Single-use Sensors
Single-use Sensors

Single-use Sensors for Bag Manufacturers

pH and Dissolved Oxygen for stirred Single-use Reactors (> 20 L)

Làm cách nào để chúng tôi có thể hỗ trợ bạn?
Designed for Single-Use Bag Manufacturers
Easy and Safe Installation and Integration
Reliable, Straightforward Use in Biocontrollers

Sản phẩm & Cấu hình

 
Sản phẩm & Cấu hình
Lọc:
Bộ lọc
Clear All
 
Short description
Phạm vi đo
Xem chi tiết
Short descriptionConventional pH sensor with pH sensitive membrane glass
Phạm vi đo pH 3-10
Phần tử cảm biếnGlass pH and Reference Electrodes, Lead-Free
Đầu dò nhiệt độ tích hợpPt1000
Điểm không7.20 ±0.25 pH
Calibration1-point process
Vật liệu thân cảm biếnHigh density polyethylene, USP 88 class VI
Vật liệu vòng OEPDM, USP 88 class VI
Process connectionEldon James 1' port disc, with retainer
Có thể khử trùng bằng tia gamma25…45 kGy
Operating Temperature5…60°C (41…140°F)
Storage temperature5…25°C (41…77°F)
Mechanical pressure resistance"2 barg / 40 °C (29 psig / 104 °F), 1 barg / 60 °C (15 psig / 140 °F)"
Phê duyệtUSP 88 class VI for all wetted polymer parts, factory calibration
Xem chi tiết
Short descriptionOptical dissolved oxygen sensor
Phạm vi đo 0…250% air
Phần tử cảm biếnOptical spot (Fluorescensce quenching)
Đầu dò nhiệt độ tích hợpPt1000
Calibration1-point air
Vật liệu thân cảm biếnHigh density polyethylene, USP 88 class VI
Vật liệu vòng OEPDM, USP 88 class VI
Process connectionEldon James 1' port disc
Có thể khử trùng bằng tia gamma25…45 kGy
Operating Temperature5…60°C (41…140°F)
Storage temperature5…25°C (41…77°F)
Mechanical pressure resistance"2 barg / 40 °C (29 psig / 104 °F), 1 barg / 60 °C (15 psig / 140 °F)"
Phê duyệtUSP 88 class VI for all wetted polymer parts
Comparison

Tài liệu

Application Note

Application Note: Differences in Operation Between Analytical Multi-Use and Single-Use Sensors in Bioreactors
This application note provides information on the important trend towards the deployment of single-use bioreactors (SUBs) in the bioprocess industry....

Thông số kỹ thuật

Technical Data: InSUS x07 Sensor Series
The InSUS™ x07 sensor series for single-use technology bioprocesses cover the measurement parameters pH and dissolved oxygen (DO).

Instruction Manuals

Instruction Manual: InSUS Head for Optical Single-Use O₂ Sensors
These operating instructions contain all the information needed for safe and proper use of the optical sensor head.
Instruction Manual: Information for InSUS fiber optic cable
The enclosed adapter must be used, if the fiber optic cable is connected to sensors of the type InSUS 607. Mount the adapter – as shown in the photos...
M300 / M400 2G Quick Calibration Guide For pH Single-Use Sensors Type InSUS 307
METTLER TOLEDO InSUS™ pH sensors are analog, gamma irradiation-sterilizable single-use pH sensors with an integrated Pt 1000 temperature probe.

Dịch vụ

Nhanh chóng
Hỗ trợ và sửa chữa
Tuân thủ
Hiệu chỉnh và Chất lượng
Chuyên gia
Đào tạo và Tư vấn
 
 
 
 
 
 
 
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.