Workflow Expansion

Workflow Expansion

  • Add-on burette modules create extra titration channels on demand
  • Precision pumps automate sequential reagent dosing steps
  • I/O boards connect stirrers, sensors for multi-stage workflows
Sample Versatility

Sample Versatility

  • Sealed KF cells manage volatile, moisture-sensitive samples
  • High-temperature ovens dry viscous or solid matrices efficiently
  • Solvent-resistant electrodes tackle acids, proteins, surfactants
Capacity Boost

Capacity Boost

  • Large reagent reservoirs power overnight titrations without refills
  • Rapid-flush rinse modules clear lines in seconds, slashing downtime
  • Auxiliary dosing pumps supply parallel channels, doubling throughput
Application Enhancement

Application Enhancement

  • Application kits broaden acid-base, redox, surfactant testing
  • Specialty electrodes deliver accurate results across challenging matrices
  • RFID reagents preload factors, eliminating manual entry and easing validation

Lifecycle Support at Every Stage

Unlock Service Excellence - Maximize Your Efficiency

How can I run several titration methods that need different titrants on the same instrument without wasting time or risking mix-ups?

METTLER TOLEDO Excellence titrators solve the problem with Plug’n Play, exchangeable digital burettes (5–50 mL). Each burette carries an embedded chip that stores the titrant’s identity, concentration, lot and expiry date; the moment you lock it onto the drive, the instrument or LabX software reads those values, loads the right parameters and even blocks a run if the reagent is out of spec or overdue for re-standardization. Because every reagent gets its own dedicated dosing unit, you eliminate cross-contamination and the rinse cycles that waste time and solvent. The modular platform lets you keep multiple reagents permanently mounted, up to four burette drives on T5/T7 and eight on the flagship T9, so switching from HCl to AgNO₃ or Karl Fischer reagent is literally a click, not a teardown.

How does SmartChemicals™ RFID automate titrant data capture and protect data integrity?

A SmartChemicals reagent bottle has an RFID chip hidden under its label that stores the titrant’s identity, lot number, concentration and expiry date. The instant the chip is read on an Excellence titrator’s Smartchemical reader, or read by the SmartChemicals handheld reader, the instrument uploads that metadata automatically in the Titrator Setup, eliminating manual typing and the transcription errors that can skew results. 

LabX software links every result to that unique bottle ID, tracks time-in-service, and can block a run if the titrant has expired or its concentration is outside your SOP limits, providing an auditable trail for FDA 21 CFR 11 and ISO 17025 compliance. SmartChemicals is supported on instruments that use exchangeable digital burettes, including Excellence T-Series titrators and EVA Karl Fischer models, while EasyPlus™ systems with fixed burettes continue to rely on manual reagent verification.

How does an automated solvent-management system make Karl Fischer titrations safer and more reproducible?

An automated solvent-management module replaces the manual “open-the-cell, siphon and refill” routine with a sealed, OneClick cycle: t the solvent-pump dPump KF drains the spent methanol through PTFE lines, rinses the cell and refills it with fresh solvent, so operators never handle low-flash-point reagents or breathe toxic vapors. Because the atmosphere inside the sealed cell stays undisturbed, baseline drift falls to a predictable minimum, which in turn improves endpoint stability and extends reagent life. 

Safety and compliance are further strengthened by onboard intelligence: the system monitors bottle and waste levels with LevelSens sensors and halts the exchange before any overflow or dry-run can occur, while every solvent action is time-stamped and stored in the same LabX audit trail as the titration results, supporting 21 CFR 11 and EU Annex 11 requirements  . Whether you run an EVA V1/V3 with its standard KF Pump or an Excellence T5/T7/T9 fitted with the optional Solvent Manager, automated solvent handling delivers hands-off safety, consistent drift values and fully traceable solvent changes for every Karl Fischer determination.

How can I be sure that all the water is extracted from my oily sample? I measure lubricants oil and they tend to retain water.

When you run an InMotion™ KF Flex or Pro autosampler, which can be paired with both Excellence T7/T9 titrators and the new EVA KF instruments, the optional Long Needle for Oil Analysis, immersed in a viscous sample (e.g. Lubricant oil) helps to extract all the water from the sample. Adding the Heated Transfer Tube , that gently warms the gas flow during transport, ensure no condensation happens during the process of water transfer into the titrator’s vessel.

Because these accessories are integrated into the autosampler’s OneClick workflow, you can queue up to 120 unattended samples and keep every vial, needle and tube chemically isolated, no manual scraping or syringe cleanup, and repeatability improves noticeably on high-viscosity products.

When is a PowerShower rinse station the right choice for my METTLER TOLEDO titration setup?

If your workflow runs dozens of samples per day, especially oily, particulate-laden or viscous matrices, the time lost to manual electrode and propeller stirrer cleaning quickly becomes the production bottleneck. PowerShower, an integrated rinse module mounted on the titration stand and controlled by InMotion™ or Rondolino autosamplers, unleashes high-velocity solvent jets the moment the arm lifts, scrubbing the electrode(s)c, the stirrer, the dosing tip and temperature probe in 5–10 seconds. Because the entire sequence is automated, throughput climbs while operators stay hands-off.   

Beyond speed, the multi-angle spray greatly dilutes residual analyte and particulate films, slashing carry-over that can erode accuracy in long unattended series. Consistent, repeatable cleaning between every beaker protects endpoint integrity, reduces rework and extends sensor life, making the PowerShower investment pay for itself wherever high sample volumes or “dirty” products meet METTLER TOLEDO Excellence, EVA or other autosampler-equipped titrators.

How does the DispenSix automated liquid handler improve titration workflows compared with using a calibrated pipette?

DispenSix is a six-port, 50 mL liquid-handling module that bolts to an Excellence T7 (one unit) or T9 (two units) titrator and delivers volumes from 10 µL to 500 mL with 120 000-step (0.42 µL) resolution. The PTFE/PVDF flow path has an unbeatable ~45 µL dead volume, and every dispense meets ISO 8655-3 accuracy and precision. A built-in RFID chip identifies the liquids configured on each port, so the titrator loads the correct parameters the moment the unit is plugged in, no manual data entry, no cross-connection risk.

Once primed, the burette sweeps the loop volume into the beaker automatically, creating identical aliquots for dilution series, multi-solvent sample prep or routine QC runs. This hands-free dosing replaces repetitive pipetting, eliminates operator contact with corrosive or volatile reagents, and, because the same piston that performs the titration also handles the transfer, cuts cycle time while holding volumetric precision to ±0.05 %. The result is faster, fully traceable liquid handling that boosts throughput and consistency across even the most complex titration methods.Form

How do EasyDirect Titration Software and LabX Titration Software differ?

EasyDirect is a lightweight PC application that captures the results from up to three connected EasyPlus titrators, builds a searchable database and adds value-add tools such as curve review, one additional statistics column per instrument and flexible CSV, PDF or printed reports . Because it focuses on result archiving and basic data handling, setup is quick, simply connect the titrator via USB, and everyday tasks like tagging sample IDs or exporting batches to Excel can be done without changing your existing methods.

LabX Titration Software goes further by linking multiple METTLER TOLEDO instruments (titrators, balances, density meters, refractometers, melting-point systems and more) to a central SQL database. It offers role-based user management, electronic signatures, 21 CFR Part 11 / EU Annex 11 audit trails, locked result files and automatic tracking of titrant and sensor status, features designed to satisfy regulated-lab data-integrity requirements. LabX also stores all methods and sample series in one place, lets you start or monitor runs from either the instrument or the PC and generates tailored, compliance-ready report, providing a scalable path when laboratories need full multi-instrument control and regulatory oversight.

Our samples are difficult to dissolve in the titration medium. What can we do to ensure complete and reproducible results?

For insoluble or highly viscous matrices, EVA Karl Fischer titrators offer several extraction options. With an EVA V1 you can raise the cell temperature using a thermosettable vessel, add auxiliary solvents for internal extraction or switch to gas-phase (oven) extraction with InMotion KF Six; each approach helps transfer water into the KF solution without altering chemistry. 

When those measures are still not enough, EVA V3 accepts a rotor–stator homogenizer that disperses the sample directly in the cell.  The instrument auto-detects the homogenizer via its USB-A port; an adapter positions the shaft securely over the vessel, and a blank-correction method compensates for any water introduced during grinding. This sealed, automated homogenization step releases trapped moisture quickly and yields reliable water recoveries even in emulsions like mayonnaise, sunscreen or industrial latex.

I want to…
Need assistance?
Our team is here to help you achieve your goals! Speak with our experts.