DO Sensor InPro6850i/12/70

Oxygen Probe for Sterile Conditions.The InPro 6850i dissolved oxygen sensor with 12mm diameter body provides maximum accuracy and ultimate cleanability for large and small vessels with limited space or containers with smaller volumes. ISM diagnostics optimize maintenance decisions and sensor lifetime.

Sensor for Hygienic Applications

The sensor has been developed to comply fully with the EHEDG and FDA flat-surface recommendations for extremely high-level hygienic applications.

Durable and Hygienic Design

The 316L stainless steel construction allows for CIP, steam sterilization or autoclaving in place. The sensor finish eliminates process contamination.

Advanced Predictive Diagnostics

This DO sensor has Intelligent Sensor Management (ISM) technology, offering easier calibration and predictive diagnostics to reduce maintenance.

رقم المادة: 52206118

طلب أسعار
المواصفات - DO Sensor InPro6850i/12/70
Sensor Length
70 mm
Mechanical Temp. Range
-5 °C – 140 °C
Design Pressure–:
12 bar
Detection limit
6 ppb
Measured Pressure Resistance
0.2 bar – 6 bar
Measuring Temp. Range
0 °C – 80 °C

Easy to Integrate

The InPro 6850i DO sensor is easy to integrate into your process. Its watertight K8S connector (IP68) helps ensure reliable measurements.

Long Membrane Life

Ingold's PTFE/silicone membranes have been designed with an internal steel mesh that makes the membrane more rugged and dramatically increases membrane life.

Modular Design Saves Time and Money

Replacement of the anode/cathode assembly has been made simple with state-of-the-art interior sensor design, thereby reducing maintenance costs. No complicated service procedures: the quick-disconnect interior body can be replaced in less than 5 minutes.

High Process Safety

The FDA-compliant materials of construction and the easy-to-clean hygienically polished N5 grade surface finish satisfy regulatory requirements.

الوثائق

أوراق البيانات

Data Sheet: InPro 6850i Oxygen Sensor
The InPro® 6850 i dissolved oxygen sensor provides best-in-class startup time combined with maximum accuracy and high cleanability. The sensor is suit...

المواصفات الفنية

White Papers

Corrosion reduction
This white paper provides educational content and shares practical expertise on corrosion and corrosion reduction in the chemical industry. It explain...

دراسات الحالة

Reliability in CHO Cell Culture Case Study
This case study examines what led a US biotech company to choose METTLER TOLEDO solutions in order to achieve high performance pH and DO monitoring.

الملحقات

المواد الاستهلاكية

برمجة

الحصول على عرض الأسعار
DO Sensor InPro6850i/12/70
FDA
USP Class VI