Short description
Measurement range
عرض التفاصيل
Short descriptionConventional pH sensor with pH sensitive membrane glass
Measurement rangepH 3-10
Sensing ElementsGlass pH and Reference Electrodes, Lead-Free
Integrated Temperature ProbePt1000
Zero point7.20 ±0.25 pH
Calibration1-point process
Shaft materialsHigh density polyethylene, USP 88 class VI
O-ring materialEPDM, USP 88 class VI
Process connectionEldon James 1' port disc, with retainer
Gamma ray sterilizable25…45 kGy
Operating Temperature5…60°C (41…140°F)
Storage temperature5…25°C (41…77°F)
Mechanical pressure resistance"2 barg / 40 °C (29 psig / 104 °F), 1 barg / 60 °C (15 psig / 140 °F)"
ApprovalsUSP 88 class VI for all wetted polymer parts, factory calibration
عرض التفاصيل
Short descriptionOptical dissolved oxygen sensor
Measurement range0…250% air
Sensing ElementsOptical spot (Fluorescensce quenching)
Integrated Temperature ProbePt1000
Calibration1-point air
Shaft materialsHigh density polyethylene, USP 88 class VI
O-ring materialEPDM, USP 88 class VI
Process connectionEldon James 1' port disc
Gamma ray sterilizable25…45 kGy
Operating Temperature5…60°C (41…140°F)
Storage temperature5…25°C (41…77°F)
Mechanical pressure resistance"2 barg / 40 °C (29 psig / 104 °F), 1 barg / 60 °C (15 psig / 140 °F)"
ApprovalsUSP 88 class VI for all wetted polymer parts
المقارنة

الوثائق

Application Note

Application Note: Differences in Operation Between Analytical Multi-Use and Single-Use Sensors in Bioreactors
This application note provides information on the important trend towards the deployment of single-use bioreactors (SUBs) in the bioprocess industry....

المواصفات الفنية

Technical Data: InSUS x07 Sensor Series
The InSUS™ x07 sensor series for single-use technology bioprocesses cover the measurement parameters pH and dissolved oxygen (DO).

Instruction Manuals

Instruction Manual: InSUS Head for Optical Single-Use O₂ Sensors
These operating instructions contain all the information needed for safe and proper use of the optical sensor head.
Instruction Manual: Information for InSUS fiber optic cable
The enclosed adapter must be used, if the fiber optic cable is connected to sensors of the type InSUS 607. Mount the adapter – as shown in the photos...
M300 / M400 2G Quick Calibration Guide For pH Single-Use Sensors Type InSUS 307
METTLER TOLEDO InSUS™ pH sensors are analog, gamma irradiation-sterilizable single-use pH sensors with an integrated Pt 1000 temperature probe.

الخدمات

Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.