Outstanding Performance at Low ppb-Level
The Pure Water Optical DO sensor delivers outstanding measurement performance with a low detection limit for low ppb-level ultra-pure water applications.
Easy and Fast Maintenance
The OptoCap™ oxygen-sensing element delivers convenience with easy maintenance, eliminating liquid handling and time-consuming sensor polarisation.
Minimum Drift and Short Response Time
The minimum drift and short response time of the Pure Water Optical DO probe provides for improved oxygen monitoring.
หมายเลขกำกับผลิตภัณฑ์: 30041040
พารามิเตอร์การวัดค่า | ออกซิเจน |
ความแม่นยำ | ± 2% of reading or 2ppb, whichever is greate |
เวลาตอบสนอง | 98% of final value in <20s |
Sample Rate | Adjustable between 1 and 60 seconds |
ISM (ดิจิตอล) หรืออะนาล็อก | ISM (ดิจิตอล) |
อุณหภูมิการทำงาน (เซสเซียส) | 0 to 121°C |
อุณหภูมิการทำงาน (ฟาเรนไฮต์) | 32 to 250°F |
แรงดันการใช้งาน (Bar) | 0.2 - 12 bar |
แรงดันการใช้งาน (PSI) | 2.9 - 174 psi absolute |
ช่วงอุณหภูมิการวัด (เซสเซียส) | 0 - 50 °C |
ช่วงอุณหภูมิการวัด (ฟาเรนไฮต์) | 32 - 122 °F |
ส่วนเชื่อมต่อระบบ | ¼" NPT(F) |
ความยาวเซ็นเซอร์ | 120 mm |
วัสดุโอริง | EPDM (FDA-positive listed) |
วัสดุเมมเบรน | Silicone |
ขั้วต่อสายเคเบิล | 5-pin |
ใบรับรองอื่น | CE |
ผ่านใบรับรองสำหรับการใช้งานในพื้นที่อันตราย | ไม่ |
สื่อ/การใช้งานหลัก | น้ำในเซมิคอนดักเตอร์ น้ำ/ไอน้ำในโรงไฟฟ้า |
ผ่านใบรับรองด้านสุขลักษณะ/ความเข้ากันได้กับเนื้อเยื่อในร่างกาย | ไม่ |
นึ่งฆ่าเชื้อได้/ฆ่าเชื้อได้ | No |
วัสดุส่วนเปียก | Stainless steel, silicone, EPDM O-ring |
ช่วงการวัดค่า | 0-5000 ppb |
เทคโนโลยีการวัดค่า | การชุบสารเรืองแสงออพติคัล |
การชดเชยอุณหภูมิ | อัตโนมัติ |
เส้นผ่านศูนย์กลางเซ็นเซอร์ | 12 มม. |
ความต้านทานแรงดันเชิงกล (PSI) | 2.9 - 174 psi absolute |
รุ่น | UPW DO sensors |
ดีไซน์ขั้วต่อ | ตรง |
ความต้านทานแรงดันเชิงกล (Bar) | สูงสุด 12 Bar |
Instant Availability, Accurate Results
Through innovative fluorescence-quenching technology, the Pure Water Optical DO sensor delivers highly accurate O2 measurements with enhanced signal stability and a fast response time. Increase productivity by eliminating delays in measuring.
Higher Performance, Faster Response
The probe’s OptoCap™ sensing element supports accurate oxygen determination without time-consuming electrolyte handling. Response time is in the order of four to five times faster than that of polarographic sensors.
Easy, Infrequent Maintenance
With no more than the annual replacement of the OptoCap™, the Pure Water Optical DO Sensor eliminates the need for polarisation, dramatically reducing downtime. In addition, the single-piece replacement design provides easy maintenance without electrolyte handling.
Advanced Predictive Insights
Embedded ISM technology allows Plug and Measure capabilities and simplifies maintenance and calibration. Using advanced sensor diagnostics, maximise your uptime by predicting their maintenance needs so that action can be taken before measurements are affected.
The DS AK9-RJ12 is a USB cable adaptor for connecting ISM 1-wire sensors to iSense software. This allows pH, DO and CO2 sensors to be evaluated, maintained and calibrated in the workshop or laboratory.
Diagnostics Away From the Transmitter
The iLink module allows you to access all of the diagnostics of your ISM sensors away from the process with iSense desktop software.
Application Profiling Drives Performance
Store application data on iSense and load directly into an ISM sensor. This allows sensors to learn from preceding sensors in the same process.
Easy Access to Paper Free Documentation
The iLink cable allows sensor calibration and adjustment protocols to be generated automatically in iSense and stored in a fully digital database.
หมายเลขกำกับผลิตภัณฑ์: 52300383