Pipettes | Rainin METTLER TOLEDO Pipette, Pipette Tips | Life Sciences
Rainin Pipettes and Tips

Pipettes

Liquid Handling for the Life Sciences

 

Rainin Pipettes & Pipette Tips for Superior Pipetting Performance

Through its Rainin brand, METTLER TOLEDO is a leading provider of advanced liquid handling solutions for life scientists worldwide. We offer a w...

Through its Rainin brand, METTLER TOLEDO is a leading provider of advanced liquid handling solutions for life scientists worldwide. We offer a wide selection of ergonomic manual pipettes, electronic pipettes, multichannel pipettes, BioClean LTS and universal pipette tips and expert pipette services. It is a complete pipetting solution that we call Pipetting 360°. Our commitment to quality, innovative design and state-of-the-art production result in superior pipette products that deliver years of reliable operation. Rainin developed the LiteTouch System (LTS) to increase the accuracy and precision of pipettes while decreasing friction, making Rainin pipettes a leader in pipetting ergonomics. The risk of repetitive strain injuries (RSI) is greatly reduced when using ergonomic Rainin LTS pipettes and tips.

 

Mettler-Toledo Rainin's Good Pipetting Practice™ (GPP™) online and in-person seminars are a risk-based, comprehensive and systematic approach to maximizing pipetting accuracy and repeatability.


 

1. What is a pipette?

Pipettes are handheld instruments commonly used in academic, biotech, pharmaceutical and other labs to transfer precise amounts of liquid from one container to another. Pipettes range from very basic graduated glass tubes to sophisticated precision instruments capable of aspirating and dispensing liquid in increments as small as a fraction of a microliter. The most common pipette used in life science labs around the world is the single-channel air displacement pipette.

2. How does a pipette work?

There are two basic pipette types, positive displacement and air pipettes. Modern pipettes work with a piston-stroke principle – Liquid is measured using a piston-cylinder system in the handle of the pipette. When the piston is depressed and then slowly released, the movement of the piston creates a vacuum in the disposable pipette tip and thus draws liquid up inside the tip; this process is termed aspiration. Since the piston is a long way from the liquid sample, the air cushion between the piston and liquid can have a number of effects on the accuracy of this process, depending on the liquid type. Pressing down on the plunger that had a tip full of liquid expels the liquid out from the tip; this is termed dispensing. Positive displacement pipettes work on a similar principle, however the tip of the positive displacement system contains its own piston and hence there is a minimal air cushion between the piston (that is part of the tip) and the liquid surface. Positive displacement pipettes are commonly used for samples of high viscosity (e.g. glycerol) or high vapor pressure (e.g. volatiles like alcohol), while air-displacement pipettes can be used for a large portion of laboratory applications.   

3. What is the LTS LiteTouch System?

The LiteTouch System (LTS) is a design feature in Rainin pipette tips. LTS was invented by Rainin and provides an effort-free way to load pipette tips and reduces tip-ejection force by up to 84%. Tip ejection is the leading pipette-associated cause of repetitive strain injury (RSI). LTS also provides a greater channel-to-channel consistency in multichannel pipettes. The cylindrical pipette-shaft end and matching tip cup produce a reliable, consistent seal without excessive force. LTS tips feature a ring-shaped seal and flat, round shelf that provides a positive "stop." This stop lets the user know when the seal is made and makes it impossible to jam or pound the shaft into the tip – a common problem with conical-shaped tips that are typical with universal (UNV) pipettes.

4. Why do pipette ergonomics matter?

Pipetting is usually a repetitive activity that, when loading and ejecting tips, can involve a high level of force. As with any repetitive activity, over time, the risk of developing musculoskeletal injury, such as carpal tunnel syndrome, tendinitis and other repetitive strain injuries (RSIs) increases. While good posture and stretching can provide relief, the key to preventing injury is reducing pipetting forces. The Rainin LiteTouch System (LTS) reduces tip ejection force by up to 85%. Read more about pipetting ergonomics 

5. What are pipetting accuracy and precision?

Accuracy is the ability of a pipette to deliver the volume specified on the volume setting. In other words, the trueness of a measurement to the true value. Precision is the ability of a pipette to consistently deliver same-sized volumes of liquid over multiple aliquots. For example: a pipette can be precise with regard to dispensing the same volume time after time, yet inaccurate because it fails to dispense the correct volume. An accurate and precise pipette dispenses volumes at the intended volume with each dispense. 

6. How to pipette accurately and correctly?

The pipette, the disposable tip, and the operator form a 3-part system. Accuracy depends on the interplay of the elements in the system. More than with other lab instruments, the pipette operator has a high degree of influence on the accuracy of results. As such, it is important that operators are trained to use a pipette. There are some powerful, yet simple techniques that can greatly improve pipetting accuracy. The Rainin Pipetting Technique poster offers a good summary 

7. What is pipette calibration?

Pipette calibration refers to testing a pipette's precision and accuracy and resetting it to the manufacturer's specifications if it is out of range. The most common method of pipette calibration is the gravimetric method, which involves pipetting distilled water onto an analytical balance and weighing it to assess the accuracy of the measurement. 

Publications

Services

Order
(Toll Free) 1800 22 8884 & 1800 1028 460

Expert Service – Tailored to Fit Your Pipetting Needs

METTLER TOLEDO supports and services your pipettes through their entire life-cycle, from good pipetting techniques to preventive maintenance and calibration to equipment repair.

Good Pipetting Practice

Reduce Risk and Improve Pipetting Ergonomics

Get Better Results!

Apply the principles of GPP in your lab and everyone on your team will:

  • Understand the array of liquid handling instruments and options available
  • Know how to optimize their workflow for each of the liquid handling steps involved
  • Gain the range of pipetting skills necessary to produce reliable data
  • Appreciate how ergonomics can influence data production and their own well being
  • Recognize the risk associated with out-of-calibration pipettes and the role of routine checks vs. professional service.

Take the GPP Risk Check™

Boost the accuracy and reproducibility of your data by understanding workflow-related risks and how to mitigate them. Take five minutes to run through our GPP Risk Check and see where risks lie in your work and workflow.
 

Host a GPP Seminar

METTLER TOLEDO has a comprehensive seminar offering around GPP and risk management in pipetting. Our GPP experts will train you and your team right in your lab. Just fill in the request and we will get back to you to discuss the details.

GPP eLearning program

If you prefer to learn at your own pace, you can access our GPP seminars in online eLearning sessions. It's a great opportunity to get new users pipetting quickly, or it can be a refresher course for experienced pipette users.

 

 
 
 
 
 
 
 
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.