Single Test Weights for Scales and Balances

Single Test Weights

Wide Range of Weights with the Highest Resistance to Corrosion

Our stainless steel test weights in the design of knob weights with and without adjusting cavities as well as wire or sheet weights in the milligram range are produced from the finest quality austenitic steel which offers the highest resistance to corrosion over a weight’s lifetime. Our unique manufacturing process involves melting the steel under vacuum (class E1), final-stage electrolytic polishing, fully automated cleaning processes, and final calibration using our mass comparators.

Call for Quote
View Results ()
Filter ()

Add 1 or 2 more products to compare

Advantages

Test Weights for Balances

Test Weights for Balances

Our stainless steel test weights in the design of knob weights with and without adjusting cavities as well as wire or sheet weights in the milligram range are produced from the finest quality austenitic steel which offers the highest resistance to corrosion over a weight’s lifetime. Our unique manufacturing process involves melting the steel under vacuum (class E1), final-stage electrolytic polishing, fully automated cleaning processes, and final calibration using our mass comparators. ASTM Classes 1-4, 1mg - 20kg and OIML Classes E1, E2, F1, F2 & M1, 1mg – 20kg (50kg)

Calibration Certificate Needed?

Calibration Certificate Needed?

Monitoring the performance of your weighing equipment is typically required by standards like GMP or the internal quality assurance department. For example, if you work according to ISO 9001, documented metrological traceability is required and test weights with a certificate are necessary. Calibration certificates from a METTLER TOLEDO calibration laboratory are produced in accordance with ISO/IEC 17025 to fulfill metrological traceability requirements. However, using test weights without a calibration certificate may be acceptable in certain cases. Choose your test weights according to your specific requirements – with or without a calibration certificate.

Protection and Durability

Protection and Durability

To protect the integrity of weights and ensure a long lifetime, weights are supplied in a robust and easy-to-clean plastic container. Protective materials, including foam inserts, make them a durable solution.

Toll Free 1800 22 8884
Call Service
Service for Laboratory Balances

FAQs

Is it possible to purchase single test weights with or without a calibration certificate?

Yes, single test weights are available with or without a calibration certificate - check our portfolio of calibration weights.

Are the miligram weights (mg) sheet or wire?

It depends on a weight class. E1, E2 are always wire weights, F1 can be selected from either wire or sheet weights, F2 and M1 are always sheet weights.

What is the OIML or ASTM class range of single test weights?

OIML Classes range from E1 to M1 and ASTM Classes from 1 to 4.

Are single weights only monobloc weights or do they have an adjusting cavity?

Weights from E1, E2 Classes are always monobloc, F1 Class weights can be selected from either monobloc or with an adjustable cavity. On the other hand, F2 and M1 are always weights with an adjustable cavity.