The heart of a TGA is the balance cell. Our TGA instruments use the world’s best METTLER TOLEDO micro and ultra-micro balances. The internal calibration ring weights ensure unsurpassed accuracy. Thanks to the parallel-guided balance the position of the sample does not influence the weight measurement. Built-in user selectable automatic buoyancy compensation eliminates the need for time-consuming baseline measurements. Small samples close to the low end of the weighing range are also weighed accurately because of a low minimum weight.
By using one of the many removable sensor types the TGA/DSC 3+ simultaneously measures heat flow in addition to the weight change.
High temperature effects up to 1600 °C can be measured with a TGA equipped with the HT furnace
Raspon temperature | RT to 1100 °C |
Heating rate | 0.02 to 250 K/min |
Crucible volume | Up to 100 µL |
Dynamic weighing range | 1/5 g (depending on balance model) |
Balance resolution | 0.1/1 µg (depending on balance model) |
Weighing accuracy | 0.005% |
Weighing precision | 0.0025% |
METTLER TOLEDO ultra-micro balance – rely on the leader in balance technology | |
Wide temperature range – analyze samples from ambient temperature to 1600 °C | |
DSC heat flow measurement – for simultaneous detection of thermal effects | |
Built-in gas flow control – investigate your samples in defined atmospheres | |
Automated TGA-FTIR, TGA-MS and TGA-GC/MS systems – perform accurate evolved gas analyses using FTIR and MS | |
Robust, factory endurance-tested sample robot – operate efficiently and reliably around-the-clock | |
Modular concept protects your investment – fits to your current and future needs |
METTLER TOLEDO pruža vam korisnu podršku koja će vam pomoći da zadržite informiranost o novim otkrićima i proširite svoje znanje na sljedeće načine | |||
U našem popularnom časopisu za klijente tehničke struke korisnici i stručnjaci objavljuju članke o načinima primjene iz različitih područja.
| Raspravite teme sa stručnjacima.
|
| |
pregledavanjem naših stručnih priručnika. Pisani su za korisnike koji se bave termalnom analizom te sadrže osnovne informacije, teoriju i praksu, korisne tablice svojstava materijala i mnoge zanimljive načine primjene.
| usavršavanjem vještina o termalnoj analizi. Internetska obuka učinkovit je način za brzo i praktično učenje.
| ||
pretraživanjem naše baze podataka. Ukoliko imate pitanja o pojedinom načinu primjene,odgovor možete pronaći u bazi podataka o načinu primjene.
| Obuka u učionici i dalje je jedan od najučinkovitijih načina učenja.
| ||
informiranjem – čak i kad ste u žurbi. Pristupajte svim vrstama informacija i usluga vezanima uz termalnu analizu putem svog mobilnog uređaja. | Naši novi tehnički videozapisi objašnjavaju složene probleme koji su povezani s instrumenatima za termalnu analizu i softverom STARe. |