Request More Information

The Impact of Accuracy

Profit margins, inventory levels, and quality management are all directly affected by the accuracy of your scale. Many business owners are shocked to discover how many full truckloads worth of goods they could be giving away over time due to legally acceptable scale errors. Most truck scales are designed only to meet the minimum legal requirements. In many cases, they are calibrated to within +/-30 kilograms (or 60 pounds) of weighing error at full truckload values - and that error will grow in the time between calibrations. That much error can have a significant negative impact on your business. Modern technological advances now empower some vehicle scales to maintain a much higher accuracy level. 

Influences on Scale Accuracy

Scale accuracy is influenced by several factors. Understanding them can help scale owners like you determine the best calibration schedule for your truck scale. All vehicle scales used for business transactions must be periodically calibrated to ensure they weigh within legal accuracy tolerances, as the accuracy of most scales drifts outside the specified ranges over time. Adequately maintaining your weighbridge reduces your overall cost of ownership and maximizes the operational life of your scale. Calibrations determine the accuracy of your scale, and accuracy impacts the profitability of your operation. 

Advanced Technology

Understanding the basic differences between types of load cells can also help you understand the nature of the weighing system. Businesses that rely heavily on their scale may benefit from upgrading or converting to a more modern load cell system.

Sam, Facility Manager

I never considered that my truck scale could give me inaccurate measurements. When I called METTLER TOLEDO to calibrate my scale, I quickly learned that I had been losing profits for months. After upgrading to POWERCELL PDX, I can finally know that my profits and my reputation are protected.

Sam, Facility Manager

Analog Load Cells

Analog load cells have been in use since the 1980s and remain relatively unchanged. They are passive devices that measure weight through minuscule changes in electrical resistance. Although they can be calibrated to meet legal-for-trade accuracy standards, they can lose accuracy between calibrations. Analog load cells are highly susceptible to factors that can disturb accuracy, such as temperature, moisture, and electrical interference.

Hydraulic Load Cells

Hydraulic load cells use fluid to transmit the force of the load on the scale to a single analog load cell. They are intended to be physically resilient but still reflect the limited accuracy of analog technology. Hydraulic systems face unique challenges, such as maintaining the purity of the hydraulic fluid. With lengthy amounts of plumbing and many connections, leaking fluid is a common source of inaccuracy.

Digital Load Cells

Digital load cells transmit information using a stream of binary data, which is more stable than the small electrical current transmitted by analog load cells. Processing of the weight information only occurs once the signals reach the scale indicator. This means that the weight readings from the scale are only as good as the weakest load cell. 

POWERCELL® Load Cells

POWERCELL load cells are active devices, that expand on the benefits of digital load cells by incorporating processing capacities at each load cell. These load cells can compensate for variables that affect weight readings using patented algorithms. The calibration procedure is also more precise; POWERCELL factory calibrations are computed digitally, with infinite coefficients. This means that the scale is much closer to "zero error" than possible with other technologies.

Visual Inspection

Preventative maintenance maximizes the life of your scale, preventing unforeseen breakdowns. After a thorough inspection, a scale condition report details the status of scale components, including the foundation, weighbridge, load cells, cables, junction box, and suspension or checking system.

Eccentricity (Shift) Test

An eccentricity test evaluates the ability of the scale to weigh the same load consistently, regardless of the placement of the load on the scale. 

Error of Indication (Linearity) Test

An error of indication test is conducted to determine how the scale is weighing along a specified range, usually from zero to a certain percentage of the scale's capacity, using certified test weights

Strain Load Test

A strain load test determines a scale's performance in use. The technician places a large load on the scale and then adds the known load of certified test weights, verifying that the weight increases by the correct value.

Repeatability Test

The repeatability test determines if a known load applied to the scale will indicate the same value each time. For each repeated weighing, the indication value is recorded and compared against the first indication.