O2 Sen InPro6850iG/12/120/1611311

The InPro 6850iG/12/120/Ka is an amperometric gas-phase oxygen sensor that is suited to a wide measurement range in a broad choice of applications. This sensor uses Intelligent Sensor Management (ISM) diagnostics to reduce maintenance and downtime.

رقم المادة: 52206433

أبرز الأحداث

In-Line Gas Phase O₂ Measurement

The InPro 6850iG/12/120/Ka is designed to measure gas-phase oxygen in-line, in harsh environments and hazardous area applications.

Signal Stability & Reduced Maintenance

The 3-electrode system of the InPro 6850iG/12/120/Ka includes a platinum anode that increases signal stability and extends maintenance intervals.

Real-Time Sensor Performance Monitoring

The InPro 6850iG/12/120/Ka uses ISM technology to provide advanced diagnostics, including days until the membrane kit should be replaced.

Reliable in Harsh Processes

The InPro 6850iG/12/120/Ka offers accurate measurement between 0.1% and 100% oxygen, making it suitable for challenging applications such as off-gas monitoring or inertization in aggressive processes.

Suited to Your Process Needs

To meet the requirements of your specific application, the InPro 6850iG/12/120/Ka is 120 mm long for small to medium length installations. It uses a Kalrez® O-ring with 316L stainless steel wetted parts for broad application coverage.

Fast Sensor Replacement for More Uptime

The InPro 6850iG/12/120/Ka offers an easy-to-change membrane body and ISM Plug and Measure technology. Plug and Measure allows a sensor to be polarized and calibrated away from the process under lab conditions, and then inserted directly into the process.

Accurate, Quick Measurement

The InPro 6850iG/12/120/Ka responds very quickly to oxygen levels changes (90% in less than 20 seconds), and the membrane is insensitive to dust and moisture. This provides fast, accurate readings in the process stream.

تحديد

المواصفات - O2 Sen InPro6850iG/12/120/1611311

Sensor Length
120 mm
Detection limit
300 ppm
Measuring Temp. Range
0 °C – 70 °C
Mechanical Temp. Range
-5 °C – 121 °C
Mechanical Temperature Resistance (Celsius)
-5 °C – 121 °C
Measured Pressure Resistance
0.2 bar – 9 bar
Mechanical Temperature Resistance (Fahrenheit)
23 °F – 250 °F
KALREZ is a registered trademark of E. I. Du Pont de Nemours and Company Corporation

التوثيق

White Papers

Process Instrumentation
pH/ORP (Redox) Probes, Oxygen, CO₂, Ozone Sensors, Bioburden, Total Organic Carbon, Gas, Sodium, Silica and Chloride/Sulfate Analyzers, Transmitters

مُكَمِّلات

Sensor Calibration & Maintenance Tools

رقم المادة: 52300383

المواد الاستهلاكية

برمجة

More Information

الحصول على عرض الأسعار
O2 Sen InPro6850iG/12/120/1611311
FDA
USP Class VI
أريد أن...
Need assistance?
Our team is here to achieve your goals. Speak with our experts.