Manage your online profile and customize your mt.com experience


The sure-fit handle, light springs and "stiction-less" sealing technology ensure smooth, light operation and reduce the risk of repetitive strain injuries. The fingerhook enables a relaxed grip.

To accommodate GLP/GMP compliance, the E4 electronic pipette makes it possible to password-protect pipette settings, protocols and service alarms. Service records, cycles and status data are completely tamper proof.

Rainin's Pipet-Lite XLS+ manual single channel pipette blends cutting-edge engineering and innovation to deliver highly reproducible results with exceptional comfort.

Service records, cycles and status data are recorded to the XLS+ pipette's embedded RFID tag and are completely tamper proof.
Reinen 360 Plus is a system for consistent, reliable liquid handling performance. So picking up a pipette and knowing it's accurate is second nature. Here at Rhythm we're trying to change the way chronic illness is treated and we couldn't imagine doing that without Reinen. Using metabolomics and multi -omics data processing, we're finding relationships between metabolic pathways and biological markers. And one of our goals is to get the tightest tolerance as possible so that way we can always provide accurate relationships between the data collection points for any patient's journey through their illness. We trust Rainin for the quality of the products, the precision, accuracy, and quality of the consumables all play a huge role in generating the highest quality data. And for me personally, the chemistry of the tips themselves. Based on my research at Stanford, when we were doing untargeted metabolomics, we would pick up signals from other brands of pipette tips. So it was an obvious choice for us to go with the Rainin Vio Clean Ultra. A product line and looking back that was the right decision Consistent reproducibility hinges on quality instruments, tips, and regular pipette calibration. Rainin pipette service is ISO 17025 certified, both for Rainin as well as non-Rainin pipettes, and uses OEM parts as recommended. But managing service is time consuming. You might have multiple labs, all kinds of pipettes, lots of users. That's why we created PipetteX, Raiden's pipette management software. PipetteX sends timely reminders for a pipette's individual calibration. And when service is complete, calibration certificates are stored automatically. Each pipette has its own service history and those records are audit ready. This system is capable of full 21C of... CFR Part 11 compliance. Being able to quickly verify our pipettes is super helpful. When it came to regular verification, we really wanted something that was quick, easy, and traceable. We use pipette X along with the smart check. We're able to do it on a weekly or bi -weekly basis so that way there's never a discrepancy in our results. If there's ever a deviation, we only have to go back a week or two to make certain that that hasn't perpetuated itself through our operations. We're doing many different analytical techniques, but one thing they share in common is that they're all about liquid handling and being able to rely on the accuracy and precision that RAINN provides has been critical. By bringing our premier lineup of pipettes and tips together in a system with regular expert service and tools to manage and even verify pipettes in the moment, Rainein 360 Plus gives you the freedom to concentrate on what you're doing. With Raina and 360+, you know you can always trust your results.
Always know your pipettes are accurate. Rainin 360+ connects precision pipettes and tips with expert calibration and tools to manage inventory, verify accuracy, and teach pipetting techniques. See how one lab trusts its research to Rainin 360+.

With the Rainin E4 XLS+ electronic single channel pipette, Rainin has set the standard for simplicity and performanace in electronic pipetting.

Made from 100% virgin polypropylene in a fully automated, Class 100,000 clean room facility, Rainin pipette tips provide excellent clarity and flexibility for accurate touch-off.

Take control of your pipette inventory with SmartStand, SmartCheck™, and PipetteX™ software.

From workflow evaluation and instrument selection to technique, ergonomics, and instrument qualification, GPP helps labs improve experimental reproducibility with liquid handling training and technical and support resources.
Single channel pipettes are available in manual and electronic models. The volume of liquid transfer, required precision and degree of repetition are factors to consider when choosing between the two. Single channel pipettes are compatible with almost all plasticware and glassware available to life science laboratories (e.g., PCR tubes, well plates, cuvettes and glass bottles).

Single-channel pipettes can be used to transfer liquids for many applications in life science due to their compact size and flexibility to adjust volumes. Single-channel pipettes can transfer any liquid sample from 1 µL to 20 mL from/to any plasticware or glassware including PCR tubes, well plates, microplates, cuvettes, flasks, petri dishes, vials, glass bottles, etc.

There are many single-channel pipettes offered on the market. But there are two reasons why Rainin single-channel pipettes are unique:

A single channel pipette is an instrument used in laboratories to move a precise amount of liquid from one container to another. “Single channel” distinguishes the pipette’s one singular channel from multichannel pipettes, which may have 6, 8, 12, 24, or even up to 96 and 384 channels. Multichannel pipettes fill columns and rows of well plates – or even entire plates simultaneously. Single channel pipettes aspirate into and dispense from a single tip.
There are manual and electronic single-channel pipettes. Manual pipettes are controlled with the thumb, and electronic pipettes are driven by a precise electronic motor.
The volume range of a single channel pipette often spans 1x–10x. For example, 0.2–2 µL, 2–20 µL, 20–200 µL etc. A pipette’s nominal volume – how people refer to it – is the largest volume it can dispense (e.g., a 2 uL, 20 uL, or 200 uL pipette for the sizes just listed.)
Volumes as low as 0.2 uL and as high as 20 mL can be aspirated and dispensed from different sizes of single channel pipettes.
Pipetting accuracy is highest at the high end of a pipette’s volume range. Because of this, it’s best to use the lowest-volume pipette that covers the volume you are pipetting. For example, a 0.2–2 µL pipette will have better accuracy specifications for pipetting 2 µL than a 2–20 µL model.
Choosing the right single channel pipette is important. Pipetting is a physical task. It is often repetitive. To reduce or eliminate injury, choose a comfortable, ergonomic pipette with low plunger forces and low tip ejection forces. Identify a reliable pipette that is built for durability, with proven sealing performance year after year from routine preventive maintenance. Using these criteria to choose a single channel pipette will help you maintain accuracy and be able to reproduce conditions – and results.
For the best accuracy, choose the lowest-volume single channel pipette that can accommodate the volume you are pipetting. For example, a 20 µL pipette is an excellent choice for pipetting 18 µL.
Finally, look for a pipette that has excellent accuracy specifications.
A good-quality single-channel pipette will feel good in the hand. If manual, it will have low plunger forces and a low force required to eject tips. A good-quality electronic single-channel pipette also feels good in the hand and adds electronic precision and repeatability.
Accuracy specifications are another measure of quality for single channel pipettes. Specifications measure a single channel pipette’s performance at given percentages of a pipette’s nominal volume. Accuracy and precision are best toward the higher end of a pipette’s volume range and become competitive between different pipette brands at the low end of the volume range. Look for the lowest variability at the lowest volume reported. Accuracy is measured by systemic error, and precision is measured by random error. The lowest error rates at the lowest volume are one sign of a quality single channel pipette.
Single channel pipettes can be used in a majority of applications that involve liquid handling. This is why a single channel pipette is one of the most common instruments in any laboratory. Researchers use single channel pipettes to raise cells, study proteins, run PCR or ELISA experiments, perform next-generation sequencing, CRISPR, drug discovery matrices and many more.
While some single channel pipettes are delivered with a tool to self-calibrate, all pipettes should receive regular expert attention from a qualified pipette service provider on a routine basis. A high-quality pipette service provider follows ISO-certified procedures, produces traceable pipette service history records, and uses manufacturer-recommended parts and lubricants in a highly controlled environment.
While developing the world's leading pipettes, Rainin also built the world's largest pipette service organization. It's part of Mettler Toledo. We calibrate and service millions of pipettes every year of all brands. All calibrations are guided and securely recorded by our global calibration software, GPSS. GPSS connects directly to Mettler Toledo analytical balances at every station from around the world. Every measurement instantly registers in GPSS, so you can be confident that all data is true and has not been altered. The resulting calibration certificates are compliant and audit ready, showing results, lab conditions and testing methods. GPSS also connects directly to PipetX pipette management, so if you're a lab using PipetX, your certificates are electronically delivered with a clear service history for every pipette. Both GPS -S and pipette -X follow 21 CFR Part 11 rules for electronic record-keeping. Our service labs are ISO 17025 certified, and our procedures follow the 2022 update to ISO 8655. Working within tight parameters for temperature, pressure, and humidity, we start with a 12-point inspection. We test the plunger, micrometer, tip ejector, and volume lock, and every pipette sealing system is tested for leaks. From decades of work on pipettes, we know three parts are vulnerable to wear. Where over time, on the seal that keeps the piston airtight, cracks can emerge. If air finds a way through, it reduces accuracy. Aerosols and vapor can corrode the piston, adding another source of variability. And the end of a pipette can get nicked and scratched, opening other small pathways for air to get through. We focus on these areas, replacing seals and any damaged parts. Each piston is cleaned and re-lubricated with a pipette. Pipeette manufacturers recommended leaper kit. Service is available on site in your laboratory, or you can efficiently mail in your pipeettes to service labs located around the globe for rapid turnaround. Use Your Pipettes of any brand are returned to you looking and performing like new, so you can keep your important research moving forward, reproducibly. Visit mt.com slash pipette dash service to compare service plans or contact a Mettler Toledo Rainin sales representative.
Single channel pipettes are available through your laboratory’s lab manager, your organization’s purchasing portal or online. A new single channel pipette should be delivered with a certificate of conformity documenting its performance prior to sale. To purchase a high-quality Rainin single channel pipette, visit mt.com/pipettes or shoprainin.com if you reside in the U.S.
These are the best practices for using a single channel pipette:
a. Choose a high-quality single channel pipette and high-quality pipette tips
b. Securely load a fresh pipette tip to ensure airtight accuracy
c. To avoid cross-contamination, use a fresh tip whenever you change liquids
d. Set the volume by dialing the micrometer above the desired volume. Then dial down to it
e. Hold the single channel pipette vertically or close to vertical while you are handling liquid
f. Aspirate and dispense at an even, moderate pace to avoid bubbling or splashing
g. Avoid over-aspirating by maintaining a fairly shallow (10 mm – 2mm) liquid insertion depth
h. Complete each dispense by touching off the pipette tip against the container wall. This makes use of liquid adhesion to pull the full dispense volume into the receiving vessel
The best way to troubleshoot issues with a single channel pipette is through a service visit either at your lab or by mail. Qualified service personnel can quickly and verifiably test performance, test for leaks, refresh lubricants and replace seals, and other parts as needed, using manufacturer-recommended components.
To test whether your single-channel pipette is performing accurately, you can use an analytical balance or Rainin SmartCheck to take gravimetric measurements. Based on liquid type and environmental factors like atmospheric pressure and temperature, you can identify whether a pipette is performing within specifications.