InTrac 779e Retractable Housing

InTrac 779e Retractable Housing

Simplifies Sensor Maintenance The InTrac 779e retractable housing is designed for industrial processes that use 12mm turbidity sensors. With a built-in flushing chamber, the electrode can be cleaned/recalibrated without interruption.

Easy Access to In-Line Sensors

The InTrac 779e offers manual or pneumatic sensor withdrawal for easy maintenance or replacement of turbidity sensors.

Highly Efficient Flushing Chamber

To ensure particles/dirt are flushed away, the InTrac 779e has a single flushing chamber to clean and calibrate the electrode with no interruptions.

Prevents Process Leaks

The safety system prevents any release of process media from the housing. Without a sensor in place, the housing cannot be inserted into the process.

Call for Quote

Specifications

Specifications - InTrac 779e Retractable Housing

Operation Retractable (Manual); Retractable (Pneumatic)
Sensors Accepted Turbidity
Wetted Parts 316 L stainless steel, Hastelloy-C22*, Titanium, PP*, PVDF*, PEEK*
O-Ring Viton®-FDA, EPDM-FDA, Kalrez®-FDA and USP Class VI
Sensor Fitting Backscatter sensors
Temperature Range (Celsius) Polypropylene: 0 to 70 °C Stainless steel: – 10 to 70 °C
Temperature Range (Farenheit) Polypropylene: 32 to 158 °F Stainless steel: 14 to 158 °F
Pressure Rating (bar) Manual: 0 to 5 bar Pneumatic: 0 to 16 bar
Pressure Rating (psig) Manual: 0 to 73 psig Pneumatic: 0 to 232 psig
Insertion Lengths 70 mm, 100 mm, 200 mm, 295 mm
Model Family InTrac 77X
Maximum Permissable Pressure (bar) Polypropylene (PP): 6 bar / 20 °C PVDF/PEEK: 6 bar / 20 °C 316 L stainless steel: 16 bar / 140 °C Hastelloy/Ti: 16 bar / 140 °C
Maximum Permissable Pressure (psig) Polypropylene (PP): 87 psig / 68 °F PVDF/PEEK: 87 psig / 68 °F 316 L stainless steel: 232 psig / 276 °F Hastelloy/Ti: 232 psig / 276 °F
Housing Length 70/100 mm: 360 mm (14.2") in process 515 mm (20.3") retracted from process 200 mm: 460 mm (18.1") in process 915 mm (36") retracted from process
Position Monitoring Options Pneumatic check (3⁄2 way valve), G 1⁄8" Inductive check, non-Ex, M12 X 1 Inductive check, Ex, M12 X 1
Pneutmatic Connections Pneutmatic Connections
Flushing Connections 2 to 6 bar (29 to 87 psig)

Ensure Process Safety & Reliability

For enhanced process safety, the InTrac 779e includes a Tri-Lock™ system to improve process reliability in harsh environments. The steel version is designed for safe operation in Ex-classified zones according to guideline ATEX 94/9/EC.

Reduce Overall Process Costs

The InTrac family of retractable housings helps to substantially reduce the operating costs of a measuring point, by allowing well-planned automatic cleaning and calibration of a sensor, which will increase its average operational life significantly.

Materials to Meet Your Environment

Multiple process connections and materials make the InTrac 779e a great choice by offering 316 L stainless steel, Hastelloy – C22, titanium, PP, PVDF, and PEEK versions for  applications in chemical, biopharmaceutical or food and beverage industries.

Documentation

Datasheets

Data Sheet: InTrac 77X e Housing
The InTrac® 776 e / 777 e / 779 e series are designed as process connections for applications with highly demanding conditions. They feature the Tri-L...
Sensor Housings Services
When O-rings leak, valves stick, and equipment fails, unplanned downtime to fix this can affect productivity and output. Regular preventive maintenanc...