Compact Transmitter M100 - Overview - METTLER TOLEDO
M100 Compact Transmitter

Compact Transmitter M100

Simple Installation

M100 head mount transmitter for analytical measurements
Control room, and chemical plant
Intelligent Sensor Management
Versatile

M100 DinRail on Rail

Products and Specs

 
Products and Specs
Filter:
Set filter
Clear All
 
Parameters
Hazardous Area Classification
Sensor Type
Communication
See details
ParametersISM 1-wire pH, amperometric oxygen and conductivity sensors
Hazardous Area ClassificationATEX / IECEx Zone 1,
CSA Class I; II, III Div 1, Class 1, Zone 0,
NEPSI Ex Zone 1
Sensor TypeISM
CommunicationHART®
ISM featuresPlug and Measure, DLI, ACT, TTM
EnclosureIP 66, NEMA 4X
Supply voltage14 – 30 VDC
Analog output1 × 4 to 20 mA (loop powered), galvanically isolated
See details
ParametersISM 1-wire pH, amperometric oxygen and conductivity sensors
Hazardous Area ClassificationNot available
Sensor TypeISM
CommunicationHART®
ISM featuresPlug and Measure, DLI, ACT, TTM
EnclosureIP 20
Supply voltage14 – 30 VDC
Analog output1 × 4 to 20 mA (loop powered), galvanically isolated
See details
ParametersISM pH, amperometric oxygen, and carbon dioxide sensors
Hazardous Area ClassificationNot available
Sensor TypeISM
CommunicationMODBUS RTU
ISM featuresPlug and Measure, DLI, ACT, TTM
EnclosureIP 67
MountingOn head of 1-wire sensor: AK9
Supply voltage24 VDC
Analog outputActive 2 × 4 to 20 mA, galvanically isolated to passive DCS card
Sensor compatibilityISM 1-wire pH, DO (amperometric) and carbon dioxide sensors
M100 SM 1-wire30 365 366
See details
ParametersOptical oxygen sensors
Hazardous Area ClassificationNot available
Sensor TypeISM
CommunicationMODBUS RTU
ISM featuresPlug and Measure, DLI, ACT, TTM
EnclosureIP 67
MountingOn head of RS 485 sensor: VP8
Supply voltage24 VDC
Analog outputActive 2 × 4 to 20 mA, galvanically isolated to passive DCS card
Sensor compatibilityISM RS485 optical DO sensors
M100 SM 1-wire30 365 367
Comparison

Documentation

Device Drivers

M100 2XH DTM Setup V1.00.0003
HART, DTM for PACTware ™: Version 4.x

Application Solutions

Application Solutions for M100 Modbus Programmers Guide
This programmers guides explains general modbus informations, implemented modbus registers in M100, detailed description of the implemented Modbus re...

Technical Specifications

Technical Data: M100 DR DIN Rail Transmitter for pH/ORP, pH/pNa, Oxygen and Conductivity
The M100 DR DIN rail transmitter is a 2-wire transmitter with HART® communication capability for analytical measurements. The M100 DR is a single-chan...

Datasheets

Datasheets for Sensor Mount Transmitter M100 SM
The M100 Sensor Mount (SM) is a single-channel transmitter. It allows the connection on biocontrollers of 1-wire ISM sensors for measuring pH, ampDO a...

Users’ Information

Operating Instructions for Head Mount Transmitter M100
These operating instructions offer important notes on handling of the M100 transmitter of METTLER TOLEDO. A prerequisite for safe work is compliance w...
Operating Instructions: DIN Rail Transmitter M100 DR
These operating instructions offer important notes on handling of the M100 DR transmitter of METTLER TOLEDO. A prerequisite for safe work is complianc...
Instruction Manuals for Sensor Mount Transmitter M100 SM
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits ar...
Quick Setup Guide Transmitter M100
The M100 is a 2-wire head mount transmitter for analytical measurements with HART communication capabilities. The M100 is a single-channel, multi-para...
Quick Setup Guide: Transmitter M100/2H DR
The M100 DIN rail transmitter is a 2-wire transmitter for analytical measurements with HART communication capabilities. The M100 is a single-channel,...

Webinars

Webinar: Small Footprint Installation for Hazardous Areas
The continuous, real-time information that in situ analyzers provide has huge advantages over lab analyses of grab samples, and in the end leads to mu...

Videos

The world's first head mount analyzer transmitter
Watch the video to see how easy in-situ analysis becomes with the M100 head mount transmitter.

Services

888 687 7687
Call Service
 
 
 
 
 
 
 
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.