Čistilni sistem EasyClean 100

Čistilni sistem EasyClean 100

Avtomatizirano spiranje senzorja.EasyClean 100 smo razvili za čiščenje senzorjev, nameščenih v potopnih ohišjih. Posebej zasnovana pršilna glava curek stisnjenega zraka ali splakovalne vode usmeri v zaznavni konec senzorja.

Čiščenje v odprtih bazenih ali kanalih

EasyClean 100 poenostavlja čiščenje, saj omogoča samodejno čiščenje senzorja brez odstranjevanja senzorja in ohišja iz bazena.

Odstrani usedline, ki motijo

EasyClean 100 s čiščenjem z vodo ali stisnjenim zrakom ustvarja turbulenco, ki odpravlja delce, in tako preprečuje motnje merjenja.

Zmanjšuje potrebe po vzdrževanju

Avtomatizirano čiščenje zagotavlja zanesljivejše rezultate merjenja brez potrebe po vzdrževalnih posegih.

Št. Izdelka: 52402304

Pokličite za ponudbo

Funkcije

Čiščenje, medtem ko je senzor potopljen

Običajni načini čiščenja vključujejo odstranjevanje celotne napeljave iz bazena. Z EasyClean 100 je lahko ta postopek popolnoma avtomatiziran, ohišje in senzor pa ostaneta v potopljenem položaju.

Podaljšana življenjska doba senzorja

Nabiranje delcev na senzorju lahko povzroči napake pri branju senzorja ali skrajša življenjsko dobo senzorja. Avtomatizacija čiščenja zagotovi, da na senzorju ni nobenih ostankov in da je njegova uporabna doba daljša.

Zasnovan za potopna ohišja InDip

Ta čistilni sistem je zasnovan za integracijo s potopnimi ohišji InDip. Narejeni so iz PVC ali PVDF in so na voljo s 5-metrsko cevjo (PTFE) ter kompletom za namestitev za optimalno pritrditev na ohišje InDip.

Specifikacije

Specifikacije - Čistilni sistem EasyClean 100

Mere (VxŠxG)
220 mm x 260 mm x 80 mm
Spiranje
Da
Delovni tlak za zložljivo ohišje
-
Stopnja zaščite
IP65
Zaščita pred vdorom vode
IP65
Dovod za spiranje
2–6 barov (29–87 psig)
Čiščenje
Samo voda
Kalibracija
Ne
Dovod stisnjenega zraka
Ni
Ohišje
Jekleno ohišje s poliestrom
Parametri
pH/ORP/DO/CO2/Cond/Trb
Temperatura okolice
0 °C – 55 °C
Napajanje
100–230 VAC
50–60 hz
0,18–0,3 A
Družina modelov
EasyClean 100
Odobritve za uporabo na nevarnih območjih
Ne
Dimenzije VŠG
260 x 220 x 80 mm
Material ohišja
Jeklo s poliestrom
Sistemska integracija
Ne
Description
When taking measurements in open basins or channels, e.g. in wastewater neutralization plants, the sensor is mounted in an immersion housing type InDip550. Conventional cleaning methods involve removing the whole installation from the basin. Using EasyClean100, this procedure can be fully automated, with the housing and sensor remaining in the immersed position.

EasyClean100 consists of a control unit and a sprayhead. Air or water is sprayed directly at the tip of the electrode to ensure effective cleaning. It is therefore completely unnecessary to remove the installation from its mounted position. Cleaning is carried out automatically through actuation of the wash contact in the associated transmitter.
The sprayhead is directly mounted at the lower end of an InDip550 immersion housing. It is available made of PVC or PVDF and is delivered with a 5 m hose (PTFE) and a mounting kit for optimal fixation at the InDip housing. The hose to connect it with the EasyClean is delivered with the system.
Features and Benefits
Efficient cleaning
  • Prevents fouling of the diaphragm and the life span of the sensor is increased substantially.
 
Regular maintenance
  • Leads to more reliable measurement results and ensures more precise control of the process.
 
Automation of the maintenance sequence
  • Reduces manpower costs to an absolute minimum.
 

Dokumentacija

Brošure o izdelkih

Preglednica

Datasheet: Cleaning System Services
Maintaining a clean sensor helps ensure accurate measurement.EasyClean™ automation systems help achieve regular sensor cleaning when needed, with mini...

Tehnične specifikacije

Technical Data for EasyClean100, 150 and 200e
Only a clean sensor can provide reliable and accurate measurement results. With our EasyClean® systems, cleaning and calibration of sensors can be ful...

Dodatki

Procesni transmiter M400

Ta 4-žični 1-kanalni transmiter izpolnjuje analitične potrebe vseh segmentov in uporablja tehnologijo Intelligent Sensor Management (ISM) za zagotavljanje napredne diagnostike senzorja pri merjenju pH-vrednosti/ORP in prevodnosti.

Št. Izdelka: 30490171

Ta dvožični transmiter M400 zagotavlja najvišjo zanesljivost in varnost procesov v nevarnih in varnih območjih. Napredna funkcija ISM omogoča napovedovalno vzdrževanje, s katerim se pomaga varčevati pri stroških in izboljšati produktivnost.

Št. Izdelka: 30025515

Večkanalni transmiter M800

Oddajnik M800 Process 1-CH
Enokanalni M800 proces je večparametrski transmiter, ki zagotavlja visoko zmogljivost, zanesljivo merjenje in nudi zmogljivost s priročnim barvnim zaslonom na dotik zagotavlja integracijo s širokim naborom senzorjev ISM in analognih senzorjev.

Št. Izdelka: 30026633

Potrošni material

Programska oprema

More Information

Zahtevajte ponudbo
Čistilni sistem EasyClean 100