Thermal Analysis System HP DSC 2+

DSC analyses under pressure.STARe System HP DSC 2+

Outstanding sensitivity and resolution

The HP DSC cell is based on the successful DSC technology and guarantees outstanding performance thanks to its FRS 6+ and HSS 9+ DSC sensors.

For Accelerated Materials Testing

Benefit from shorter analysis times, measurements under process conditions, higher gas concentrations and better interpretation.

Innovative high-pressure technology

The furnace is specially insulated so that no temperature gradients occur. This guarantees stable and reproducible baselines, even at high pressures.

رقم المادة: 30139240

طلب أسعار
المواصفات - Thermal Analysis System HP DSC 2+
Temperature range
22 °C – 700 °C
Pressure Range
0 MPa – 10 MPa
Heating Rate (/min)
0.1 K – 50 K

Shorter analysis times

higher pressure and temperature accelerate reactions

Measurements under process conditions

simulation of practical reaction environments

Better interpretation

effects can be separated by suppressing vaporization

Higher gas concentrations

reaction rate of heterogeneous reactions with gases is increased

Measurements under special atmospheres

oxidative, oxygen-free conditions or measurements with toxic or combustible gases are possible

High resolution, outstanding sensitivity

Measure very weak effects as well as excellent temperature resolution of close-lying effects

Comply to current standards

The HP DSC 2+ is technical compliant to current standards such as ASTM D5483, ASTM D5885, ASTM D6186, ASTM E1782

الوثائق

منشورات المنتج

HP DSC 2+ Product Brochure
Increased pressure is a factor that influences all physical changes and chemical reactions in which a change in volume occurs. For material testing, p...
Brochure: STARe Excellence Software
Thermal analysis is a well-established analytical method that is widely used in many different fields. It provides laboratories with valuable results...
The Future of Thermal Analysis Brochure
Thermal Analysis comprises a group of techniques that measure the physical or chemical properties of a sample as a function of temperature or time whi...

الملحقات

المواد الاستهلاكية

البوتقات الذهبية للتحليل الحراري

Set of 6 gold crucibles with lids. The gold pan is chemically resistant. Apart from some types of the aluminum pans, it is the only pan that can be hermetically sealed by cold welding. The maximum permissible pressure is 0.25 MPa.

رقم المادة: 27220

Set of gold plated Aluminum crucibles with lids. The set includes 10 pans and lids. The gold plated aluminum crucible is chemically resistant and can be hermetically sealed through cold welding. The maximum permissible pressure is 0.2 MPa.

رقم المادة: 51142973

بوتقات الضغط المرتفع للتحليل الحراري

Set of 25 crucibles, lids and seals. The medium pressure crucible is sealed with a FPM O-ring. The maximum pressure is 2 MPa. The crucible can also be sealed without using an O-ring (self-generated atmosphere).

رقم المادة: 26929

Set of 25 crucibles, lids and seals. The medium pressure crucible is sealed with a FPM O-ring. The maximum pressure is 2 MPa. The crucible can also be sealed without using an O-ring (self-generated atmosphere).

رقم المادة: 29990

Set of 3 crucibles with screw caps and seals. This light and flat crucible gives, compared to the larger high pressure crucibles, better DSC signals. After the measurement, the crucible can be opened, cleaned and reused about 20 times.

رقم المادة: 51140404

Set of 3 gold-plated crucibles with screw caps and seals. This light and flat crucible gives, compared to the larger high pressure crucibles, better DSC signals. After the measurement, the crucible can be opened, cleaned and reused about 20 times.

رقم المادة: 51140405

Set of 25 crucibles (without pin), lids and rupture disks. The gold-plated steel crucibles have proven highly effective in the field of safety investigations. They can only be used for one measurement each. The maximum pressure is 15 MPa.

رقم المادة: 30077139

Set of 25 crucibles (without pin), lids and rupture disks. The gold-plated steel crucibles have proven highly effective in the field of safety investigations. They can only be used for one measurement each. The maximum pressure is 15 MPa.

رقم المادة: 26731

Set of 25 crucibles (with pin), lids and rupture disks. The gold-plated steel crucibles have proven highly effective in the field of safety investigations. They can only be used for one measurement each. The maximum pressure is 15 MPa.

رقم المادة: 26732

The crucible is made of a temperature resistant NiCr TiAl alloy. The crucible can be sealed thanks to its thread using a special sealing tool. After the measurement, it can be cleaned and reused. The crucible can only be used with a furnace expander.

رقم المادة: 650072

The crucible is made of a temperature resistant NiCr TiAl alloy. The crucible can be sealed thanks to its thread using a special sealing tool. After the measurement, it can be cleaned and reused. The crucible can only be used with a furnace expander.

رقم المادة: 650066

بوتقات بلاتينية للتحليل الحراري

Set of 4 crucibles with lids. Platinum crucibles are mainly used for TGA or DSC measurements at temperatures above 640 °C. SDTA and DSC curves measured with platinum crucibles are usually better than those obtained using crucibles made of alumina.

رقم المادة: 51140842

Set of 4 crucibles with lids. Platinum crucibles are mainly used for TGA or DSC measurements at temperatures above 640 °C. SDTA and DSC curves measured with platinum crucibles are usually better than those obtained using crucibles made of alumina.

رقم المادة: 51119654

Set of 4 crucibles with lids. Platinum crucibles are mainly used for TGA or DSC measurements at temperatures above 640 °C. SDTA and DSC curves measured with platinum crucibles are usually better than those obtained using crucibles made of alumina.

رقم المادة: 24126

بوتقات من الألومنيوم للتحليل الحراري

Set of 100 crucibles with lids. This is a standard type of pan for DSC measurements – it is very shallow (low in height) and has a strong flat base (this ensures that temperature gradients are as low as possible).

رقم المادة: 26763

Set of 100 crucibles with lids. A standard type of pan for DSC measurements – very shallow, with a strong flat base (this ensures that temperature gradients are as low as possible).

رقم المادة: 27331

Set of 400 crucibles without lids. This is a standard type of pan for DSC measurements – it is very shallow (low in height) and has a strong flat base (this ensures that temperature gradients are as low as possible).

رقم المادة: 51119870

Set of 100 crucibles with lids. The light aluminum pan gives the shortest signal time constant. The pan is particularly suitable for measuring polymer films, disks and powders – the samples are pressed down tightly against the base of the pan.

رقم المادة: 51119810

Set of 100 crucibles and lids optimized for enthalpy measurements. The crucible can be hermetically sealed to suppress endothermic evaporation or vaporization when carrying out DSC measurements on volatile substances.

رقم المادة: 30085850

Set of 400 crucibles without lids. This large crucible is used for DSC measurements. It allows you to use larger quantities of sample if the signal obtained from the sample in a 40 µL pan is too weak.

رقم المادة: 51119872

Set of 400 lids specially made to be automatically pierced before the transfer into the measuring cell.

رقم المادة: 51119873

بوتقات نحاسية للتحليل الحراري

Set of 100 crucibles without lids. This type of crucible is almost exclusively used for the determination of oxidative stability (OIT). Usually the induction time measured in this way is compared with the value obtained with an inert aluminum pan.

رقم المادة: 51140407

برمجة

الحصول على عرض الأسعار
Thermal Analysis System HP DSC 2+