| Parametros | Test Kit No. | Rango | Metodo |
| Capacidad de ácido Cell Test a pH 4.3 (alcalinidad total ) | 101758 | 0.40–8.00 mmol/L | Reacción del indicador |
| Aluminio Cell Test | 100594 | 0.02–0.50 mg/L Al | Chromazurole S |
| Aluminium Test | 114825 | 0.020–1.20 mg/L Al | Chromazurole S |
| Amonio Cell Test | 114739 | 0.010–2.000 mg/L NH4-N | Azul indofenol |
| Amonio Cell Test | 114558 | 0.20–8.00 mg/L NH4-N | Azul indofenol |
| Amonio Cell Test | 114544 | 0.5–16.0 mg/L NH4-N | Azul indofenol |
| Amonio Cell Test | 114559 | 4.0–80.0 mg/L NH4-N | Azul indofenol |
| Amonio Test | 114752 | 0.010–3.00 mg/L NH4-N | Azul indofenol |
| Amonio Test | 100683 | 2.0–75.0 mg/L NH4-N | Azul indofenol |
| Amonio Test | 100683 | 5–150 mg/L NH4-N | Azul indofenol |
| AOX Cell Test | 100675 | 0.05–2.50 mg/L AOX | Oxidación a cloruro |
| Test Arsénico | 101747 | 0.001–0.100 mg/L As | Ag-DDTC |
| BOD Cell Test | 100687 | 0.5–3,000 mg/L BOD | Modificatción del método Winkler |
| Boro Cell Test | 100826 | 0.05–2.00 mg/L B | Azomethine H |
| Boro Test | 114839 | 0.050–0.800 mg/L B | Rosocianina |
| Bromuros Test | 100605 | 0.020–10.00 mg/L Br2 | S-DPD |
| Cadmio Cell Test | 114834 | 0.025–1.000 mg/L Cd | Derivada del cadión |
| Cadmio Test | 101745 | 0.0020–0.500 mg/L Cd | Derivada del cadión |
| Calcio Cell Test | 100858 | 10–250 mg/L Ca | Fenolftaleina purpura |
| CalcioTest | 114815 | 5–160 mg/L Ca | Glyoxal-bis-hydroxyanil |
| Calcio Test sensitive | 114815 | 1.0–15.0 mg/L Ca | Glyoxal-bis-hydroxyanil |
| Calcio Test | 100049 | 0.20–4.00 mg/L Ca | Phthalein derivate |
| Cloruros Cell Test | 114730 | 5–125 mg/L Cl | Hierro (III)-tiocianato |
| Cloruros Test | 114897 | 2.5–25.0 mg/L Cl | Hierro (III)-tiocianato |
| Cloruros Test | 114897 | 10–250 mg/L Cl | Hierro (III)-tiocianato |
| Cloruros Cell Test | 101804 | 0.5–15.0 mg/L Cl | Hierro (III)-tiocianato |
| Cloruros Test1 | 101807 | 0.10–5.00 mg/L Cl | Hierro (III)-tiocianato |
| Cloruros Cell Test ( cloro libre ) | 100595 | 0.03–6.00 mg/L Cl2 | S-DPD |
| Cloro Cell Test ( cloro libre + cloro total) | 100597 | 0.03–6.00 mg/L Cl2 | S-DPD |
| Cloro Test (cloro libre ) | 100598 | 0.010–6.00 mg/L Cl2 | S-DPD |
| Cloro Test (cloro libre ) | 100602 | 0.010–6.00 mg/L Cl2 | S-DPD |
| Cloro Test (cloro libre +cloro total ) | 100599 | 0.010–6.00 mg/L Cl2 | S-DPD |
| Cloro Test (cloro libre + cloro total ) | 100086 /100087/100088/100089 | 0.03–6.00 mg/L Cl2 | DPD |
| Cloro Test (cloro libre + cloro total ) | 100086/100087/100088 | 0.010–1.000 mg/L Cl2 | DPD |
| Chlorine Dioxide Test | 100608 | 0.020–10.00 mg/L ClO2 | S-DPD |
| Chromate Cell Test | 114552 | 0.05–2.00 mg/L Cr | Diphenylcarbazide |
| Chromate Cell Test (total chromium) | 114552 | 0.05–2.00 mg/L Cr | oxidacion Perocidisulfato / Difenilcarbazida |
| Chromate Test | 114758 | 0.010–3.00 mg/L Cr | Difenilcarbazida |
| Cobalt Cell Test | 117244 | 0.05–2.00 mg/L Co | Sal Nitroso-R |
| COD Cell Test | 114560 | 4.0–40.0 mg/L COD | Acido Cromosulfúrico oxidación/ determinación cromato |
| COD Cell Test | 101796 | 5.0–80.0 mg/L COD | Acido Cromosulfúrico oxidación/ determinación cromato |
| COD Cell Test | 114540 | 10–150 mg/L COD | Acido Cromosulfúrico oxidación/ determinación cromato |
| COD Cell Test | 114895 | 15–300 mg/L COD | Acido Cromosulfúrico oxidación/ determinación cromato |
| COD Cell Test | 114690 | 50–500 mg/L COD | Acido Cromosulfúrico oxidación/ determinación cromato |
| COD Cell Test | 114541 | 25–1,500 mg/L COD | Acido Cromosulfúrico oxidación/determinación cromo (III) |
| COD Cell Test | 114691 | 300–3,500 mg/L COD | Acido Cromosulfúrico oxidación/determinación cromo (III) |
| COD Cell Test | 114555 | 500–10,000 mg/L COD | Acido Cromosulfúrico oxidación/determinación cromo (III) |
| COD Cell Test | 101797 | 5,000–90,000 mg/L COD | Acido Cromosulfúrico oxidación/determinación cromo (III) |
| COD Cell Test (Hg free) | 109772 | 10–150 mg/L COD | Acido Cromosulfúrico oxidación/ determinación cromato |
| COD Cell Test (Hg free) | 109773 | 100–1,500 mg/L COD | Acido Cromosulfúrico oxidación/determinación cromo (III) |
| COD Cell Test for seawater | 117058 | 5.0–60.0 mg/L COD | Depleción de cloruro / oxidación de ácido cromofúrico / determinación de cromato |
| COD Cell Test for seawater | 117059 | 50–3,000 mg/L COD | Depleción de cloruro / oxidación de ácido cromofúrico / Cromo (III) |
| Cobre Cell Test | 114553 | 0.05–8.00 mg/L Cu | Cuprizona |
| Cobre Test | 114767 | 0.02–6.00 mg/L Cu | Cuprizona |
| Cianuros Cell Test (cianuro libre) | 102531 | 0.010–0.500 mg/L CN | Acido Barbiturico + acido piridinocarboxyiico |
| Cianuro Cell Test (cianuro libre ) | 114561 | 0.010–0.500 mg/L CN | Acido Barbiturico + acido piridinocarboxyiico |
| Cianuro Cell Test (cianuros de fácil liberación ) | 114561 | 0.010–0.500 mg/L CN | Acido Citrico / acido barbituric + acido piridinocarboxilico |
| Cianuro Test (cianuro libre ) | 109701 | 0.0020–0.500 mg/L CN | Acido Barbiturico + acido piridinocarboxyiico |
| Cianuro Test (cianuros de fácil liberación) | 109701 | 0.0020–0.500 mg/L CN | Acido Citrico / acido barbituric + acido piridinocarboxilico |
| Acido Cianurico Test | 119253 | 2–160 mg/L Cyan Acid | Triazina derivative |
| Fluoruros Cell Test | 100809 | 0.10–1.80 mg/L F | Alizarina complexona |
| Fluoruros Cell Test sensitive | 100809 | 0.025–0.500 mg/L F | Alizarina complexona |
| Fluoruros Cell Test | 117243 | 0.10–2.50 mg/L F | SPADNS (como libre ) |
| Fluoruros Test | 114598 | 0.10–2.00 mg/L F | Alizarin complexone |
| Fluoruros Test | 114598 | 1.0–20.0 mg/L F | Alizarin complexone |
| Fluoruros Test | 100822 | 0.02–2.00 mg/L F | SPADNS |
| Fluoruros Test | 117236 | 0.02–2.00 mg/L F | SPADNS (As free) |
| Formaldehido Cell Test | 114500 | 0.10–8.00 mg/L HCHO | Acido Cromotropico |
| Formaldehido Test | 114678 | 0.02–8.00 mg/L HCHO | Acido Cromotropico |
| Oro Test | 114821 | 0.5–12.0 mg/L Au | Rodamina B |
| Hydrazina Test | 109711 | 0.005–2.00 mg/L N2H4 | 4-Dimetillaminobenzaldehido |
| Peróxido de Hidrógeno Cell Test | 114731 | 2.0–20.0 mg/L H2O2 | Sulfato titanilo |
| Peróxido de Hidrógeno Cell Test sensitive | 114731 | 0.25–5.00 mg/L H2O2 | Sulfato titanilo |
| Peróxido de HidrógenoTest | 118789 | 0.015–6.00 mg/L H2O2 | Fenantrolina derivative |
| Yodo Test | 100606 | 0.050–10.00 mg/L I2 | S-DPD |
| Yodo Cell Test | 114549 | 0.05–4.00 mg/L Fe | Triazina |
| Hierro Cell Test | 114896 | 1.0–50.0 mg/L Fe (Fe (II) and Fe (III)) | 2,2’-Bipiridina |
| Hierro Test | 114761 | 0.005–5.00 mg/L Fe | Triazina |
| Hierro Test | 100796 | 0.010–5.00 mg/L Fe (Fe (II) and Fe (III)) | 1,10-Fenantrolina |
| PlomoCell Test | 114833 | 0.10–5.00 mg/L Pb | PAR |
| Plomo Test | 109717 | 0.010–5.00 mg/L Pb | PAR |
| Magnesio Cell Test | 100815 | 5.0–75.0 mg/L Mg | Fenolftaleina purpura |
| Manganeso Cell Test | 100816 | 0.10–5.00 mg/L Mn | Formaldoxima |
| Manganeso Test | 114770 | 0.010–10.00 mg/L Mn | Formaldoxima |
| Manganeso Test | 101846 | 0.005–2.00 mg/L Mn | PAN |
| Molibdeno Cell Test | 100860 | 0.02–1.00 mg/L Mo | Rojo de Brompirogalol |
| Molibdeno Test | 119252 | 0.5–45.00 mg/L Mo | Acido Mercaptoacetico |
| Monocloramina Test | 101632 | 0.050–10.00 mg/L Cl2 | Azul Indofenol |
| Nikel Cell Test | 114554 | 0.10–6.00 mg/L Ni | Dimetilglioxima |
| Nikel Test | 114785 | 0.02–5.00 mg/L Ni | Dimetilglioxima |
| Nitrato Cell Test | 114542 | 0.5–18.0 mg/L NO3-N | Nitrospectral |
| Nitrato ell Test | 114563 | 0.5–25.0 mg/L NO3-N | 2,6-Dimetilfhenol |
| Nitrato Cell Test | 114764 | 1.0–50.0 mg/L NO3-N | 2,6-Dimetilfenol |
| Nitrato Cell Test | 100614 | 23–225 mg/L NO3-N | 2,6-Dimetilfenol |
| Nitrato Test | 114773 | 0.20–20.0 mg/L NO3-N | Nitrospectral |
| Nitrato Test | 109713 | 0.10–25.0 mg/L NO3-N | 2,6-Dimetilfenol |
| Nitrato Cell Test en agua de mar | 114556 | 0.10–3.00 mg/L NO3-N | Resorcina |
| Nitrato Test en agua de mar | 114942 | 0.2–17.0 mg/L NO3-N | Resorcina |
| Nitrato Test | 101842 | 0.3–30.0 mg/L NO3-N | Reducción / Acido Benzoico derivative |
| Nitrito Cell Test | 114547 | 0.010–0.700 mg/L NO2-N | Reacción Griess |
| Nitrito Cell Test | 100609 | 1.0–90.0 mg/L NO2-N | Hierro (II)-Sulfato etillenediamo |
| Nitrito Test | 114776 | 0.002–1.00 mg/L NO2-N | Reacción Griess |
| Nitrogeno (total) Cell Test | 114537 | 0.5–15.0 mg/L N | Oxidación Peroxodisulfato / Nitrospectral |
| Nitrogeno (total) Cell Test | 100613 | 0.5–15.0 mg/L N | Oxidación Peroxodisulfato / 2,6-Dimetilfenol |
| Nitrogeno (total) Cell Test | 114763 | 10–150 mg/L N | Peroxodisulfate oxidation / 2,6-Dimetilfenol |
| Oxigeno Cell Test | 114694 | 0.5–12.0 mg/L O2 | Modificación del método Winkler |
| Oxigeno Scavengers Test | 119251 | 0.020–0.500 mg/L DEHA | FerroZine® |
| Ozono Test | 100607 | 0.010–4.00 mg/L O3 | S-DPD |
| pH Cell Test | 101744 | 6.4–8.8 | Rojo Fenol |
| Fenol Cell Test | 114551 | 0.10–2.50 mg/L C6H5OH | MBTH |
| Fenol Test | 100856 | 0.025–5.00 mg/L C6H5OH | Aminoantipirina |
| Fenol Test | 100856 | 0.002–0.100 mg/L C6H5OH | Aminoantipirina por extracción |
| Fosfato Cell Test | 100474 | 0.05–5.00 mg/L PO4-P | Azul Fosformolibdenum |
| Fosfato Cell Test | 114543 | 0.05–5.00 mg/L PO4-P | Azul Fosformolibdenum |
| Fosfato Cell Test (Fosforo total) | 114543 | 0.05–5.00 mg/L P | Oxidación Peroxodisulfato/Azul Fosformolibdenum |
| Fosfato Cell Test | 100475 | 0.5–25.0 mg/L PO4-P | Azul Fosformolibdenum |
| Fosfato Cell Test | 114729 | 0.5–25.0 mg/L PO4-P | Azul Fosformolibdenum |
| Fosfato Cell Test (Fosforo total ) | 114729 | 0.5–25.0 mg/L P | Oxidación Peroxodisulfato/Azul Fosformolibdenum |
| Fosfato Cell Test | 100616 | 3.0–100.0 mg/L PO4-P | Phosphormolybdenum blue |
| Fosfato Cell Test | 100673 | 3.0–100.0 mg/L PO4-P | Phosphormolybdenum blue |
| Fosfato Cell Test (Fosforo total ) | 100673 | 3.0–100.0 mg/L P | Peroxodisulfate oxidation/phosphormolybdenum blue |
| Fosfato Test | 114848 | 0.005–5.00 mg/L PO4-P | Azul Fosformolibdenum |
| Fosfato Test | 100798 | 1.0–100.0 mg/L PO4-P | Azul Fosformolibdenum |
| Fosfato Cell Test | 114546 | 0.5–25.0 mg/L PO4-P | Vanadatomolibdato |
| Fosfato Test | 114842 | 0.5–30.0 mg/L PO4-P | Vanadatomolibdato |
| Potasio Cell Test | 114562 | 5.0–50.0 mg/L K | Kalignost®, turbidimetrico |
| Potasio Cell Test | 100615 | 30–300 mg/L K | Kalignost®, turbidimetrico |
| Dureza Residual Cell Test | 114683 | 0.50–5.00 mg/L Ca | Fenolftaleina purpura |
| Silicato (Acido Silicico) Test | 114794 | 0.11–10.70 mg/L SiO2 | Azul Silicomolibdenum |
| Silicato (Acido Silicico)) Test | 114794 | 0.011–1.600 mg/L SiO2 | Azul Silicomolibdenum |
| Silicato (Acido Silicico)) Test | 100857 | 1.1–107.0 mg/L SiO2 | Molibdatosilicato |
| Silicato (Acido Silicico)) Test | 100857 | 11–1,070 mg/L SiO2 | Molibdatosilicato |
| Plata Test | 114831 | 0.25–3.00 mg/L Ag | Eosina / 1,10-Fenantrolina |
| Sodio Cell Test en solución de nutrientes | 100885 | 10–300 mg/L Na | Indirectamente como cloruros |
| Sulfato Cell Test | 102532 | 1.0–50.0 mg/L SO4 | Sulfato de bario, turbidimetrico |
| Sulfato Cell Test | 114548 | 5–250 mg/L SO4 | Sulfato de bario, turbidimetrico |
| Sulfato Cell Test | 100617 | 50–500 mg/L SO4 | Sulfato de bario, turbidimetrico |
| Sulfato Cell Test | 114564 | 100–1,000 mg/L SO4 | Sulfato de bario, turbidimetrico |
| Sulfato Test | 114791 | 25–300 mg/L SO4 | Tanin |
| Sulfato Test | 101812 | 0.50–50.0 mg/L SO4 | Sulfato de bario, turbidimetrico |
| Sulfato Test | 102537 | 5–300 mg/L SO4 | BSulfato de bario, turbidimetrico |
| Sulfuro Test | 114779 | 0.020–1.50 mg/L S | Dimetil-p-fenyiendiamino |
| Sulfito Cell Test | 114394 | 1.0–20.0 mg/L SO3 | Reactivo Ellman |
| Sulfito Cell Test sensitivo | 114394 | 0.05–3.00 mg/L SO3 | Reactivo Ellman |
| Sulfito Test | 101746 | 1.0–60.0 mg/L SO3 | Reactivo Ellman |
| Tensoactivo (anionico) Cell Test | 102552 | 0.05–2.00 mg/L SDAS | Azul Metileno |
| Tensoactivo(cationico) Cell Test | 101764 | 0.05–1.50 mg/L k-Ten | Azul Disulfina |
| Tensoactivo (nonionico) Cell Test | 101787 | 0.10–7.50 mg/L n-Ten | TBPE |
| Estaño Cell Test | 114622 | 0.10–2.50 mg/L Sn | Violeta Pirocatecol |
| TOC Cell Test | 114878 | 5.0–80.0 mg/L TOC | Oxidación Peroxodisulfato / Indicador |
| TOC Cell Test | 114879 | 50–800 mg/L TOC | Oxidación Peroxodisulfato / Indicador |
| Dureza total Cell Test | 100961 | 5–215 mg/L Ca | Fenolftaleina purpura |
| Acidos orgánicos volátiles Acids Cell Test | 101749 | 50–3,000 mg/L CH3COOH | Esterificación |
| Acidos orgánicos volátiles Acids Test | 101809 | 50–3,000 mg/L CH3COOH | Esterificación |
| Zinc Cell Test | 100861 | 0.025–1.000 mg/L Zn | PAR |
| Zinc Cell Test | 114566 | 0.20–5.00 mg/L Zn | PAR |
| Zinc Test | 114832 | 0.05–2.50 mg/L Zn | Cl-PAN |