Material No.: 30296707
Volume Range 100 µL – 1 mL ;
Increment (electric) 1 µL ;
Volume 1 mL ;
Accuracy ± (%) (µl)1 % / 1 mL ; 1 % / 0.5 mL ; 2.5 % / 0.1 mL ;
Precision ± (%) (µl)0.4 % / 1 mL ; 0.4 % / 0.5 mL ; 1.25 % / 0.1 mL ;
Tip TechnologyLiteTouch System LTS ;High-throughput Pipette ;
Channels96 ;
Maximum Volume 1 mL ;
Quantity1 pcs ;
Material No.: 30296706
Volume Range 5 µL – 200 µL ;
Increment (electric) 0.2 µL ;
Volume
Accuracy ± (%) (µl)1 % / 200 µL ; 1 % / 100 µL ; 2 % / 20 µL ; 5 % / 5 µL ;
Precision ± (%) (µl)0.4 % / 200 µL ; 0.8 % / 100 µL ; 1.5 % / 20 µL ; 3.5 % / 5 µL ;
Tip TechnologyLiteTouch System LTS ;High-throughput Pipette ;
Channels96 ;
Maximum Volume 200 µL ;
Quantity1 pcs ;
Material No.: 30296705
Volume Range 0.5 µL – 20 µL ;
Increment (electric) 0.02 µL ;
Volume 20 µL ;
Accuracy ± (%) (µl)1 % / 20 µL ; 1.2 % / 10 µL ; 6 % / 2 µL ; 12 % / 1 µL ;
Precision ± (%) (µl)0.8 % / 20 µL ; 1 % / 10 µL ; 5 % / 2 µL ; 10 % / 1 µL ;
Tip TechnologyLiteTouch System LTS ;High-throughput Pipette ;
Channels96 ;
Maximum Volume 20 µL ;
Quantity1 pcs ;
Comparison

Documentation

Manuals

BenchSmart 96 Operating Instructions
This manual provides a complete overview of the operating instructions for the BenchSmart 96 Pipetting System.

Brochures

White Papers

Semi-Automated Pipetting - Higher Accuracy, Greater Flexibility
This whitepaper studies the capabilities and accuracy of utilizing BenchSmart 96 in the sample preparation for these two assays.

Certificates

Benchsmart 96 - Electronic Information Product (EIP) - China RoHS Substance Disclosure Statement Table
Benchsmart 96 - Electronic Information Product (EIP) - China RoHS Substance Disclosure Statement Table

Firmware and Software

BenchSmart 96 Firmware Update Instructions
This BenchSmart 96 Firmware Update Instructions provides a complete overview of the operating instructions for the BenchSmart 96 Pipetting System.
BenchSmart 96 Terminal Software Upgrade Instructions
This BenchSmart 96 Terminal Software Upgrade Instructions for the BenchSmart 96 Pipetting System.

Note: Firmware v.1.0.3.1958 must be installed before installing this Terminal (Tablet touchscreen) software. See above.

Services

800 543 4030
Call Service

Expert Service – Tailored to Fit Your Pipetting Needs

METTLER TOLEDO supports and services your pipettes through their entire life-cycle, from good pipetting techniques to preventive maintenance and calibration to equipment repair.

See It In Action

Webinars
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.