Stručný popisConventional pH sensor with pH sensitive membrane glass
Rozsah měřenípH 3-10
Snímací prvkyGlass pH and Reference Electrodes, Lead-Free
Vestavěná teplotní sondaPt1000
Nulový bod7.20 ±0.25 pH
Kalibrace1-point process
Materiál dříkuHigh density polyethylene, USP 88 class VI
Materiál O-kroužkuEPDM, USP 88 class VI
Procesní přípojkyEldon James 1' port disc, with retainer
Sterilizace zářením gama25…45 kGy
Operating Temperature5…60°C (41…140°F)
Storage temperature5…25°C (41…77°F)
Odolnost vůči mechanickému tlaku "2 barg / 40 °C (29 psig / 104 °F), 1 barg / 60 °C (15 psig / 140 °F)"
CertifikaceUSP 88 class VI for all wetted polymer parts, factory calibration
Více detailů
Stručný popisOptical dissolved oxygen sensor
Rozsah měření0…250% air
Snímací prvkyOptical spot (Fluorescensce quenching)
Vestavěná teplotní sondaPt1000
Kalibrace1-point air
Materiál dříkuHigh density polyethylene, USP 88 class VI
Materiál O-kroužkuEPDM, USP 88 class VI
Procesní přípojkyEldon James 1' port disc
Sterilizace zářením gama25…45 kGy
Operating Temperature5…60°C (41…140°F)
Storage temperature5…25°C (41…77°F)
Odolnost vůči mechanickému tlaku "2 barg / 40 °C (29 psig / 104 °F), 1 barg / 60 °C (15 psig / 140 °F)"
CertifikaceUSP 88 class VI for all wetted polymer parts
Porovnání

Dokumenty

Application Note

Application Note: Differences in Operation Between Analytical Multi-Use and Single-Use Sensors in Bioreactors
This application note provides information on the important trend towards the deployment of single-use bioreactors (SUBs) in the bioprocess industry....

Technická specifikace

Technical Data: InSUS x07 Sensor Series
The InSUS™ x07 sensor series for single-use technology bioprocesses cover the measurement parameters pH and dissolved oxygen (DO).

Instruction Manuals

Instruction Manual: InSUS Head for Optical Single-Use O₂ Sensors
These operating instructions contain all the information needed for safe and proper use of the optical sensor head.
Instruction Manual: Information for InSUS fiber optic cable
The enclosed adapter must be used, if the fiber optic cable is connected to sensors of the type InSUS 607. Mount the adapter – as shown in the photos...
M300 / M400 2G Quick Calibration Guide For pH Single-Use Sensors Type InSUS 307
METTLER TOLEDO InSUS™ pH sensors are analog, gamma irradiation-sterilizable single-use pH sensors with an integrated Pt 1000 temperature probe.

Nabídka servisních služeb

+420 226 808 163
Kontaktovat servis
Provoz
Podpora a opravy
Shoda
Kalibrace a zajišťování jakosti
Odbornost
Školení a konzultace
 
 
 
 
 
 
 
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.