silicon;Gold
    Probe Pressure (Maximum)107bar (Sentinel);69bar (6.3 & 9.5mm Fiber Probe)
    Probe Temperature (Maximum)180°C (Fiber Probe);200°C (Sentinel)
    Safety CertificationArea Classification - HAZARDOUS, MET Mark E112462, UL61010-1 & CSA C22.2 No 61010-1 & NFPA 496, Class I, Division 1, Groups B;ATEX listing - TRAC12ATEX0001X, Equipment marking - Ex d op pr px [ia IIC] IIB+H2 T4 Gb;NFPA 496, Class I, Division 1, Groups B, T4
    Probe pH Range1 – 14 (Diamond);1 – 9 (Silicon)
    Comparison
     
     
     
     
     
     
     
    Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.