| MP06 Pressure Reactors, Glass Vessel | MP10 Pressure Reactors, Glass Vessel | HP60-1L Pressure Reactor (on demand) | HP60 Pressure Reactors | HP100 Pressure Reactors |
| 
|  |  |  |  |
| Names | MP06-SS MP06-C22 MP06-C22, Hockey | MP10-SS MP10-C22 MP10-RTCal-SS MP10-RTCal-C22 MP10-C22, Hockey | HP60-1L | HP60-SS HP60-C22 *** | HP100-SS HP100-C22 *** |
| Article numbers | 30425617 30425618 30425619 | 30425614 30425616 30425613 30425615 | On demand | 30425620 30425621 30425624 30425625 30425622 30425623 | 30425626 30425627 30425628 30425629 30425630 30425631 | 30425632 30425633 30425636 30425637 30425634 30425635
|
| Working Volume | 1.2 L | 1.2 L | 1.2 L | 1.8 L | 1.8 L |
| Operating Volume | Heat Flow Calorimetry (HFCal) 0.3...1.0 L | Heat Flow Calorimetry (HFCal) 0.3...1.0 L (HFCal with Hockey Sensor 0.25...1.0 L) | Heat Flow Calorimetry (HFCal) 0.25...1.1 L | Heat Flow Calorimetry (HFCal) 0.5...1.5 L | Heat Flow Calorimetry (HFCal) 0.5...1.5 L |
| Temperature Range | -20 °C to 200 °C | HFCal: -20 °C to 200 °C RTCal: -20 °C to 165 °C | -10°C to 250/300 °C | -10 °C to 250/300 °C | -10 °C to 250/300 °C |
| Max Working Pressure | 6 bar rel. (±10% depending on temperature)
| 6 bar rel. (±10% depending on temperature)** | 60 bar rel. (±10% depending on temperature) | 60 bar rel. (±10%depending on temperature) | 100 bar rel. (±10% depending on temperature) |
| Max Operating Pressure | 5.4 bar rel. (6 bar minus 10% tolerance) | 5.4 bar rel. (6 bar minus 10% tolerance)** | 54 bar rel. (6 bar minus 10% tolerance) | 54 bar rel. (6 bar minus 10% tolerance) | 90 bar rel. (6 bar minus 10% tolerance) |
| Material | Halloy C22 (all parts in contact with reaction mass, Bursting disc) Stainless steel 316 (Swagelok fittings, Manometer) Glass vessel | Halloy C22 (all parts in contact with reaction mass, Bursting disc) Stainless steel 316 (Swagelok fittings, Manometer) Glass vessel | HP60-SS Strinless steel 316 (all parts) HP60-C22 Halloy C22 (all parts in contact with reaction mass, Bursting disc) Stainless steel 316 (Swagelok fittings, Manometer)
| HP60-SS Strinless steel 316 (all parts) HP60-C22 Halloy C22 (all parts in contact with reaction mass, Bursting disc) Stainless steel 316 (Swagelok fittings, Manometer) | HP100-SS Strinless steel 316 (all parts) HP100-C22 Halloy C22 (all parts in contact with reaction mass, Bursting disc) Stainless steel 316 (Swagelok fittings, Manometer) |
| Cover Accessories | Stirrer motor | Stirrer motor | Stirrer motor | Stirrer motor | Stirrer motor |
| Bursting disc | Bursting disc | Bursting disc | Bursting disc | Bursting disc |
| Manometer | Manometer | Manometer | Manometer | Manometer |
| Anchor stirrer | Anchor stirrer | Anchor stirrer | Anchor stirrer | Anchor stirrer |
| Tr sensor | Tr sensor | Tr sensor | Tr sensor | Tr sensor |
| Calibration heater | Calibration heater | Calibration heater | Calibration heater | Calibration heater |
| Bottom Valve | Yes | No | Optional | Yes | Yes |
| Optionals | Propeller stirrer, Gas stirrer | Propeller stirrer, Gas stirrer | Propeller stirrer, Gas stirrer | Propeller stirrer, Gas stirrer | Propeller stirrer, Gas stirrer |
| Single baffle | Single baffle | Single baffle | Single baffle | Single baffle |
| PAT probe high pressure adapter | PAT probe high pressure adapter | PAT probe high pressure adapter | PAT probe high pressure adapter | PAT probe high pressure adapter |
| Digital Pressure Gauge | Digital Pressure Gauge | Digital Pressure Gauge | Digital Pressure Gauge | Digital Pressure Gauge |