Reliable color determination has become a non-negotiable aspect of pharmaceutical quality control. Both the European Pharmacopoeia (Ph. Eur.) and United States Pharmacopeia (USP) feature rigorous guidelines for assessing color in raw materials, intermediates, and finished products. Yet traditional visual matching can lead to operator inconsistencies and regulatory headaches. Enter the METTLER TOLEDO UV7 Spectrophotometer, combined with LabX™ software: a modern solution that replaces guesswork with precise, documented color measurements. In this article, we explore how the Pharma Color Guide—complete with ready-to-use methods—enables labs to align with official pharmacopeial standards while improving efficiency.
![]() |
Welcome from our Mettler Toledo application lab in Switzerland. In this video I will show you how to determine the color of a sample with our UV-Vis Excellence spectrophotometers. I will demonstrate this analysis with a color determination of a battery electrolyte. As decomposition progresses, the color of the electrolyte turns yellowish. Therefore we will measure the yellowness index of the electrolyte. This parameter can be used for quality control purposes as the degree of decomposition reflects the water content within the sample. Let's start with method configuration. To create a new method, click Methods and select Scanning. All predefined color calculations are located in Scanning, even if no full spectrum is required for the color calculation. By clicking New, the method configuration is started. To unlock color calculations, you have to activate color. For scan based color scales, you can select between various illuminance and observers. Most of the time, however, illuminant C and observer 2 degree are used and do not need to be changed. By confirming the input, The method editor is shown with predefined method functions. Under spectrum evaluation, you can select the unit of the measured spectrum and some further post-processing options like smoothing and peak finding. As the y-axis is based on the transmittance spectrum, we change the unit to percent T. To calculate the color number. You have to add the method function calculation by clicking insert. The calculation can only be added after spectrum evaluation. Now we can define the name. Yellowness index. As a unit for the Uranus index, we can define Y_I. Where can you find the correct formula? By clicking on Formula, you get input a formula. Color calculations are predefined. You should navigate to the number keyboard on the top right and click C for color. Here you can find the list of all predefined color calculations. All the calculations are defined for a path lengths of 10 mm. You can select the desired color scale from this list, in this case yellowness index. The correct formula is automatically inserted. Additionally, you can define the number of decimals, for example two. Some color calculations are also predefined under result proposals. In this case the method function is automatically filled. The operator can define an upper and lower limit for the result for quality control. It is important to mention that you can add as many calculations as you want. So with only one method you can determine for example several color scales. Or get other information, like absorbance at a specific wavelength. You simply insert another calculation method function for this purpose. Last, you can define how the results should be displayed on the screen. As we have only defined one result, we define one result field and select our one yellow index from the results list. Now you can save the method and are ready to start the method by clicking start. You now have the possibility to save the method to your home screen with add to home. This will create a shortcut on the home screen and is highly recommended for frequently used methods as they can be started with one click. For this you have to define a name, for example Y-I ELECTROLYTE By saving it, you will end up on the home screen. Just click the shortcut to return to the same screen as before. Now you can define the sample ID and change the dilution and correction factor if needed. Clicking Start a second time will guide you through the workflow. First, we have to insert the blank cuvette. By clicking OK, the blank determination starts. Afterwards, we are asked to insert the sample cuvette. Again, the measurement is started by clicking OK. Measured transmission spectrum is shown on the screen. With the button calculated results you can switch between the spectrum and the calculated results, which is in this case the yellowness index of your sample. I hope this short video was helpful understanding how to set up a color measurement with our UV with excellent spectrophotometers. This analysis can also be automated with our cuvette changer for up to eight samples or for up to 303 samples with our in -motion auto sampler. Check out our automation webinar or our automation guide here. Thank you for watching this video. And don't miss our other videos explaining more measurement categories and how to get predefined methods from our application library on empty dot com.
Ph. Eur. mandates 37 reference colors; USP relies on 20 color solutions. Handling these sets manually can be cumbersome, especially when time is tight or when labs operate across multiple sites. The UV7 Spectrophotometer provides an integrated approach:
- Objective Measurements: Automation frees you from human perception pitfalls, consistently mapping each sample to official references.
- Easy Method Import: With LabX, you can download and import a single set of methods for both scales—saving hours of prep and calibration.
- Seamless Automation: Automated calculation of color differences (ΔE) eliminates manual record-keeping, boosting data integrity and audit readiness.
A Two-in-One Approach to Color Testing
One advantage of adopting the UV7 is its dual purpose: beyond color determination, it supports daily UV/Vis applications like concentration checks and purity verification. This simplifies training, cuts operating costs, and ensures reproducible results across different QC tasks. For heavily regulated products—such as injectables or specialized formulations—such consistency is key to meeting global regulatory expectations.
Conclusion
Color determination needn’t be a subjective or labor-intensive chore. By unifying Ph. Eur. and USP color standards in the UV7 Spectrophotometer, METTLER TOLEDO delivers a practical, reliable way to confirm product quality. From efficient workflows to robust data handling, labs can confidently meet stringent pharmacopeial requirements within one instrument—helping ensure every dose is safe, consistent, and compliant.
![]() |
Download the Guide
For an in-depth look at workflow setup, reference solution handling, and best practices, the Pharma Color Guide is your go-to resource. It details:
- Step-by-step method import and calibration procedures
- Strategies for aligning color measurement with compendial guidelines
- Tips for verifying data integrity under real-world lab conditions
Visit Our Color Measurement Library
Want to learn more about color science, advanced data handling, or compliant industry-specific applications? Our Color Measurement Library covers:
- Fundamentals of color theory and CIE standards
- Specialized methods for different samples and industries
- Interactive tools, case studies, and expert videos
![]() |
Anika Adams is Senior Product Manager for UV/Vis Spectrophotometers at METTLER TOLEDO, where she focuses on driving innovation and optimizing customer workflows.
With a degree in business administration and experience spanning software development, mechanical engineering, and production, Anika brings a multidisciplinary perspective to the laboratory business. Her expertise lies in automating and enhancing customer processes, ensuring both product excellence and customer satisfaction.