具備 2/4 電極的電導率探頭
具備 2/4 電極的電導率探頭

具備 2/4 電極的電導率探頭

多功能感測器,用於監測化學、製藥和廢水中的電導率。

確保準確電導率測量
耐受困難和嚴格的環境條件
專為滿足您的製程需求而設計
隨插即測功能

產品和規格

 
產品和規格
篩選:
設定篩選
清除全部
 
設計
產業別/應用
測量 範圍
瞭解更多
設計
產業別/應用純水與超純水
測量 範圍0.02-10000 µS/cm
電極常數0.1 1/cm (nominal)
溫度範圍-10...100 °C (14...212 °F)
最大壓力(bar )34 bar (25 °C), 7 bar (95 °C)
最大壓力( psi)500 psi (77 °F), 100 psi (203 °F)
Sensor materialPVDF
O型環,絕緣Viton® (FDA), PEEK (FDA)
Temperature accuracy±0.25 °C at 25 °C
溫度感測器Pt1000
瞭解更多
設計SS316L
產業別/應用純水與超純水
測量 範圍0.02-10000 µS/cm
電極常數0.1 1/cm (標稱值)
溫度範圍-10...100 °C (14...212 °F)
最大壓力(bar )17 bar (25°C), 7 bar (95°C)
最大壓力( psi)250 psi (77 °F), 100 psi (203 °F)
Sensor materialSS 316L/1.4435
O型環,絕緣Viton® (FDA), PEEK (FDA)
Temperature accuracy±0.25 °C at 25 °C
溫度感測器Pt1000
瞭解更多
設計SS316L
產業別/應用製藥衛生級設計
測量 範圍0.02-2000 µS/cm
電極常數0.1 1/cm (標稱值)
溫度範圍-10...120 °C (14...248 °F)
最大壓力(bar )17 bar (25°C), 7 bar (95°C)
最大壓力( psi)250 psi (77 °F), 100 psi (203 °F)
Sensor materialSS 316L/1.4435
O型環,絕緣PEEK (FDA)
Temperature accuracy±0.25 °C at 25 °C
溫度感測器Pt1000
瞭解更多
設計Ti
產業別/應用純水系統
測量 範圍0.02-10000 µS/cm
電極常數0.1 1/cm
溫度範圍-10...100 °C (14...212 °F)
最大壓力(bar )17 bar (25 °C), 7 bar (95 °C)
最大壓力( psi)250 psi (77 °F), 100 psi (203 °F)
Sensor material塗有特氟隆的SS 316/1.4401
O型環,絕緣氟橡膠(FDA),PEEK(FDA)
Temperature accuracy+/- 0.25 °C
溫度感測器Pt1000
瞭解更多
設計316L (電極)
產業別/應用化學、製藥與食品飲料製程
測量 範圍0.02-500 mS/cm
溫度範圍-20...150 °C (-4...302 °F)
最大壓力(bar )0 ...20 bar at 135 °C0 ...10 bar at 150 °C
最大壓力( psi)0 ... 290 psi at 275 °F0 ... 145 psi at 302 °F
瞭解更多
設計316L
產業別/應用製藥與食品飲料製程
測量 範圍0.02-650 mS/cm
電極常數0.25 1/cm (標稱值)
溫度範圍-10...140 °C (14...284 °F)
最大壓力(bar )17 bar (25 °C), 7 bar (95 °C)
最大壓力( psi)250 psi (77 °F), 100 psi (203 °F)
Sensor materialPEEK (FDA)
O型環,絕緣PEEK (FDA)
Temperature accuracy±0.25 °C (25 °C)
溫度感測器Pt1000
瞭解更多
設計SS316L
產業別/應用CIP/SIP 控制與相位分離
測量 範圍0.02-650 mS/cm
電極常數0.25 1/cm (標稱值)
溫度範圍-10...140 °C (14...284 °F)
最大壓力(bar )17 bar (25 °C), 7 bar (95 °C)
最大壓力( psi)250 psi (77 °F), 100 psi (203 °F)
Sensor materialPEEK (FDA)
O型環,絕緣PEEK (FDA)
Temperature accuracy±0.25 °C (25 °C)
溫度感測器Pt1000
瞭解更多
設計SS316L
產業別/應用工業廢水
測量 範圍0.02-650 mS/cm
電極常數0.25 1/cm (標稱值)
溫度範圍-10...80 °C (14...176 °F)
最大壓力(bar )7 bar at 25°C
最大壓力( psi)100 psi (77 °F)
Sensor materialCPVC
O型環,絕緣CPVC
Temperature accuracy±0.25 °C (25 °C)
溫度感測器Pt1000
瞭解更多
設計SS316L
產業別/應用化學濃度測量
測量 範圍0.02-650 mS/cm
電極常數0.25 1/cm (nominal)
溫度範圍-10...140 °C (14...284 °F)
最大壓力(bar )17 bar (25 °C), 7 bar (95 °C)
最大壓力( psi)250 psi (77 °F), 100 psi (203 °F)
Sensor materialPEEK (FDA)
O型環,絕緣PEEK (FDA)
Temperature accuracy±0.25 °C (25 °C)
溫度感測器Pt1000
比較

文件

案例研究

Contamination in Power Plants
This case study explains how EPS, Serbia's state-owned power company, was planning a five-year upgrade of the water chemistry analytics equipment of t...
微流道毛細管電泳 (MCE) 技術
本個案研究揭示了微流道毛細管電泳 (MCE) 技術的優勢,以及它對電廠循環化學品監控的好處。
Pure water fabricator
This case study explains how an Indian pure water fabricator was faced with challenges during a power plant expansion project to meet the plant's qual...
Corrosion in power plants
This case study explains how the National Thermal Power Corporation (NTPC), India's largest power plant company, needed to reduce corrosion while at t...
Pure Water Analytics
This case study explains how Veolia Water Technologies was granted the building services contract for the National Graphene Institute and so turned to...

應用

pH Measurement In Low Conductivity Samples
Power plant cycle chemistry guidelines and standards specify narrow ranges of pH to minimize corrosion of highly valuable components. In addition, mak...
UniCond® ISM Sensor Calibrator Meets Pharmacopeia Calibration Requirements
The United States Pharmacopeia (USP), European Pharmacopeia (EP) and all other Pharmacopoeias set strict guidelines for water quality and test equipme...
Power Plant Conductivity Measurement In Water Treatment and Cycle Chemistry
Conductivity measurement throughout a power plant treatment system from raw water to ultrapure water has typically required a variety of sensors to sp...
Application Note: Optimized Control of Sour Water in Petrochemical Applications
Application Note - Control of sour water without damaging the pH electrode
Key In-line Analytical Measurements in Chemical Manufacturing of APIs
The application notes provide an overview of the in-line analyses of conductivity and turbidity, which are vital parameters in improving and tracking...

單張型錄

Data Sheet: Thornton ISM Sensors for M800 and M300 ISM
Digital liquid analysis sensors optimized for pure water treatment.
Data Sheet: 2e/4e UniCond Services
Expert service of critical components maximizes availability and productivity. Execution of recommended and scheduled maintenance delivers accurate sy...

服務

訂購
+886 2 269 59 688
高妥善率
支援和修理
卓越性能
保養和優化
符合規範
校正和品質
專業知識
訓練和諮詢
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.