Compact Transmitter M100 - Overview - METTLER TOLEDO

    Compact Transmitter M100

    Simple Installation

    Products and Specs

     
    Products and Specs
    Filter:
    Set filter
    Clear All
     
    Parameters
    Hazardous Area Classification
    Sensor Type
    Communication
    See details
    ParametersISM 1-wire pH, amperometric oxygen and conductivity sensors
    Hazardous Area ClassificationATEX / IECEx Zone 1,
    CSA Class I; II, III Div 1, Class 1, Zone 0,
    NEPSI Ex Zone 1
    Sensor TypeISM
    CommunicationHART®
    ISM featuresPlug and Measure, DLI, ACT, TTM
    EnclosureIP 66, NEMA 4X
    Supply voltage14 – 30 VDC
    Analog output1 × 4 to 20 mA (loop powered), galvanically isolated
    See details
    ParametersISM 1-wire pH, amperometric oxygen and conductivity sensors
    Hazardous Area ClassificationNot available
    Sensor TypeISM
    CommunicationHART®
    ISM featuresPlug and Measure, DLI, ACT, TTM
    EnclosureIP 20
    Supply voltage14 – 30 VDC
    Analog output1 × 4 to 20 mA (loop powered), galvanically isolated
    See details
    ParametersISM pH, amperometric oxygen, and carbon dioxide sensors
    Hazardous Area ClassificationNot available
    Sensor TypeISM
    CommunicationMODBUS RTU
    ISM featuresPlug and Measure, DLI, ACT, TTM
    EnclosureIP 67
    MountingOn head of 1-wire sensor: AK9
    Supply voltage24 VDC
    Analog outputActive 2 × 4 to 20 mA, galvanically isolated to passive DCS card
    Sensor compatibilityISM 1-wire pH, DO (amperometric) and carbon dioxide sensors
    M100 SM 1-wire30 365 366
    See details
    ParametersOptical oxygen sensors
    Hazardous Area ClassificationNot available
    Sensor TypeISM
    CommunicationMODBUS RTU
    ISM featuresPlug and Measure, DLI, ACT, TTM
    EnclosureIP 67
    MountingOn head of RS 485 sensor: VP8
    Supply voltage24 VDC
    Analog outputActive 2 × 4 to 20 mA, galvanically isolated to passive DCS card
    Sensor compatibilityISM RS485 optical DO sensors
    M100 SM 1-wire30 365 367
    Comparison

    Documentation

    Device Drivers

    M100 2XH DTM Setup V1.00.0003
    HART, DTM for PACTware ™: Version 4.x

    Application Solutions

    Application Solutions for M100 Modbus Programmers Guide
    This programmers guides explains general modbus informations, implemented modbus registers in M100, detailed description of the implemented Modbus re...

    Technical Specifications

    Technical Data: M100 DR DIN Rail Transmitter for pH/ORP, pH/pNa, Oxygen and Conductivity
    The M100 DR DIN rail transmitter is a 2-wire transmitter with HART® communication capability for analytical measurements. The M100 DR is a single-chan...

    Datasheets

    Datasheets for Sensor Mount Transmitter M100 SM
    The M100 Sensor Mount (SM) is a single-channel transmitter. It allows the connection on biocontrollers of 1-wire ISM sensors for measuring pH, ampDO a...

    Users’ Information

    Operating Instructions for Head Mount Transmitter M100
    These operating instructions offer important notes on handling of the M100 transmitter of METTLER TOLEDO. A prerequisite for safe work is compliance w...
    Operating Instructions: DIN Rail Transmitter M100 DR
    These operating instructions offer important notes on handling of the M100 DR transmitter of METTLER TOLEDO. A prerequisite for safe work is complianc...
    Instruction Manuals for Sensor Mount Transmitter M100 SM
    This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits ar...
    Quick Setup Guide Transmitter M100
    The M100 is a 2-wire head mount transmitter for analytical measurements with HART communication capabilities. The M100 is a single-channel, multi-para...
    Quick Setup Guide: Transmitter M100/2H DR
    The M100 DIN rail transmitter is a 2-wire transmitter for analytical measurements with HART communication capabilities. The M100 is a single-channel,...

    Webinars

    Webinar: Small Footprint Installation for Hazardous Areas
    The continuous, real-time information that in situ analyzers provide has huge advantages over lab analyses of grab samples, and in the end leads to mu...

    Videos

    The world's first head mount analyzer transmitter
    Watch the video to see how easy in-situ analysis becomes with the M100 head mount transmitter.

    Services

    888 687 7687
    Call Service
     
     
     
     
     
     
     
    Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.