Need assistance?
Our team is here to achieve your goals! Speak with our experts.

Wafer Cell Adaption for GPro 500

TDL Gas Measurement in Narrow Pipes

The wafer cell process adaption for the GPro 500 tunable diode laser gas analyzer is designed for implementation in small, narrow pipes. It allows accurate measurement of O2 and other gases in pipes down to DN50 (2") without obstructing flow.

Measure Gas in Narrow Pipes, In Situ
The wafer cell adaption makes in situ gas measurement in small pipes easy. Use it with the full range of GPro 500 gas sensors for maximum versatility.

No Sampling or Conditioning System
The wafer cell adaption works without a maintenance-prone sampling or conditioning system. This removes costs and measurement downtime.

No Alignment Necessary
The wafer cell is a self-contained unit that integrates directly into the pipe. It provides accurate measurement without obstructing the gas flow.

 

Wafer Cell Adaption for GPro 500
Call for Quote
Specifications - Wafer Cell Adaption for GPro 500
Effective path length 104 mm, 110 mm, 154 mm, 164 mm, 214 mm (4.09", 4.33", 6.06", 6.46", 8.43")
Gas Measured Integrates with GPro 500 analyzers for Oxygen, CO₂, CO, HCl, H₂S, Moisture, Methane, Ammonia
Lower Detection Limit Based on analyzer chosen
Short description This process adaption connects to a GPro 500 gas analyzer for installation in narrow pipes.
Process Adaption or Sensor Process Adaption

Features and Benefits


In Situ Measurement in Small Pipes
The wafer cell adaption for the GPro 500 TDL gas analyzer provides in situ gas measurement in small pipes. The wafer cell can be installed in DN50/80/100 pipes, as well as ANSI 2"/3"/4" pipes where other types of TDL analyzers have challenges.
 
Reduced Lifecycle Maintenance Costs
A major cost of gas analyzers is their maintenance-prone sampling and conditioning systems. The regular maintenance efforts on these systems significantly increases the total cost of ownership. These systems are fully eliminated with a wafer cell analyzer.
 
Simpler Installation Planning & Effort
Many TDL gas analyzers require significant planning and effort for alignment during installation. This need is removed by the wafer cell adaption, which integrates into your pipe and has ports for purge gas, temperature, and pressure measurements.
 
Wide Variety of Applications
The wafer cell adaption offers new installation possibilities for a wide range of processes. Typical applications include monitoring off-gas to incinerators and tracking feedstock purity and dryness.

Documentation

Datasheets

Datasheet: Wafer Cell Adaption for GPro 500
The wafer cell process adaption for the GPro™ 500 tunable diode laser gas analyzer is designed for implementation in small, narrow pipes. It allows ac...

Technical Specifications

Application Notes

Process Instrumentation
pH/ORP (Redox) Probes, Oxygen, CO₂, Ozone Sensors, Bioburden, Total Organic Carbon, Gas, Sodium, Silica and Chloride/Sulfate Analyzers, Transmitters

Case Studies

Gas Analyzer - Gas Sensor
These highly reliable gas analyzers are designed to provide fast response times for a variety of gases in industrial and chemical processes. Both tuna...
Minimizing Corrosion with Fast, Robust Gas Analysis
Find out in our success story how the GPro 500 is now providing Inovyn with: Greater process confidence, high measurement accuracy, low maintenance co...

Accessories

Get Your Quote
Wafer Cell Adaption for GPro 500
FDA
USP Class VI