Transmitter M100 SM RS-485

The M100 Sensor Mount (SM) is a single-channel transmitter for connecting ISM optical dissolved oxygen sensors to a biocontroller. The Bluetooth 4.0 interface is compatible with the PC-based and mobile versions of iSense software.

رقم المادة: 30365367

أبرز الأحداث

Straight-forward Connectivity

The M100 SM offers multiple independent interfaces: two configurable 4/20 mA analog outputs and one digital MODBUS RTU.

Clear Sensor Status Alerts

LEDs clearly indicate sensor status, alarms and warnings to ensure your sensor is working properly.

Easy Sensor Handling

ISM’s Plug and Measure feature minimizes the risk of installation trouble and simplifies sensor handling.

Simplified installation

The M100 SM is an easy to install, sensor mount transmitter for the analog or digital integration of ISM optical dissolved oxygen sensors into a biocontroller‘s programmable logic controller.

Predictive Maintenance

iSense Mobile and Bluetooth communication provide access at any time to ISM‘s predictive maintenance diagnostics. Diagnostics and other sensor data can be sent as an email from a mobile device.

Error-free Operation

Transmitter current outputs are configurable via PC or mobile device. Reconfiguring is not necessary after a sensor exchange, eliminating configuration errors.

Electronic Data Management

Configuration and calibration data are stored on the sensor. Wireless communication allows this information to be sent to iSense where it can be used for sensor management and compliance purposes.

تحديد

المواصفات - Transmitter M100 SM RS-485

Digital Inputs
0
Channels
1

التوثيق

أوراق البيانات

Datasheets for Sensor Mount Transmitter M100 SM
The M100 Sensor Mount (SM) is a single-channel transmitter. It allows the connection on biocontrollers of 1-wire ISM sensors for measuring pH, ampDO a...

Manuals

Instruction Manuals for Sensor Mount Transmitter M100 SM
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits ar...
Application Solutions for M100 Modbus Programmers Guide
This programmers guides explains general modbus informations, implemented modbus registers in M100, detailed description of the implemented Modbus re...

Bus Communication Info

M100 2XH DTM Setup V1.00.0003
HART, DTM for PACTware ™: Version 4.x

مُكَمِّلات

Sensor Calibration & Maintenance Tools

رقم المادة: 30355582

المواد الاستهلاكية

برمجة

More Information

الحصول على عرض الأسعار
Transmitter M100 SM RS-485
Hazardous Area
FM Approved
FDA
أريد أن...
Need assistance?
Our team is here to achieve your goals. Speak with our experts.