Need assistance?
Our team is here to achieve your goals. Speak with our experts.

DO Sensor InPro6950i/12/70

Trace Oxygen Probe for Food and Beverage.The InPro 6950i dissolved oxygen sensor with 12 mm diameter body offers excellent accuracy at the lowest oxygen levels due to the built-in 4-electrode measurement system. It also measures trace oxygen concentrations and features ISM diagnostics.

Sensor for Hygienic Applications

The sensor has been developed to comply fully with the EHEDG and FDA flat-surface recommendations for extremely high-level hygienic applications.

Durable and Hygienic Design

The 316L stainless steel construction allows for CIP, steam sterilization or autoclaving in place. The sensor finish eliminates process contamination.

Advanced Predictive Diagnostics

This DO sensor has Intelligent Sensor Management (ISM) technology, offering easier calibration and predictive diagnostics to reduce maintenance.

Material No.: 52206127

Ring for tilbud
Spesifikasjoner - DO Sensor InPro6950i/12/70
Måleparameter
Oksygen
Måleteknologi
Amperometrisk/Polarografisk
Responstid (Text)
Hovedmedium/bruksområde
Næringsmiddel
ISM (digital) eller analog
ISM (digital)


Sensordiameter
O-ringmateriale
Silikon
Prosesstilkobling
Pg 13,5

70 mm
Materiale, våt membran
PTFE
Koblingsdesign
Rett
Modellfamilie
Autoklaverbar/steriliserbar
Ja

Ja
Mekanisk temp. Område
23 °F
249,8 °F
Driftstrykk (PSI)
Kabelkontakt
Godkjenninger for hygiene-/biokompatibilitet
Godkjenninger for farlige områder
Sertifikater og godkjenninger
Sensorsignal i luft ved 25 °C (77 °F)
IP-klassifisering
Måleområde (2)
Operating Range
Målt trykkmotstand
0,2 bar
9 bar
Steriliserbar/autoklaverbar
Ja
Restsignal i oksygenfritt medium
Deteksjonsgrense
0,1 ppb

Easy to Integrate

The InPro 6950i DO sensor is easy to integrate into your process. Its watertight VP connector (IP68) helps ensure reliable measurements.

Long Membrane Life

Ingold's PTFE/silicone membranes have been designed with an internal steel mesh that makes the membrane more rugged and dramatically increases membrane life.

Modular Design Saves Time and Money

Replacement of the anode/cathode assembly has been made simple with state-of-the-art interior sensor design, thereby reducing maintenance costs. No complicated service procedures: the quick-disconnect interior body can be replaced in less than 5 minutes.

High Process Safety

The FDA-compliant materials of construction and the easy-to-clean hygienically polished N5 grade surface finish satisfy regulatory requirements.

Tilbehør

Forbruksvarer

Software

Få ditt tilbud
DO Sensor InPro6950i/12/70
FDA
USP Class VI