The Challenges of Preparing Accurate Sample and Standard Concentrations

Making the Switch to Gravimetric Solution Preparation

USP 41 及 1251 章節關於天平

USP 41 及 1251 章節關於天平

確保遵守最新修訂版 2025 / 2026

了解更多

METTLER TOLEDO's Solution for Accurate Solution Preparation with Automated Solvent Dispensing

XPR自動天平

See How You Can Benefit from Automated Solvent Dispensing: An Application Example

Explore More Content

HPLC 參考標準液

準確備妥標準液

這份應用說明介紹了如何為 HPLC 及其他色層 (分析) 法,輕鬆快速地準備準確的參考標準液。

農藥殘留檢測 – 準確的標準品製備

農藥殘留檢測 – 準確的標準品製備

全球食品安全法規要求對食品、農產品和動物飼料進行農藥殘留檢測。準確的標準品製備對於檢測殘留物低於限值至關重要。

微量金屬分析

符合本效益的微量金屬分析

微量金屬分析可量化極少量的金屬。 分析這些潛在的有毒元素雜質,需要精確稱量和製備好的樣品以及參考標準液。

稱重時手動式與測重式樣品製備的比較

開始採取測重式樣品製備作法的十個理由

下載我們的指南,以瞭解手動樣品製備時可能發生的錯誤。瞭解為何應使用測重式方法的十個理由!

Daiichi Sankyo 的樣品製備

Daiichi Sankyo 的樣品製備

此篇案例研究,說明了 Daiichi Sankyo 如何透過 Quantos 的自動化粉末與液體分裝,節省分析樣品製備的時間和成本。

Frequently Asked Questions

What is gravimetric sample preparation?

Gravimetric sample preparation is weighing the sample, either manually or automated, and then delivering the required amount of solvent to achieve the desired concentration. The solvent amount is calculated automatically based on the actual amount of sample weighed, and measured by weight. Gravimetric dosing is referenced in USP chapter 1251 Weighing on an analytical balance as a type of weighing typically used for sample or standard preparation.

How can I prepare stock solutions more efficiently?

A major advantage of automated systems is that without the need of a human operator. This allows to extend the working time of your lab to 24h a day.

How can I ensure that my standard solutions are traceable?

Standard solutions are traceable when prepared on the XPR Automatic Balance because the amount of standard weighed and the amount of solvent added is recorded automatically. The resulting concentration is also calculated automatically. This information, along with all relevant metadata, is stored electronically or exported as required, making the standard preparation process fully traceable.

How can I ensure that all the steps in my analytical procedures meet compliance regulations or guidelines?

If you consider USP requirements for analytical weighing and data integrity by following the ALCOA+ framework, it is important to ensure that the balance you are using is appropriate for the amount you need to weigh out. You must respect the minimum weight specification and keep within the safe weighing range for your laboratory environment. The GWP Approved function on the XPR Automatic Balance will show you whether the minimum weight requirement is adhered to or not. For data management, the powder weighed is identified by the RFID chip in the dosing head to avoid errors, and the weight dispensed into each vial is recorded automatically and can be exported with all necessary metadata if required using LabX laboratory software. All this data is included in the audit trail for full compliance with regulations.

How do I switch from concentrations from mg/ml to mg/g?

A concentration in mg/g can be converted to mg/ml, and vice versa, using a simple density conversion (density = mass/volume). However, if a standard calibration curve is generated in mg/ml to start with, then the conversion is unnecessary because the sample concentration is measured relative to the calibration curve. 