Thermal Analysis System DSC 5+

The New Standard.

MultiStar™ sensor with 136 thermocouples

exceptional sensitivity for the measurement of weak effects

Power compensation

gives outstanding resolution for separation of close-lying effects

Patented electrical heat flow adjustment

saves time and provides superior accuracy

رقم المادة: 30674095

طلب أسعار

In-Depth Online Presentation of the DSC 5+

Click here to go to our in-depth online presentation of the new DSC 5+ instrument and automation options, the new MMS 1 sensor, and the AI-Powered identification and evaluation of all of types of thermal effects.

المواصفات - Thermal Analysis System DSC 5+
Temperature range
-150 °C – 700 °C
Indium peak (height to width)
25
TAWN resolution
4
TAWN sensitivity
66
Temperature precision (+/-)
0.02 K

FlexMode™ technology

choose power compensation or heat flux mode for optimal DSC performance

Time-saving FlexCal™ adjustment

guarantees accurate results under all measurement conditions

Unrivalled modular concept

tailor-made solutions for current and future needs

Wide temperature range

from -155 to 700 °C in one measurement

Robot with gas-purged sample chamber

The optional sample robot protects samples from the environment and operates reliably around the clock.

CombiCooler

This option is a combined LN2 cooling and intracooler for accessing the entire temperature range with reduced liquid nitrogen consumption.

الملحقات

خيارات التحليل الحراري وملحقاته | METTLER TOLEDO

Crucible sealing press

رقم المادة: 119410

المواد الاستهلاكية

البوتقات الذهبية للتحليل الحراري

Set of 6 gold crucibles with lids. The gold pan is chemically resistant. Apart from some types of the aluminum pans, it is the only pan that can be hermetically sealed by cold welding. The maximum permissible pressure is 0.25 MPa.

رقم المادة: 27220

بوتقات الضغط المرتفع للتحليل الحراري

Set of 25 crucibles (without pin), lids and rupture disks. The gold-plated steel crucibles have proven highly effective in the field of safety investigations. They can only be used for one measurement each. The maximum pressure is 15 MPa.

رقم المادة: 26731

بوتقات بلاتينية للتحليل الحراري

Set of 4 crucibles with lids. Platinum crucibles are mainly used for TGA or DSC measurements at temperatures above 640 °C. SDTA and DSC curves measured with platinum crucibles are usually better than those obtained using crucibles made of alumina.

رقم المادة: 51140842

بوتقات من الألومنيوم للتحليل الحراري

Set of 100 crucibles with lids. This is a standard type of pan for DSC measurements – it is very shallow (low in height) and has a strong flat base (this ensures that temperature gradients are as low as possible).

رقم المادة: 26763

Set of 400 crucibles without lids. This is a standard type of pan for DSC measurements – it is very shallow (low in height) and has a strong flat base (this ensures that temperature gradients are as low as possible).

رقم المادة: 51119870

Set of 100 crucibles with lids. The light aluminum pan gives the shortest signal time constant. The pan is particularly suitable for measuring polymer films, disks and powders – the samples are pressed down tightly against the base of the pan.

رقم المادة: 51119810

Set of 400 crucibles without lids. This large crucible is used for DSC measurements. It allows you to use larger quantities of sample if the signal obtained from the sample in a 40 µL pan is too weak.

رقم المادة: 51119872

‏بوتقات من الألومينا للتحليل الحراري

Set of 20 crucibles with lids. Alumina (aluminum oxide) crucibles are normally used for TGA measurements, above all when the TG signal, and not the SDTA signal, is important. After cleaning, these crucibles can be reused.

رقم المادة: 51140843

برمجة

الحصول على عرض الأسعار
Thermal Analysis System DSC 5+