Watch our videos on how to get started with EasyPlus UV/VIS spectrophotometers. Learn how to perform different measurement methods, how to quickly replace the lamp of an Easy VIS spectrophotometer, and much more!
EasyPlus UV/VIS spectrophotometers combine conventional spectrophotometry, color measurements, and water analyses within one compact instrument. The spectrophotometers are designed to facilitate your routine spectroscopic workflows, saving bench space and reducing your investment in equipment and service.
Getting Started
Unboxing Your EasyPlus UV/VIS Spectrophotometer
It is easy to get started with the new EasyPlus Spectrophotometers by METTLER TOLEDO. Simply:
- Unpack,
- Connect,
- Adjust,
and perform your first measurement in less than 5 minutes!
Installing the SQKitReader Accessory For Spectroquant Water Test Kits
Learn how to easily install the SQKit reader accessory for Spectroquant water test kits on your EasyPlus UV/VIS spectrophotometer from METTLER TOLEDO.
Simply mount the SQKitReader on the magnetic pogo pins of the EasyPlus UV/VIS spectrophotometer and fix it with the included screw. After the initialization, the Spectroquant button appears on the home screen, enabling over 150 water test methods.
Internal Barcode Reader Set SQKitReader
More about Photometric Water Testing Applications
How to Measure
How to Perform Photometric Measurements with EasyPlus UV/VIS Spectrophotometers
In this video, you will learn how to easily perform photometric measurements on your EasyPlus UV/VIS Spectrophotometer from METTLER TOLEDO.
You can easily configure and save your own methods directly to the instrument. Visual guidance on the terminal walks you through the different measurement steps.
How to Perform Scan Measurements with EasyPlus UV/VIS Spectrophotometers
Take a look at how to easy it is to perform scan measurements on your EasyPlus UV/VIS Spectrophotometer by METTLER TOLEDO.
With the scan method, a full spectrum absorbance or transmittance can be recorded. Peaks and valleys can be detected automatically by the instrument.
How to Perform Quantification with EasyPlus UV/VIS Spectrophotometers
Performing quantification measurements on your EasyPlus UV/VIS Spectrophotometer by METTLER TOLEDO is simple. They can be performed using two different types of result calculations:
- By an own formula
- Or with a calibration curve, built up by measuring standards
The configuration of both methods is described in detail within this video.
How to Perform Color Measurements with EasyPlus UV/VIS Spectrophotometers
The Easy UV offers 30 predefined color calculations in the UV and visible wavelength range. For applications only measuring in the visible region, the Easy VIS features 25 color numbers.
In this video, you will learn how to easily perform color measurements on your EasyPlus UV/VIS Spectrophotometer from METTLER TOLEDO.
Configuring a method is very simple, and each method can be adjusted individually and exported to a USB flash drive. Via the normalization parameter, all measured transmittance values can be automatically recalculated to a 10 mm path length.
How to Perform Water Testing with EasyPlus UV/VIS Spectrophotometers
In this video, you will learn how to easily perform water testing measurements with Spectroquant™ test kits on your EasyPlus UV/VIS Spectrophotometer by METTLER TOLEDO.
In this category, more than 150 predefined methods are available. Scanning the 2D barcode of a test kit with the SQKitReader™ accessory automatically starts the corresponding method.
Dobrodošli, tukaj v Švici sem v našem aplikacijskem laboratoriju Mettler Toledo. V tem videu bom razložil, kako lahko omogočite, da spektrofotometri EasyPlus UV-Vis podjetja Mettler Toledo merijo vodne testne komplete nanocolor podjetja Macherey-Nagel. Video bo tudi pokazal, kje lahko prenesete metode in kako lahko ročni čitalnik črtne kode uporabite za lažje vsakodnevno delo. Za prikaz poteka bom uporabil testni komplet COD Nano Color. Za začetek moramo najprej prenesti podatkovno zbirko metod z mc.com. Povezava je navedena pod videom. Ko je podatkovna zbirka za spektrofotometer easyVIS ali easyUV uspešno prenesena, je treba mapo razširiti in shraniti v korenski imenik USB-ključka. Vse metode za testne komplete Nanocolloid so metode za kvantifikacijo. Zato lahko želene metode uvozite v to kategorijo kvantifikacije. To storite tako, da priključite USB-ključek na instrument in odprete seznam metod, kjer boste našli gumb za uvoz/izvoz. Izberite metodo, ki jo želite prepisati, nato pa se vam prikaže seznam vseh razpoložljivih metod na USB-ključku. Izberite tisto, ki ustreza vašemu testnemu kompletu. V tem primeru bom uvozil metodo COD 985-038. Za lažji potek dela ima vsaka metoda vnaprej določeno črtno kodo za funkcijo ScanStart. ScanStart omogoča zagon metode s skeniranjem črtne kode namesto izbire metode s seznama. Poleg tega lahko čitalnik črtne kode uporabite za vnos ID-ja vzorca. Toda kje najdete črtne kode? V isti zip-datoteki metode, ki ste jo pravkar prenesli, boste našli predlogo PDF za tiskanje črtnih kod za vaše testne komplete. Tukaj bom iz spustnega seznama izbral testni komplet COD 985038. Postavitev tega dokumenta je združljiva z etiketami Avery v formatu D-N-A4 in ameriškem formatu letter, kot je prikazano tukaj. Pojdimo do tiskalnika in prevzemimo etiketo. Ko smo črtno kodo zdaj natisnili na list z etiketami, smo pripravljeni na analizo našega vzorca. Zdaj pojdimo v laboratorij in začnimo potek dela. Črtno kodo pritrjujem na pokrov škatle testnega kompleta, lahko pa jo namestite tudi na svoj SOP. Vsak testni komplet Nanocolor vsebuje opis postopka priprave vzorca na pokrovu škatle. Če sledite navodilom, ste lahko prepričani, da boste dobili natančne rezultate. Vzorec sem pripravil, korak razgradnje v termoreaktorju pa je že končan. S skeniranjem črtne kode se metoda samodejno zažene. Nato vas bodo korak za korakom vodili skozi postopek merjenja. Najprej vstavite slepi vzorec in zaprite pokrov. Ko je meritev slepega vzorca končana Pozvani boste, da vstavite vzorec. Vzorec je prikazan na zaslonu. Upam, da je bil ta video koristen pri razumevanju poteka dela za testne komplete NanoColor. Poleg tega bi želel omeniti, da je mogoče za vse vaše prilagojene metode ustvariti tudi posamezne črtne kode. To storite tako, da v zavihek urejevalnika metod, pod zavihek Splošno, v parameter »method start« dodate informacije o črtni kodi. Hvala, ker ste si ogledali ta video, in ne zamudite naših drugih videov, ki pojasnjujejo različne kategorije meritev. Skeniranje. fotometrična kvantifikacija in barvne meritve.
How to Run NANOCOLOR Water Test Kits on EasyPlus UV/VIS Spectrophotometers
In this video, we explain how you can enable METTLER TOLEDO's EasyPlus UV/VIS spectrophotometers measuring NANOCOLOR® water test kits from Macherey-Nagel. This video will also demonstrate where the methods can be downloaded and how the handheld barcode reader can be used to facilitate your daily work.
How to Use the EasyDirect™ UV/VIS Software
Learn how to take full advantage of EasyPlus UV/VIS spectrophotometers in this informative video. Connecting your instrument with the user-friendly EasyDirect UV/VIS PC software allows you to streamline your daily workflow and simplify your analysis process.
Join us as we demonstrate the benefits of using this software and guide you through the easy connection process. Make the most of your EasyPlus spectrophotometer with the EasyDirect UV/VIS PC software.
Dobrodošli v mojem aplikacijskem laboratoriju tukaj v Švici. V tem videu vam bom pokazal, kako lahko odklenete polni potencial svojih spektrofotometrov easy plus UV-Vis, tako da jih povežete s programsko opremo easy direct UV-Vis za računalnik. Naučili se boste, kako vam lahko programska oprema olajša vsakodnevno delo in kako preprosto je povezati instrumente s to programsko opremo. Začnimo s kratkim uvodom v samo programsko opremo easy Direct UV-Vis. Imamo tri glavne poglede: Instruments, Measurement Results in Methods. Pod Instruments lahko vidite seznam povezanih instrumentov, njihov status vdelane programske opreme in rezultate izvedenih metod preizkusa delovanja. Če je vdelana programska oprema vašega instrumenta zastarela, lahko najnovejšo različico prek EasyDirect prenesete na USB-ključ. V tem pogledu instrumentov imate tudi možnost določiti samodejni izvoz iz EasyDirect na mesto shranjevanja po vaši izbiri. To lahko nastavite v določenih časovnih intervalih ali vsakič, ko je nov rezultat prenesen v programsko opremo. Ta funkcija omogoča samodejni izvoz na primer v mapo, ki jo upravlja vaš lokalni povezovalni sistem. Pod measurement results lahko najdete vse rezultate, ki so bili preneseni v podatkovno bazo. Ta pogled si bomo podrobneje ogledali pozneje. Pod methods lahko shranjujete in obnavljate varnostne kopije svojih povezanih instrumentov. S to funkcijo morate metode na instrumentu definirati le enkrat. Nato lahko ustrezno varnostno kopijo obnovite tudi na drugih spektrofotometrih EasyPlus UV-Vis. Kot je bilo omenjeno prej, si boste zdaj podrobneje ogledali pogled measurement results. Na vrhu lahko izberete, za kateri instrument želite prikazati rezultate. Tukaj na levi strani najdete enake merilne kategorije kot na instrumentu. Vsaka kategorija je videti podobno: na sredini je velika tabela rezultatov, na desni strani pa dodatni paneli, ki prikazujejo podatke, specifične za posamezen vnos rezultata. Postavitev te glavne tabele lahko konfigurirate in shranite prek gumba column layout. To je treba narediti posebej za vsako kategorijo. Na glavno tabelo lahko uporabite tudi filtre. Filter za datum je tukaj na vrhu. Lahko pa filtrirate tudi v posameznem stolpcu, tako da kliknete simbol lijaka v glavi stolpca. Toliko o teoriji. Poglejmo si programsko opremo v živo. Če želite instrument dodati v programsko opremo EasyDirect UV-Vis, morate samo priključiti kabel USB/A-B od instrumenta do računalnika. Programska oprema bo samodejno zaznala novo napravo in vas vprašala, ali jo želite urediti. METRA ToLido ponuja dve različni vrsti licenc, eno za povezavo enega instrumenta in drugo za vzporedno povezavo do petih instrumentov. Po vzpostavitvi povezave morate v metodi na instrumentu aktivirati izvoz parametrov v EasyDirect. Ta parameter je v vseh kategorijah v zavihku general. Privzeto je izvoz omogočen. Takoj ko izvedete metodo, bo rezultat samodejno prenesen v podatkovno bazo easy direct. S preprostim skeniranjem želim pokazati, kako hiter je prenos in kaj lahko z podatki storite kasneje. Tukaj sem pripravil metodo scan z omogočenim izvozom parametra metode v easy direct. Takoj ko je spektralno skeniranje končano, lahko nov vnos najdemo na seznamu rezultatov programske opreme easy direct UV-Vis za računalnik. Če izberemo merilno kategorijo Scan, lahko najdemo svoj rezultat, na desni strani pa seznam vrhov in dolin, sam spekter in nekaj dodatnih informacij. Za podrobnejšo analizo spektra lahko izbiramo med dvema možnostma. Graph in spectra graphics. Pri graph bo spekter prikazan in ga lahko povečujete ter skladate spektre z večkratnim izborom vnosov. Pri spectra graph bodo spektralni podatki poslani dodatni zunanji programski opremi. S to spektroskopsko programsko opremo lahko izvajate dodatne analize, kot so iskanje vrhov ali računanje odvodov. Če redno merite barvne vzorce po različnih barvnih lestvicah, vam lahko programska oprema EasyDirect UV-Vis prihrani dragocen čas, saj lahko iz enega samega skeniranja meritve prikaže več barvnih rezultatov. Naj vam to na hitro pokažem. Tukaj imam rumenkast vzorec, za katerega želim določiti barvo po barvni lestvici Zeebold in ASTM. Meritev začnem tako, da na instrumentu zaženem pripravljeno metodo Zeebold. In na zaslonu lahko vidite spekter. Ko je meritev končana, se barvni rezultat prikaže in prenese v programsko opremo Easy-DIRECT PC. Tukaj lahko zdaj vidimo izmerjeni spekter in ustrezen barvni rezultat Zewalt. Z gumbom color scales lahko zdaj določim še dve dodatni barvni lestvici glede na glavni rezultat instrumenta. V našem primeru sem z instrumentom izmeril barvo zebra, EasyDirect pa nam bo neposredno prikazal ustrezno barvo ASTM. Zato uredimo neposredno. In kot lahko vidite, je rezultat barve AST zdaj prav tako del podatkovne baze in ga je mogoče izvoziti. Tako smo prihranili celoten merilni cikel. Upam, da je bil ta video koristen za razumevanje ključnih funkcij naše programske opreme easy direct UV-Vis za računalnik. Hvala, ker ste si ogledali ta video, in prosim, poglejte tudi naše druge video vodiče za spektrofotometre easy plus UV-Vis, ki pojasnjujejo različne merilne kategorije, fotometrijo, scan, barvne meritve in testiranje vode. Se vidimo tam.
Easy Maintenance
How to Replace the Lamp of Your Easy VIS Spectrophotometer
METTLER TOLEDO's Easy VIS Spectrophotometer operates within a wavelength range of 330 to 1,000 nm. The light source is an easy-to-replace tungsten lamp, which any operator can quickly replace within just a few minutes! Simply unscrew the screws with the supplied tool, replace the module, and close it again.
Easy VIS constantly monitors and records the usage of the lamp and prompts the user to prepare for a replacement in advance. If the Easy VIS detects that the light intensity is below a threshold, it informs the user.