الأقطاب الكهربية الانتقائية للأيونات: لنطاق واسع من تطبيقات الأقطاب الكهربية الانتقائية للأيونات

الأقطاب الكهربية الانتقائية للأيونات

Wide Range of Ion-Selective Electrodes (ISE)

METTLER TOLEDO offers a wide range of ion-selective electrodes (ISE) to meet the various range of measureable ions. Our sensors are modular in design and offer a completely integrated reference system that gives you an all-in-one solution without needing and additional reference electrode. Finally, our Click and Clear™ junction technology allows for optimal contact of the electrolyte solution and sample.

 

PerfectION™ Technology

PerfectION™ ion selective combination electrodes guarantee precision and easy handling. With the Click and Clear™ reference junction, stable and drift-free readings are assured, even in dirty or viscous samples.

 
 

Modular and Versatile

Ion-Selective half-cells consist of a universal shaft and ion-specific module that can be exchanged to measure different kinds of ions.

 
 

المقاييس

pH Meters

تلبيةً لاحتياجاتك المرتبطة بنظام الكيمياء الكهربية، فإننا نقدم مجموعة متنوعة من المقاييس الاحترافية والمتينة المعدة للاستعمال فوق الطاولة والمحمولة. تضم المجموعة التي نوفرها منتجات مصممة لأغراض الامتثال أو القياسات الروتينية أو لأي شخص يعتمد على ميزانية محدودة.

مقاييس معدة للاستعمال فوق الطاولةمقاييس محمولة

المحاليل

pH Solutions

توفر METTLER TOLEDO مجموعة شاملة عالية الجودة من المحاليل المعيارية المنظمة والمحاليل العيارية ومحاليل الإلكتروليت ومحاليل التنظيف والتحقق من الصحة لتحديد الأس الهيدروجيني والتوصيلية الكهربية وتركيز الأيونات  وجهد الأكسدة والاختزال والأكسجين المذاب. وتتوفر جميع المحاليل في زجاجات صغيرة الحجم إما في حزم أو أكياس فردية أو للاستخدام لمرة واحدة.

مزيد من المعلومات حول المحاليل

الصيانة

Service for pH meters and sensors

نوفر حزم صيانة مختلفة حسب احتياجاتك. وتتراوح هذه الحزم من التركيب والتكوين في الموقع باحترافية إلى توثيق أدلة الامتثال. إذا كنت ترغب في الحصول على تغطية كاملة تتجاوز الضمان الأولي، فنحن نقدم حزمة رعاية موسَّعة في شكل الصيانة الوقائية والإصلاح.

تعرَّف أكثر على الصيانة
 
Analytical Instruments

المنتجات والمواصفات

 
المنتجات والمواصفات
المرشح:
Set filter
مسح الكل
 
Connector
Type of junction
Shaft Material
Sensor Type
Type of membrane
رقم المادة: 51344700
عرض التفاصيل
ConnectorBNC
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonSilver/Sulfide
رقم المادة: 51344800
عرض التفاصيل
ConnectorLemo
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonSilver/Sulfide
رقم المادة: 51344703
عرض التفاصيل
ConnectorBNC
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membranePolymer
IonCalcium
رقم المادة: 51344803
عرض التفاصيل
ConnectorLemo
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membranePolymer
IonCalcium
رقم المادة: 51344706
عرض التفاصيل
ConnectorBNC
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonChloride
رقم المادة: 51344806
عرض التفاصيل
ConnectorLemo
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonChloride
رقم المادة: 51344709
عرض التفاصيل
ConnectorBNC
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonCyanide
رقم المادة: 51344809
عرض التفاصيل
ConnectorLemo
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonCyanide
رقم المادة: 51344712
عرض التفاصيل
ConnectorBNC
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonCupric
رقم المادة: 51344812
عرض التفاصيل
ConnectorLemo
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonCupric
رقم المادة: 51344715
عرض التفاصيل
ConnectorBNC
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonFluoride
رقم المادة: 51344815
عرض التفاصيل
ConnectorLemo
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonFluoride
رقم المادة: 51344718
عرض التفاصيل
ConnectorBNC
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonIodide
رقم المادة: 51344818
عرض التفاصيل
ConnectorLemo
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonIodide
رقم المادة: 51344721
عرض التفاصيل
ConnectorBNC
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membranePolymer
IonPotassium
رقم المادة: 51344821
عرض التفاصيل
ConnectorLemo
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membranePolymer
IonPotassium
رقم المادة: 51344724
عرض التفاصيل
ConnectorS7
Type of junctionCeramic
Shaft MaterialGlass
Sensor TypeCombined electrode
Type of membraneNa+-Glass
IonSodium
رقم المادة: 51344727
عرض التفاصيل
ConnectorBNC
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membranePolymer
IonNitrate
رقم المادة: 51344827
عرض التفاصيل
ConnectorLemo
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membranePolymer
IonNitrate
رقم المادة: 51344730
عرض التفاصيل
ConnectorBNC
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonLead
رقم المادة: 51344830
عرض التفاصيل
ConnectorLemo
Type of junctionClick & Clear™
Shaft MaterialEpoxy
Sensor TypeCombined electrode
Type of membraneSolid state
IonLead
رقم المادة: 51341000
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPPS
Sensor TypeHalf-cell
Type of membranePolymer
IonAmmonia (gas)
رقم المادة: 51107673
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM/PVC
Sensor TypeHalf-cell
Type of membranePolymer
IonLithium
رقم المادة: 51340900
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM/PVC
Sensor TypeHalf-cell
Type of membranePolymer
IonAmmonium
رقم المادة: 51340500
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM
Sensor TypeHalf-cell
Type of membraneSolid state
IonFluoride
رقم المادة: 51340263
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialGlass
Sensor TypeHalf-cell
Type of membraneNa+-Glass
IonSodium
رقم المادة: 51107684
عرض التفاصيل
ConnectorS7
Shaft MaterialPOM/PVC
Sensor TypeHalf-cell
Type of membranePolymer
IonMagnesium
رقم المادة: 51107681
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM
Sensor TypeHalf-cell
Type of membraneSolid state
IonCyanide
رقم المادة: 51107675
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM
Sensor TypeHalf-cell
Type of membraneSolid state
IonSulfide
رقم المادة: 51340400
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM
Sensor TypeHalf-cell
Type of membraneSolid state
IonChloride
رقم المادة: 51340700
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM/PVC
Sensor TypeHalf-cell
Type of membranePolymer
IonPotassium
رقم المادة: 51340600
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM/PVC
Sensor TypeHalf-cell
Type of membranePolymer
IonCalcium
رقم المادة: 51107870
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM
Sensor TypeHalf-cell
Type of membraneSolid state
IonThiocyanate
رقم المادة: 51340800
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM/PVC
Sensor TypeHalf-cell
Type of membranePolymer
IonNitrate
رقم المادة: 51107678
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM
Sensor TypeHalf-cell
Type of membraneSolid state
IonCopper
رقم المادة: 51340300
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM
Sensor TypeHalf-cell
Type of membraneSolid state
IonBromide
رقم المادة: 51107676
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM/PVC
Sensor TypeHalf-cell
Type of membranePolymer
IonFluoroborate
رقم المادة: 51107672
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM/PVC
Sensor TypeHalf-cell
Type of membranePolymer
IonCadmium
رقم المادة: 51107680
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM
Sensor TypeHalf-cell
Type of membraneSolid state
IonIodide
رقم المادة: 51107674
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM/PVC
Sensor TypeHalf-cell
Type of membranePolymer
IonBarium
رقم المادة: 51107873
عرض التفاصيل
ConnectorS7
Type of junction--
Shaft MaterialPOM/PVC
Sensor TypeHalf-cell
Type of membranePolymer
IonLead
المقارنة

الوثائق

منشورات المنتج

حساسات InLab®
إن تصنيع الحساسات عالية الجودة ذات الأداء المتميز لا يتطلب فقط المهارات والخبرات الفنية، بل يتطلب أيضًا فهمًا عميقًا لاستعمالات العملاء المختلفة ومتطل...

الكفاءة

قطب الفلوريد الكهربي الانتقائي للأيونات
قم بتنزيل نسخة مجانية من دليل تطبيقات قطب الفلوريد الكهربي الانتقائي للأيونات، واطلع على المزيد من المعلومات حول النظرية والمبدأ والمعايرة لهذا النوع...
دليل القطب الكهربي الانتقائي للأيونات
احصل على نسخة مجانية من دليل القطب الكهربي الانتقائي للأيونات، واطلع على نصائح وتلميحات مفيدة لاستعمالات محددة للقطب الكهربي الانتقائي للأيونات (ISE)...

الخدمات

استكشف خدماتنا - المُفصَّلة لتلائم أجهزتك

‏نقدم الدعم والخدمة لجهاز القياس الخاص بك على مدى دورة حياته بالكامل، بدءًا من التركيب مرورًا بالصيانة الوقائية والمعايرة حتى إصلاح الأجهزة.

الأداء
الصيانة والتحسين
التوافق
المعايرة والجودة
الخبرة
التدريب والمشورة

الأسئلة الشائعة

كيف تُخزِّن الأقطاب الكهربية الانتقائية للأيونات بشكل صحيح؟

تأتي جميع أدلة المستخدم مزودة بالمعلومات اللازمة حول التخزين قصير وطويل المدى للحساس المعني. وينبغي عمومًا تخزين الأقطاب الكهربية الانتقائية للأيونات في حالة جافة عند تخزينها لفترة طويلة.

ما وقت الاستجابة المعقول للقطب الكهربي الانتقائي للأيونات؟

يعتمد وقت الاستجابة على نوع الأيونات وتركيزها.

في حين أن أوقات الاستجابة للحساسات السريعة نسبيًا بالنسبة لـ Na+ وF- هي 1-3 دقائق مع التركيزات الأعلى، يزيد وقت الاستجابة إلى 5-10 دقائق عند القياس في نطاق حدود كشف أدنى.

حجم الأيون له تأثير مهم على سرعة القياس. ولهذا السبب تستغرق معظم الأيونات الأخرى وقتًا أطول في قياسها. بل قد يستغرق تحليل معادن ثقيلة، مثل Cu2+ أو Cd 2+ ما يصل إلى 20-30 دقيقة عند إجراء التحليل بالقرب من حد الكشف الأدنى.

يُعد التقليب المستمر بلطف عند قياس الأيونات أمرًا حاسمًا لتحقيق إشارة مستقرة في أسرع وقت ممكن. يتم الوصول إلى الاستقرار بدرجة أسرع عند الانتقال من تركيز أقل إلى تركيز أعلى مقارنةً بالطريقة العكسية. ولذلك، فمن المستحسن البدء دائمًا بأقل تركيز عند المعايرة والقياس.

ما حد الكشف عن قطب كهربي انتقائي للأيونات؟

يُقاس جهد الحساس عند تركيزات مختلفة من الأيون المعني. يرسم أحدها منحنى لإشارات المللي فولت مقابل التركيز (لوغاريتمي). وعادةً ما يكون على شكل S: بالأحرى مستوٍ مع التركيزات العالية جدًا والتركيزات المنخفضة جدًا، وخطيًا غالبًا فيما بينهما. تُعرَّف حدود الكشف المحددة وفقًا للنطاق الذي يكون فيه السلوك خطيًا بدرجات متفاوتة. لجعل قطب كهربي انتقائي للأيونات (ISE) قابلاً للاستخدام في مجموعة مختلفة، يلزم تغيير سطح الغشاء (أكبر مع التركيزات الأقل)، أو استخدام مادة مختلفة انتقائية للأيونات في الغشاء.

ما متوسط العمر التشغيلي للأقطاب الكهربية الانتقائية لأيونات الصوديوم؟

القطب الكهربي الانتقائي للصوديوم هو قطب كهربي زجاجي يشبه الى حدٍ بعيد قطب الأس الهيدروجيني. وتُظهِر أقطاب الأس الهيدروجيني الزجاجية خطأً قلويًا مهملاً، ويؤدي تضخيم "الخطأ القلوي" إلى أقطاب كهربية انتقائية للصوديوم، والتي تستجيب فقط للتغيرات في تركيز أيونا الصوديوم عند قيم الأس الهيدروجيني الأعلى من 7. ولذلك، فالعمر التشغيلي للقطب الكهربي الانتقائي لأيونات الصوديوم مماثل لعمر قطب الأس الهيدروجيني، ويتأثر بعدد من العوامل (مثل درجات الحرارة المرتفعة، وقيم الأس الهيدروجيني المفرطة، إلخ.).

Know the Risk of Your pH Measurement
Join the GEP eLearning Program
Ion Selective Electrode Guide – Theory and Practice
pH Theorie Guide
How to Measure pH in Small Samples
pH Toolbox for Life Sciences
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.