OEM and Machine Integration
Embed weighing directly into automatedequipment for efficient and reliable process control.
Manage your online profile and customize your mt.com experience
Browse a custom portfolio, access quotes, and manage your installed devices on our extended digital platform.
Discover a smarter way to bring reliable weighing into factory automation. The ACT300 and ACT305 weight transmitters combine fast, accurate measurements, certified industrial connectivity, Smart5TM alarms, and remote setup tools to simplify integration and support reliable operation in demanding environments.
Every second of downtime, every communication delay, and every unstable measurement can impact productivity. That's why weighing performance matters. Introducing the ACT-305 Weight Transmitter. Engineered to help manufacturers improve productivity through accurate measurements, seamless automation integration, and simplified setup and diagnostics. With resolution down to 0.1 microvolt per division and advanced anti-interference technology, the ACT-305 delivers stable weighing performance in demanding industrial environments. Intelligent filtering helps maintain fast response times while minimizing the impact of electrical noise and process disturbances. The ACT-305 is built for seamless automation connectivity, because fast measurements are only valuable if data reaches the control system without delay. Supporting PROFINET, Ethernet/IP, EtherCAT, Modbus TCP, and analog output, the ACT-305 integrates easily into a wide range of control architectures. With update rates up to 800 Hz, weighing data is transferred quickly and reliably to PLCs and automation systems for faster process control. Smart5 alarms continuously track device status and alarms, helping operators identify issues before they impact production. High EMC performance. including EMI Class B and EMS Criteria A compliance, helps ensure stable operation in electrically challenging environments. The integrated web interface enables remote configuration, monitoring, and troubleshooting from anywhere on the network. Cal-free calibration, built-in diagnostics, and exportable history logs help reduce commissioning effort and simplify maintenance. ACT305 Weight Transmitter. Combining precision weighing performance, automation-ready connectivity, integrated diagnostics, and simplified device management in a compact industrial design. Productivity made simple.
Achieve fast, stable, andaccurate measurementwith advanced anti-interference design toincrease productivity andenhance quality evenunder challenging electromagnetic noiseconditions.
Enable seamless OTnetwork connectivity up to800Hz, embedded and certified to safeguard your system and automate your operation. Connect directly to PLC and automationsystems through PROFINET, EtherNet/IP, EtherCAT, Modbus TCP, or analog output.
Ensure reliable, efficient operations with Smart5TM alarming combined with advanced software and hardware for real-time issue detection, comprehensive data management, and stable measurements.
Simplify your operations with easy configuration and troubleshooting through remote access and device management, expert webserver setup assistance, and detailed error monitoring and maintenance support to prevent downtime.

Embed weighing directly into automatedequipment for efficient and reliable process control.

Improve inventory visibility and control with accurate level and inventory monitoring.

Conduct accurate dosing, batching, and filling operations with fast, stable weight data.


Alright, so when we first start working with the ACT305, the easiest way to work with it is going to be using the web server. So if I look in the manual, I can see that I'm supposed to go to the web browser of my choice. In this case, it's Microsoft Edge, and I'm supposed to just type in the IP address for the ACT305 web server, which you can see here, 192.168.0.8. When I do that here on my computer, it doesn't reach any page. It doesn't get there. And that's because, like with many people, I have my laptop set up for the IP address to DHCP. So it's never going to be on this same network. So what I'm going to do is I'm going to go to the settings of my computer. This is in Windows 11. It might look a little bit differently for you if you're using something else. But I can go to then Ethernet. And then I want to look at my I assignment O let's go ahead and edit that and I'm going to select manual instead of automatic and it's going to be IV4. So here I need to use the same subnet as the IND 360. So that's the same first three numbers. It ends in.8 for the 360, but mine needs to be unique, something that's not in use on that network. So I'll go ahead and select that right there, the 125, and then just do 255, 255, 255.0. And then I'll go ahead and leave everything else the same, and then we'll save that. So now if I come back to my web page, my connection was interrupted and we can then see we are connected. So that's how we connect to the IND360 web server for the first time. If we want to change the IP address, we can do that from this web server menu, but that'll be explained further on. Thank you.
So as we look at our new scale system here, I powered it up with nothing on the scale and we have a negative weight. If I put another weight on it, it's saying I've overloaded the scale, even though that's not actually the case. So all of this is telling me this scale is not properly adjusted. It needs some form of calibration. So to do that, I'm going to go to scale and then calibration. The first thing I want to take a look at is this geocode. So basically what this is a value that tells the device where I'm located in the world, how high above sea level I am, so that I can get a more accurate reading of how gravity is affecting my scale. It might seem minor, but if we want to increase the accuracy of our system, this is a way to do it. So I can simply look up the geo list because it's unlikely you'll know what your geocode is. So importantly, we have this table down here. So you can use various forms of mapping software for where you're located in the world to get your latitude. And then you want to find your height above sea level. So here I'm in Ohio in the United States. That is very low, very close to sea level. So I'm always in this first column. And I happen to know that my latitude gives me a geocode of 16. So I'm going to go ahead and set 16 as my value here, making sure I select save. And then I have a few different options for my calibration. So span adjustment is if we're using traditional test weights only. Step adjustment is going to be if we have test weights, and then we are going to use sort of a water substitution inside of a tank to sort of gradually build up to a very large adjustment value. The zero adjustment is if we're only adjusting the zero point by itself, and then cal free would be what we use if we're doing an adjustment without test weights at all. So that might be for initial testing before your test weights are on site. Or if you have a very, very large silo, where it's just not practical to have that amount of test weights. That's a good use case for CalFree as well. But the most accurate way to adjust your system is going to be with some version of test weights. So we'll go ahead and start with a span adjustment. We need to select what are our test weights, their weighing units going to be. So just because we're weighing in kgs, maybe somebody brings test weights in pounds or some other unit, we can select something else here. But in my case, I do have a kg test weight. Our linearity adjustment. So typically what most people are going to do is 2 points of linearity. So that's going to be the zero point as point #1. And then the second point, it's recommended to get as close to the full capacity, the full span of your scale as possible. So in this case, I have a 6 kg scale. I'm going to use a 5 kg test weight. Now, if we wanted to worry about linearity in that system, we wanted to have more test weights in the midpoints to really make sure we're getting accurate reading as possible. That's where we'd use these other values. But again, most cases, we're going to do two points of adjustment. So here, even though it's a 6 kg scale, as I said, I'm going to have a 5 kg test weight that I have here. So I bring up the calibration menu here. It's just telling me to make sure my test weights are ready so I can go ahead and start. It's telling me to empty my scale. So let's take a look at the scale here. And you can see I do have a motor that's already mounted to the scale. Now this motor is going to be permanently mounted. It's never going to be removed. It is a part of the scale. So I'm actually going to say that anything on that permanent structure attached to that scale is actually part of my zero point, right? If you have a large tank on top of weigh modules, that tank is going to be your zero point for your scale. So again, I'm going to say my scale is already empty and hit continue. And so now we've captured the zero point. It asked me to load 5 KG S of test weight, which I have right here. I'm loading again. You can see on that local display there it shows that it's overloaded because we've not done this adjustment yet. But as we proceed with this adjustment and this completes, we should see it comes up exactly at 5 KG S. So that worked perfectly.
All right, so when we're starting up with the ACT305, it might be good to know what are the minimum steps you need to do to accomplish and get set up with your scale. So what are the basic steps to get up and running? So I can see here I've got nothing on my scale, but I still have a weight of 5.14 kgs. I can see I'm not communicating to my PLC, so I definitely need to do some work. It's not just going to work directly out-of-the-box. So I can come down to this question mark here, and I can see it's highlighted the setup assistant. So this is going to walk me through the three basic steps for getting this ACT305 set up and communicating with my automation system. So the first thing here, I want to know a little bit about my scale. So what weighing units am I going to be using? In this case, I am going to be using kg, but the scale in front of me is actually only a 6 kg capacity scale. So I'm going to set it 6 kg capacity and we'll set it at increments of 1g. So that's OK for me. As we get into Step 2, this geocode is essentially asking for. what is my latitude, what is my elevation above sea level, these things that if we really want to be as precise as possible can affect the weight depending on where we are in the world. There is a separate tool inside this web server to look that up, but I happen to know where I am in Ohio is actually a geocode of 16. For my adjustment, we have three adjustment types available here, but the still most accurate adjustment value is going to be using test weights, and that's going to be what we do with the span adjustment. So I'm going to go ahead and select the span adjustment here. If I happen to have test weights that were different units than my weighing units, I could select something different, but I happen to have kg test weights here in front of me, so that's okay. The linearity adjustment. So typically what most people are going to do is they're going to do the two point adjustment. The first point is the zero point of the scale and the second one is going to be as close to the full span of the scale that we can get to. Now, if we want to get more accurate, we want to put some midpoints in between there. That's where we can use these other linearity adjustments with more points if you have the test weights to accommodate that. But again, for this video, we'll just go ahead with the two points of adjustment. And I am going to use a 5 kg test weight here today. So I'm going to go ahead and pull up my calibration screen. We can take a look at the scale in the room here. I'm going to start because I have the test weights ready and it says the first empty the scale and you can maybe see I have this little motor on top of the scale, but that's going to be permanently attached there. I'm going to say that's a permanent part of the scale structure, so I want that to be captured as part of my zero point. So I'm going to leave that on there and I'm going to say the scale is empty and continue. All right, so we've captured the zero point. Now it would like me to put my test weight. So this is a 5 kg test weight. We loaded that on there and we'll hit continue again. All right, and in the background there and on the local display, you can see we were successful with that adjustment. The third step, right, since this is an automation device, we want to make sure that we are talking to the PLC, the automation system. So the first thing I want to do is I want to make sure I'm selected Ethernet IP in this case. If I was using a Profinet PLC, I could use that instead. If I have a different ACT305, it might have an option for EtherCAT if I configured it that way. But here, Ethernet IP is fine for me. The data format is left at 2 block. The data OK mode, in 99% of automated applications, we're going to want this to be left at standard. So in that case, we're going to leave that there as well. The byte order, again, in the vast majority of cases, automatic will work just fine. If you have some issues with byte order, then you can mess around with the setting, but automatic is going to work for most cases. Scrolling down towards the bottom, we see the IP address, how we're going to communicate to the PLC. And then this, importantly, this toggle button is supervision, right? So if we have that on, That means if we are not cyclically communicating to a PLC, it is a high level alarm. If we do not want that to be a high level alarm, we can toggle that off. So for me, in my case, I've not configured the PLC just yet. Maybe we want to do some separate testing, but I don't always want to have this alarm there so I can see other issues that maybe come up without always knowing that I have an alarm. So I will go ahead and disable that and I will select done with these settings. And so our setup assistant is complete. I no longer have the red X for Ethernet IP. It's not a green check mark either, so I don't know if I have the communication or not, but that's OK. And we can see as I remove this test weight, we will return to our zero point. So it's just that easy using the setup assistant to get up and running with the basics of ACT 305.
So inside this web server of ACT305, we do have a few nice helpful features of what we might call integrated documentation. So that comes up in a few different forms. So as we go through, we might see these blue sort of information icons. We can hover over those and get tooltips, a little bit more information about what's going on there. So we can see with the approval, we get a little bit more detail. Again, with the filter, we can see what happens as we go from 1:00 to 10:00 with these settings. But what if we want as much detail as possible? We would always go to the user manual, right? But what if you were on the plant floor? Maybe you don't have internet access there. You're at a customer site. For whatever reason, you can't access the user manual online. You're not sure if you have the up-to-date user manual saved to your computer. What's nice with the ACT305 is we actually have the inside the web server a version of the user manual that is tied to the version of firmware currently installed on the unit. So if we come to this question mark, we can click the user manual. And what's nice there is since I was on the filter page, it guesses that I want to look at the filter settings. So it automatically brings me to the filter page. That being said, we can see the table of contents along the left side. So I can look to see what topics we might have here. I can see for example under PLC, industrial Ethernet, Modbus, TCP, analog output. If I had questions on PROFINET for example, I don't see PROFINET listed here in the table of contents. So what I can actually do is I can just search for PROFINET. and it'll pull it up, I can see, oh, that's underneath industrial Ethernet. You don't need to be an expert on where everything is within this manual. There's a nice, quick, and easy to use search function built in. Now, with that being said, that's not all we have in terms of integrated documentation. Again, if you're a PLC programmer, it might be good to know what sort of PLC commands are available for the device. So for that, under communication and PLC, We can click this button for SAI command, and that's similarly going to open up a page with the PLC commands that are available for this device. You can see I have this device set up for Ethernet IP, so that's why it's only showing me the Ethernet IP acyclic class instance and attribute values. What's also nice here is that if I decide that, hey, I don't care so much about the group or the subgroup, Maybe that's cluttering my screen a little bit too much. I can come in here and I can make sure that those disappear. It makes this a little bit easier to sort through with just the data that I want. Again, similarly, if I want to do something with the filter of the ACT305, I can simply search for filter and see wherever that comes up so I can see OK if I want to report or write the filter environment. This is the command I need to use, again making it as simple as possible to get up and running with this device and start working with it. Answer all those help questions you might have. Of course, if you get stuck, a Mettler Toledo does have technical support all over the world, and they're happy to help you out if you need something further than that.
All right, so here we are in Studio 5000. We are looking at the sample code project for ACT 305. We're going to get in this video in ACT 305 connected to a Rockwell Allen Bradley PLC. We are going to also incorporate elements of the sample code project, so I'm going to use a blank project. and import an element of the sample code project because that's probably more realistically what you're going to do. It's unlikely that you'll start with our sample code project as the basis of your automation system. It's likely you already have something developed and maybe you're adding the ACT305 to it. So we'll go ahead and show those steps, but I do want to briefly cover in this sample code, we do have several add-on instructions here. So we have our weight processing add-on instruction. That's going to give us the weight values, whether that's gross or net weight. It's going to allow us to have some commands so we can tare, do what we call a push button zero, which is sort of a brief modification of the zero point for drifting or maybe some temporary elements that have shifted the zero points. We can clear the tare. And we also get some basic status indication, such as whether the weight is in motion, if we have a high level alarm, things like that. As we look at the next add-on instruction, we have something to monitor the heartbeat bit, making sure the communications are always active between the 305 and the PLC. The next add-on instructions allow us to read the capacity and increment values from the device. Then we can write the capacity and increment values to the ACT305. This add-on instruction allows us to do a formal zero adjustment, right? I talked about that top add-on instruction doing what we call a push button zero, which is slight modifications. It's typically if the zero adjustment is too strong, it will fail with a push button zero. If we need to make a larger adjustment or maybe we're setting the zero point for the first time with our scale, that's where we want to do this zero adjustment. Going further down, we can do a full span adjustment. So this is where we have test weights. This is a process that the sample code will sort of walk you through. We do have a corresponding engineering note to give even further details about how this should work. But we can initiate that through the PLC. And then finally here our Cal free functionality. So this is an electronic sensitivity adjustment. So this is what we do if we don't have access to test weights, maybe for initial testing, or maybe we have a very large silo where it's just not reasonable to get the amount of test weights you would need to cover the full span of such a large silo on your your weigh modules there. So that is the sample code. So what I would do here is I would look at what elements of this sample code do I want to bring into my new project. So here in this video we will import or we will export one rung. So I right click on the rung and I will export it. I've already done so, so I will not replicate that here, but you would simply export that and we'll import it in our new project. So if I jump over to my blank, new Studio 5000 project, you can see I have nothing in my main routine, and the only device I have over here is the PLC itself. All right, so let's go ahead and add an ACT305 to this new project. So we want to search for ACT305, find that there. We want to give it a name. You can name it whatever meaningful name you have for your project. I'm just going to call it ACT305. The default IP address for the PLC communication is 192.168.0.2. And then I want to change a couple key things here. So we're going to use the two block format. And as of right now, I'm just going to disable the keying to take care of any strange matching issues there. So we'll go ahead and select yes, and then we will close out of this. It's added to the project. One thing I do want to double check though is in the web server of the ACT305, I want to go to communication and PLC. So I want to make sure that my settings in the device itself match what I just put in that PLC project, right? So I want to make sure I've selected Ethernet IP. I'm not trying to use Profinet here. I want to confirm I am using that two block format, which is the only option here. And the IP address does match. The other thing I will say is this supervision bit can be key and can be critical. Right, so what this does is it's you confirming whether it is a high level alarm for the ACT 305 to not be talking cyclically to a PLC. So right now I was doing some previous setups. I didn't want a flashing red alarm at all times, so I turned that off. Now for this purpose, I will turn that on and select save. Just one other key thing to note here for the PLC commands that our sample code uses. You can find all of that and many, many more if you click on this SAI command page. It will bring up integrated documentation, which we do have a separate video explaining further. But now that I've turned the supervision on, you can see I have a red X for Ethernet IP, telling me that I do have a problem. If you look in the bottom corner of the screen, you can see the panel display of the ACT305. In the bottom left corner of that panel display, you can see we have that same X icon indicating we have a high level alarm. So if everything goes successful here, we should hopefully see that disappear and turn into a check mark showing that everything is okay. But with that, let's go back to my new Studio 5000 project. So I've added the ACT305. The settings all match. And so now I want to import A rung. Sorry, not add the rung. I want to actually import. So here I just need to navigate to where I saved that previous rung. That's in my Studio 5000 folder. I can see this ACT 305 rung. So I'm just going to say OK to everything. We can delete this previous rung that I added by mistake. And you can see, once I've added that rung, no additional configuration is needed because I used that ACT305 name. So what I'm actually going to do is I'm going to set up and connect to and download this PLC project. All right, so I go to download. All right, so now you can see we are connected to the ACT305. We can actually take a look at the scale that is in the room here. You can see we have a 1 kg test weight. So if we look at the real time weight and the stable weight, you can see those change. And as the weight is being added and taken away from the scale, You can also see the motion bit along the right side is changing until the weight stabilizes. So notice while that motion bit is active, the stable weight does not actually change, but the real-time weight does. The stable weight is only changing once the weight stabilizes, as you would imagine. Similarly, if I want to tare my scale, I can simply send a 1 to either the tare immediate or tare stable. A tare immediate will always take effect. Tare stable will only tare if the weight value is stable and not in motion. So it looks at that motion bit as well. So there we can see on our local panel display at the bottom corner, it's gone to 0. It says we're in net mode. My sample code, my AOI says we're in net mode, but my weight still says 1.0. So this can be a common issue, which is basically with this weight command here, we have that set to 0, which if we look at the comments, is that 0 reports the gross weight, 3 reports the net weight. So let's go ahead and clear the tare, because this weight command is what command are we going to return to after we execute this tare, for example. So now if I tare and we'll do the tare immediate again, we can see the weight goes to zero and it matches my display. So we just want to be sure we are specific about what commands we are sending in those cases. But again, I can send a clear tare and clear that out. The one other thing I will note here is this preset tare. Right, so this would be used if we have a known container weight. Maybe it's already filled with a material, so we want to tare with a known value. So for this example, let's say we know that we have a vessel that's on the scale that's filled with some material. We don't know the weight of the material inside the vessel, but we know the vessel weighs, let's say 1.5 kg. So let's swap this 1 kg weight out For a different weight, we can see that's five. And so now what I want to do here is I want to set the pre-tare value. So let's say that's 1.5 kgs. And then I want to execute the preset tare, right? So now we see it has subtracted 1.5 kgs just as we requested from that preset tare. We've gone into net mode and then I can Clear this and everything goes back to normal. So it's just that easy to get the ACT 305 set up with the with Studio 5000 to connect to your Rockwell Allen Bradley PLCs using our sample code and our device drivers. Thank you.
All right, so if we look at our calibration methods, we can come to the Cal free. So this is how we can do an electronic sensitivity adjustment. This is great if we don't have test test weights yet. So here we need to put the total cell capacity. So if we have multiple weigh modules underneath the legs of a tank, for example, we want to add up. All of the rated capacities for each of the load cells and add that added value here. Then we want to tell it what units this value is in. So in this case it's kg and then each one of your load cells you can search online. We have this website here, this Mt calibration certificates page. You can input the serial number for each one of your load cells and it will show you the actual rated. Cell output in millivolts per Volt for your load cell. So on your label it might say 2 millivolts per Volt, but actually during testing of the device it might have been 1.95 or something along those lines. It's not exact. So what you want to do is you want to take those for each one of your load cells and you want to average those to a single value and you put that average value in here. And now for me, I'm using a bench scale that uses a single point load cell. So we can take a look at the bench scale here in the room. And one thing to note is that if I peel this up and I actually look at the label on my bench scale, it tells me it is a 6 kg capacity scale. But that's not the load cell itself. For actually the load cell, I need to look underneath and I can find that single point load cell which still has a label on it. And that's going to tell me that this is actually a 10 kg load cell. That's to account for the platter and some of the other things that are put on top of it. But for CalFree, we want the load cell rated cell output. So there I looked it up. Even though it says 6 kg, the load cell is rated A 10 kg load cell. And my rated cell output is 2 millivolts per volt. So I'm going to go ahead and calibrate based on that. So we can see it is successful. And if I come back here to the home page, I'm going to put a one kg test weight on there. And we see it is not perfectly at 1 kg like we would see if we had used test weights to begin with. But this is going to get us in the ballpark. So again, we can do some rough testing, maybe until those test weights are there. Or if we're on a silo, which is not feasible to add that level of test weights to it, cal free is a good way to get started.
All right, so here we are in the sample code project for EtherCAT for the ACT-305. You can see we have some basic blocks such as checking the heartbeat, changing adjustment settings, performing a zero adjustment, performing a span adjustment if we have test weights available to us, or a cal-free electronic sensitivity adjustment if we do not have test weights. So this is the sample code project, but it's unlikely you're going to use this as the starting point for your automation project. So what we're going to do here is we're going to show you how to export this and import it into a new project. So we export this XML, and then we come over to our new project here. So in this new project, I'm going to go ahead and I'm going to add an ACT305. So I'm going to find Mettler Toledo here, and I'm going to expand these menus and find the ACT305 and add that to my project. Not changing any of the settings so far. We'll just continue along, and we're actually going to then take a look at the web interface for the ACT305 just to confirm some settings on that side. So we'll go to Communication and then PLC. confirming the data type, the block format, and then I'm going to turn the supervision on. So this will give me an alarm if I'm not communicating to an EtherCAT PLC. This SAI command button you see here will pop up with the integrated manual for the PLC commands. And in that top right corner, you see we have the red X showing we are not currently communicating to an EtherCAT PLC. So that supervision bit is doing its work. If we return to our new project, we can come in here and we can then import that XML that we exported previously. We'll select all of the checkboxes and if there's any conflicts, just replacing with the existing object. So we can save this. and we can then try to open it up, see that we have those same blocks earlier. This weight processing block is going to be most of what we work with here at the top for this video. And then we can try to compile this and see if it runs. So I can see I need at least one variable linked to a task variable, so that's okay. I'm going to then go to my global variable list, And I can see what variable it's expecting to be linked. So if I go back to the AC T305 data addresses, we can then create the link with the required data points. This will link the real world variables with our script. All right. So we can try to compile this again now that we've completed that. And you'll actually see that we have some errors here. So what is going on? I can actually come up here and go into config mode. Once I'm in config mode, then I can do a scan of my system. So if I right click and go scan, I can see it's expecting a different device name here. So I can just change that to what it's expecting, select OK. And now I can then see, okay, I've got some live data from my scale, which does have a weight of 1 kg. So now we're restarting in run mode, and we can take a look at what we imported previously as the sample code and see how that's working. So if we go online here, We can see we have quite a bit of information. We have a heartbeat bit that is toggling on and off, true and false every second, letting us know we have active communication. We have alarm bits. We have something telling us whether our weight value is in motion or whether it's stable. So motion bit is true or false. And we have a net mode bit that's going to tell us if we have a tear that is currently taken or not. Up at the top, you see we have the reported weight and the stable weight. You can see the reported weight is always updating live. The stable weight is only updating if the motion bit is false. So that's the distinction there. But as we turn the simulator, we can get that back to 1 kg weight value. We see that that matches for both stable weight and the reported weight. So I can force this tear stable command high, and we can see our stable weight and our net weight, our reported weight has dropped to zero. Our net mode bit is high, meaning we have taken a tear successfully. And then if I were to force the clear tear command, we can see our weight jumps back up to the 1 kg it was before the tear. Our net mode is zero. That is because our weight command is 3, which is the command for reporting the net weight. But sometimes what you'll see is someone uses a command such as 1, like you see here, and then they take a tare, but you notice the weight values remain at 1, even though the net mode bit is true. That is because we're telling the ACT-305 to continue reporting the gross weight value. So that'll be the case until we switch that weight command to 3. But it's just that easy to import the sample code for TwinCAT software environment and start getting up and running with the ACT305.
Here we are in the web interface of the ACT305. We can go to the PLC settings, making sure we have selected PROFINET, and then we're going to turn on our supervision bit. This is basically going to tell us if it's an alarm, if we're not communicating to the PLC. I need to give it a device name, of course. So here I will select ACT305 as my name, and I'll select save. This does require a restart of the terminal. While it's doing that, we can see in the top right corner of the web server, we have a red X next to Profinet, just that supervision at work telling us we do not have PLC communication active. So here in TIA Portal, I'm just creating a new project. I'm just going to name it something simple like My Project. Now once that's created, I'll go into devices and networks, and I will find the controller that I am using, which is an S7 1500, making sure, of course, I select the correct CPU and the correct version number for what I have in front of me here. So with that controller added, now it's important to note I pull in a reference project. The reference project I'm using is the ACT305 sample code, so I can pull whatever I need from that sample project. So what I'm going to do is I'm going to pull the weight processing block. I'm also going to copy the entire ACT function block. So here I see I have quite a lot of things I can select from. You can pull in whatever works for you and your project. I'm going to select the weight processing function block along with its corresponding database. So then I go into my own new projects, program blocks, and then I can simply paste in what I copied from the reference project. So I am going to need a couple more things to make this new project work. So I will navigate to those in my reference project. The first thing will be the PLC data types. So I want to select these three data types and then add them to my new project. Then I want to go into my PLC tags, opening up these tags here. I'm going to select the first few tags from command value down to command. I'm going to copy those, and then I'm going to add a new PLC tag table, just calling it something simple as ACT305, and then I'm going to paste those tags in there. All right, so then if I open up this ACT application that I brought in, I can see that weight processing block that I copied the function block for is looking good. But I do have errors and alerts on the remaining networks, which makes sense since I did not copy those function blocks into this new project. So I will go ahead and take care of those and remove them. And so now we just have the weight processing block. So that should take care of those issues. So let's compile just to be sure. And it looks like everything is okay so far. So now if I go into my devices, I can find the ACT305, and I can add that into my project here. Of course, making sure to make a connection to the controller via PROFINET in the project here. So then I also want to make sure that the IP address matches whatever the setting is for my ACT305 that I'm using. And then take a note of these IO addresses here, because that's we want to change our PLC tag tables. We want to change the addresses here to match. So just matching command value here to command value in the I/O table we saw previously and continuing that throughout this list. So here we can now download this to our controller. So we go ahead and tell it to load the configuration and then to finish here. So on the right side of the screen, we can see the web interface of the ACT305 showing the current weight is 0.00 kilograms. If I go into my project here, I want to open up the program blocks, and I want to take a look at that ACT application. Let's go ahead and go online to see what information we can get out of this device. I can see everything is green, but I'm not getting any data out of this wheat processing block. So this is, of course, as a programmer, when the panic starts to set in, when you realize you've made one of the simplest mistakes possible, which is just not calling this application from our main routine. So let's go ahead and open up the main routine in that reference project, copy that call there, and paste that into our new project. All right, with that simple fix, we can then download, and we can see everything is looking okay. If we go online, we get weight values. So we have the real-time weight and the stable weight there in our PLC, both showing the same weight we see in the web interface. Now as it changes, you can see the real-time weight is always going to update, while the stable weight is going to wait for the weight to stabilize before updating. All right, so now we can see our weight value has changed to 3.5. We're going to force a tear command. We can see after that, the weight drops to zero. Our net mode is true, so the tear was successful. We can add a little bit of weight here, so it's going to increase to 0.22. Remembering we started with 3.5. So now we can send a clear tare command. And we can scroll back up to see we are at 3.72 as we would expect after returning to gross weight. So it's just that easy to get up and running with an ACT-305 connected to a PROFINET PLC.
Alright, let's take a look at the zero menu of the ACT 305. So for there we're going to go to scale and then zero. Just a note, what we're talking about today is more mild adjustments to the zero point after you've already calibrated your scale. If you're looking for more information on how to do the formal zero adjustment when you're initially calibrating, that's going to be covered under our calibration video, which is separate from this one. But as we look at the zero menu, we'll start on this right side here under the ranges. So the first thing we want to know is what Zero point do we want to use when we first power up the ACT305? So here what the vast majority of users are going to want is to use the calibrated zero, right? So that's when we do that formal adjustment I talked about in the separate video. We want to revert to that after we power back up. Maybe if you have a scenario where you lose power quite frequently, or for whatever reason if you do lose power, you want to come back up and start back at the exact same zero point you had before the power loss, that's maybe you want to use Last Zero. In very rare cases, if you have a very tightly controlled process, you maybe say, wherever we power up at, whatever is on the scale at that point, that's my new zero point. But again, that's very uncommon. In almost every case, I'm going to see that people are using the use calibrated zero. So we'll stick with that. But that being said, it is quite common to see slight accumulation of material on your scale. Maybe it falls out of a drum or a bag or something like that onto your scale. Maybe you are outdoors and you have a snow or other debris that accumulates on your scale. So you want to give your operator some freedom to make some small adjustments to that zero point as needed. So for that we have what's called the push button zero. So your ACT305 maybe has a zero button on the front. That when you push that button is what we would refer to as the push button zero. But there is also a push button zero command via the PLC. And if we go to our home page here, this zero button is also a push button zero. But you can imagine, as an operator, mistakes can happen, especially when the zero button is right next to the tare button, which maybe they are meant to use more often. So we typically want to have guardrails to make sure the operator doesn't accidentally zero when we have 50 kgs of material on our scale. So for that we have these zero, push button zero ranges here. By default, it's plus or minus 2% of the capacity of the scale. So our scale right now and for this video is set up at 100 kg capacity. So just to make the math easy on everyone, our acceptable range will be plus or minus 2 kgs. So right here, as you can guess, if I push the push button zero, Nothing happens. If I go to my maintenance log, I can see we had a zero out of range error. So that's what happened there. If I reduce the weight on my scale, so we're at 0.6 kg, I can zero. Let me see if I can chain some of these together. So 0.5, that's no problem at all. But now, If we try to do that a third time, again in the same direction, this time we'll make it a little bit bigger, 1.4, that's still within my 2 kg limit we talked about, but nothing happens. So I can check my log and I can see it says 0 out of range again. And that is because that 2% plus or minus is looking at the calibrated 0 point, not the current 0 point after these push button zeros. This can be another nice guardrail. If we have a continual drift in the weight in only one direction, so always positive or always negative, we can flag that to say, hey. Let's not just, you know, Band-Aid over this problem with constantly doing a push button zero. If we have that much drift over time, maybe we want to have someone come take a look at this scale. So again, we had .5 kg and .6 kg, so we're at a total of 1.1 KGS in the positive direction. So if I actually go. Beyond, so I'm outside of the two kg limit in the negative direction, it'll still let me zero because we had already done a push button zero in the positive direction. So again, these guardrails are still working, but just note it's not always as simple as just looking at the display. It's really about knowing where that stored calibrated zero point was. But if we come back here, taking a look at our other examples, the auto zero, this is really to deal with some drifting issues. Maybe if you have small drifts over time, by default it is off, but we can set it to gross or gross and net. Gross and net would be used, obviously, if you've taken a tear and you want it to revert back to that zero point. By default, it's set to half of a division, half of our increment size. So here our increment is 0.1 kg. So that's only going to automatically set that zero point if we are within half of that value. So really small changes here would be typical. To show you the effect though, I will exaggerate that and let it go to the max value, which is 9.9 divisions. So we've got a little bit wider of a range here. So you can see we're exactly at 0, but if I Move this a little bit away, we'll see the ACT 305. As long as there's no motion on the scale, we don't go back outside of that 9.9 increment value, it will slowly drift back to that center of zero point and stay there. All right. And you can see we had to speed that portion up because it is a slow, gradual process. It's not going to just snap automatically to a new zero point. It's really just looking to automatically do that if we are drifted or a little bit off that zero point. So again, I would say leaving it at a much smaller value, like the default of 0.5, is going to be more reasonable here. Finally, our under zero blanking. This is really typically more commonly used in manual applications, but basically what it is that sometimes in manual applications there can be a requirement that if you go under zero by a certain number of divisions, we need to blank out the display so the operator cannot see what's going on. In automated applications, that's not typically needed. So by default, this is set to the maximum value of 99 divisions, which will actually make the under zero blanking only occur at minus 50% of the capacity of the scale. So with 100 kg capacity, it'll only blank the under zero when we're at negative 50 kgs and below. So to make this a little bit easier to see, though, I can Actually set this to 9 divisions. You can see we're at zero, and if I start to go in the negative direction, we can see we are below 0, and once we go below 9.9 divisions. That's where we see the display blank out. Again, not too typical to see this. Again, I would say in most cases, you're going to leave that at 99. That to be said, just to be clear, even with this set to 99, even with it set to something lower, the automation system, the PLC commands, will still see the actual weight value no matter how far below 0 we go until we reach a saturation point or something like that. So that is how we use the zero menu in the ACT 305.
So one topic that can sometimes be overlooked is setting the accurate time and date stamps inside of the ACT305. So you can see here on this device with this red X, we do have some alarms currently active in the system. We can see those alarms here and those do receive the time and date stamp of when those occurred. So with automated systems and especially complex automated systems, With more and more devices capable of reporting their own alarms, you can sometimes find cascading alarms where an alarm on one device triggers an alarm on another device, and it cascades further down the chain. So it can be critical to have accurate date and timestamps on all your devices to make sure you can trace back where those alarms originated from and not waste so much time troubleshooting each individual device. So to do that in the ACT 305, we come to terminal and then region and then time and date. And you can see here we have three methods for setting the time and date. On the left side here, we have our simplest method, which is just manually entering in this data. So we can use a calendar feature to set the current date. We can set the time, and we can change the date format. So I am located in the US, where we use month, date, year. But the default, since it's used in most of the rest of the world, is the date, month, year format. But that's easy enough to change. If we're just manually setting this all the time, it's not really necessary Necessary to change the time zone for where you are. But if we use any of these other features and we just leave it at this default, that could cause us problems. We'll show that here. So if we look at setting our SNTP client, we can enable this and we can save that. You can see now we've jumped from 11 o'clock in the morning into the afternoon, and that is because of this time zone here. We did not properly set that. So for myself, where I'm located, I am four hours off. So you can see once I set that, we are back to being at 11 in the morning. That being said, this IP address of course is the timekeeping server I'm using on my local network. That would not be the same for your network. You would of course need to reach out to your local IT to find out what NTP server you could use in your local system. If you do ever want to trigger a manual update, you can do that there, but it will periodically update based on that NTP server. So if I don't want to use that NTP server, I can disable that there. And since I am connected with my PC using the web server to the ACT305, I can tell it instead to just pull the local time from my PC instead. And so then you can trigger a manual update here. Of course, that'll only be able to update if you keep your PC connected, if you keep this connection active. If you need something that's sort of a set it and forget it, that'll constantly maintain itself, especially if you have, say, daylight savings time or any sort of time changes throughout the year, it might be a good idea to use this SNTP function. Or again, you could just manually set it for each device. But that's how we quickly and easily change the time and date settings for ACT305. It seems maybe a little unimportant, but once you have those errors and alarms that start popping up, you're really going to want to have done this from the beginning. Thank you.
Let's take a look at the tare menu in the ACT 305. So to navigate there, we're going to go to Scale and then Tare. And you can see we have three different tare functionalities, Push Button Tare, Preset Tare, and Power Up Tare. The most common one most people are probably familiar with is what we refer to as the push button tare. So your ACT305 might have a tare button on the front that if you push that, it will put you into the net weighing mode so we can measure just the net contents of what we're adding to or subtracting from a vessel. But it's not only on that front physical button. Inside the web server, this is also going to be our push button tare here. So if say we start with a 10 kg vessel on the scale, we can tare there. And as we add or remove, you can see it indicates that we are in net weighing mode. So this is the net weight instead of gross weight. And then we had our tare taken at 10 kgs. So then, once we're done with that, we can clear the tare and go back into gross weighing mode there very easily. The second option, the preset tare, is when we have containers or vessels of a known weight. Maybe they're pre-filled, whatever the case may be. We don't want to measure that vessel when it's empty, or maybe we can't. But since it's a known weight, we can automatically set a preset tare of 5 kg if that's our vessel weight, and we can tare. So again, you can see we go into net mode, and instead of 5 kg's T for tare, it's 5 kg's PT for preset tare, again, just so we can easily differentiate how we arrived at this value, but it's going to function very similarly. The final option if we return to our tare menu is the power up tare. By default, this is disabled. If you want to use that, is as simple as clicking that radio button and clicking save there. This is not so that we take a tare when we power up the ACT305. It is actually whether or not we want to retain a tare that was taken before a power cycle. So if you maybe occasionally lose power, that maybe would cause you big headaches if you're in the middle of filling a vessel of some kind, that's where you maybe want to enable this power up tear to retain that. Now obviously you would want to control your process very well through that power loss. You wouldn't want to have new items being added to or subtracted from. your scale without knowing it. Maybe you swapped out your vessel that you were filling, whatever the case may be. Those might be situations where, again, you want to leave that disabled. And similarly, if you want to not allow your operators to set a preset tare and sort of custom program in that tare value, or you don't even want them to be able to push that tare button at all, maybe they accidentally push that button when not needed on the front display, you can simply disable those as well. But you can see the tare menu is very straightforward and very easy to use in the ACT305.
Let's take a look at the log capabilities of ACT305. So to do this, we're going to go to maintenance and then logs. And you can see we have four main logs here. We have the notification log, change log, maintenance log, and the calibration log. So the notification log is that's what's going to let us know historically what alarms, alerts, and errors there have been on the device. That'll give us a nice date and time stamp and alarm ID. It'll categorize how severe, right? This red level is our highest severity alarm. It'll tell you a message of what the alarm or the alert is and a recommended action to remedy that. But just note that this is historical. This does not mean these are all currently active on our device. To see the active alarms and alerts, we see this flashing red light here in the top left corner. We can click on that and we can see only one of these is actually active right now, that control network failure. So if I actually want to come in and remove that, so I can tell the ACT305 not to monitor for that particular alarm, now we can see that red light has gone away. We can come to these notifications and we can see there's no active notifications in our system. If we return to our notification log though, we can still see that historical data captured there. And like with most of our logs, we do have the capability to export. That will generate this table we see here in the web server as a CSV file with those same columns, easier to share with colleagues or a technician if you needed to have some additional help troubleshooting your device. If we take a look at the change log, we can see the values that I have changed over time. So we can see what I changed those values to. Here you can see me turning off that supervision bit that I just did a moment ago. You can see previously I changed the capacity and increment values. So this is really going to be great to capture anytime we change a specific parameter. on the ACT305. And that'll be captured here. So if you start to have issues, you can maybe look and see if someone made a change around that time or what the previous changes were before those issues started to pop up. And maybe your system started to act differently than it had before. If we move on to the maintenance log, so this is going to capture things that are a little bit more beyond just changing a single value. You can see some examples here. So I did a span calibration, I exported a change log, and those were captured here. So those things that aren't as simple to capture in a change log, the maintenance log will capture those. And again, those can be exported as well. Finally, the calibration log. So this will capture anytime I perform a calibration of any kind. It'll date and timestamp it. It'll show me the raw counts for the zero point. It'll show me what calibration weight I was using, and it'll show me the counts at that calibration point. So that's what we use there for the calibration log. You might notice that we do have a delete all button here. Be very careful around this button. Obviously this will delete all of these records. It will warn you before it does so, but it's only two clicks to then delete all of this. If you were concerned that maybe an operator might do that by mistake, I would highly recommend using the password protection feature of the web server, which will block this delete all feature as well. There are good use cases for it. So for example, if you're first setting up your ACT305, you might have some alarms at first when you're setting up the device that aren't really meaningful to you historically. So once you get your device set up, you might want to hit delete all. So that way you only capture the really meaningful alarms going forward. If you have a technician comes in to service your scale, they maybe would want to only see the next time they're there what alarms have come up since the last time. when they were at your facility. So when they get ready to leave, if everything's looking good, they might delete everything beforehand so they can start fresh. But again, I would be very careful on that because this error and alarm data, these change information, maintenance information is so key to maintaining the health of your device and your system. You don't want to lose that insight. But that's how you work with these logs on the ACT305.
Let's take a look at backing up and restoring the settings of the ACT 305. So once we get the device set up just how we want it, we set our capacity and our increment, we calibrate the scale, we do everything just right. It's a good idea to take a backup in case anything were to fail in the future. If somebody were to change a setting and you can't get the performance back the way you had it just right for whatever reason, that's always good to have a good known backup that you can revert to in any case. Also, it's very common to have multiple ACT 305 performing a similar function. For each one of these scales on your line, so you can set up one manually by sort of making those selections in the web server, create a backup and then restore it to the additional ACT 305 S so you don't have to duplicate those manual efforts. But to do this, we're going to go to maintenance and then backup and restore. So before I do that, let's review some of the changes that I've made. So we can see the capacity is set to 100 pounds. The units by default were kgs. I've switched them to pounds and then the increment size is 0.01 pounds. We can also see I have an Ethernet IP configuration set up here. There is no red X because I told the ACT305 I don't have my PLC connected yet, so don't monitor that for an alarm. Otherwise we would see a large red X there, which is what you'll see in a default situation with the ACT305. But if we go back to our backup and restore, I say, all right, this device is exactly how I want it. So I'm going to generate a backup file here. So this backup two is created and now I can store that wherever I want to on my computer. It just generates it in my backup folder. I can rename it to something meaningful, ACT 305 backup and whatever the case may be for your facility. But then what I'm going to do here is I'm going to master reset the unit. It's common to do a master reset after a firmware upgrade and things like that. So you can perform a master reset after that upgrade and then restore this backup file. So again, you don't have to manually re-enter all of those values. But we'll go ahead and do that here. We'll see the unit come back up with some different information and we'll test the restore functionality. All right, you can see we're back up and running after that master reset. You can see our capacity is 60 kg instead of 100 pounds. We're at 0.02 kg increment size, and we've got that red X we talked about next to Ethernet IP. So again, after that master reset, maybe you wonder how to get your system back to where it needs to be. But again, we just return to the backup and reset, and we're going to go to the restore. Here for the restore, we have a couple of choices. So there are two main common areas where maybe we don't want to pull the information in from that backup file. The first one being the calibration data. If we have a very old calibration data, we've had several calibrations since, maybe we don't want to pull that old calibration forward. So there we could select to not include that. I'm going to go ahead and include that here for this video. And then the Ethernet configuration. So that case where maybe we have a single ACT305 that we set up, and then we duplicate all of the settings for each one of the other ACT305s on the same line. That would be a problem though if you've already given each of those ACT305s a unique IP address to communicate. So then we would revert them all back to a single IP address, which would obviously cause configuration errors. So in this case, again, I'm going to go ahead and pull that through as well. So I want to get absolutely everything pulled in from that backup file. I want to be functioning exactly how I was when I created that. So let's go ahead and click restore. Here I just navigate to my downloads folder, select the proper backup file, and it will say that it was restored successfully. That's where I can come through. And I can see here what's happening. So we can see we've got that 100 pounds. We can see the.01 pounds. And we can see we have no red X next to our Ethernet IP. So that restoration was successful using that backup file that we just generated. So it's that easy to take backups and safeguard our device settings in case anything were to go wrong in the future.
Let's take a look at the access and security settings for the ACT305. So to do that, we're going to go to Terminal and then Access and Security. The first portion of this, you can see by default the web server is enabled. Obviously, that's what we are connected to right now. If for whatever reason you want to disable that web server, you would simply click this off. We'll leave it on for purposes of this video. But once you disable that, you either need to have local access to the menu of the ACT 305 through a display and keypad, or you would need to master reset the device back to factory defaults where the web server would be enabled again. Again, we do also have the capability to send a handful of simple TCP IP commands to the ACT305. If you do want to disable that, you would simply click that off right there. And then by default, Modbus TCP is disabled. If you would like to enable that, you can do so through this menu. But for the main portion of this video, we're going to talk about the system security. So by default, access control is turned off. So there are no passwords, no different login levels. You have the ability to read and write the settings of the ACT305. If you would like to restrict that, you can set that here. It will require an admin password. So I have one already saved, but I can let you in on a little secret. That is simply 123456 for myself in this video. So once we have that, Required. You can see now our menu is much more limited here on the left side. So we are not logged in right now. We are in the operator mode. And the operator, what they get access to. Is they get access to the weight value so we can see live changes to the weight along with the tare, clear tare and zero buttons that you would also typically find on the front of a device. But they do not get the chance to look at much other data other than firmware versions and things like that. So if we want to see a little bit more, we can log in to that admin mode. And we have everything available just as we did before we enabled the password requirements. But we have a new option down here on the left side called User. So if we go to User, we see we have the admin. Here's where we can log out. Here's where we can change our password. If we go back to our terminal settings, there is access and security, but we can come down here to User Management. Here you can see we have three different user levels. And if I want to change this so the operator, I cannot require a password. By default, the operator is just what you see if you do not enter a password. If everything is logged out, you get that view that we saw before. For supervisor, We can either disable the password, so you just need to select it as a different level, or we can add a password and I can just program in whatever makes sense for me as something different from the admin password. So I can save that. And now what I'll do is I will log out of my admin. See, we're back to that operator mode. And I will select the supervisor and I will enter that password here. And so now you can see we have again a lot of those same settings. But if I come to any of these settings, I cannot change them here because the supervisor can view the settings. It can get maintenance data, maintenance logs, things like that to maybe help with some troubleshooting, make sure everything is on track with the device. But it's not going to be able to write to make any of those changes. For that, you would need to be in the admin mode. So again, we can simply log out there. We can come to our admin. We can log in. And that's where if I go to those same menus, We can see that I can easily change and swap any of these settings as desired. Now again, if I want to then say that I no longer want to have this sort of access control, it's too annoying to have to constantly enter and re-enter this password, that's OK. We can disable it here. We can save that. Just know that will leave your system a little bit less protected. But the other thing I will say is that if you do ever lose access to your password, there are no backdoor passwords or anything like that. You will have to master reset the device to be able to make changes again. So please, once you set that password, keep track of it and do not lose it. But that's how we set up our access and security settings on the ACT305.
All right, let's take a look at the step adjustment for the ACT-305. So this is also known as the substitution adjustment. This is an adjustment method we would use if we don't have enough test weights on hand to do a full calibration of, for example, a very large tank scale. So to do this, we're going to go to Scale and then Calibration. We want to select the step adjustment here. Our units for our test weight we do have on hand is kg, and it is a 1 kg test weight. Now I've set the capacity of my scale to 3 kgs for this demo, and we'll see what that looks like as we go through this step adjustment. We'll go ahead and say calibrate, and we can take a look at the scale and the display we have here in the room. And so you can see we have a pitcher that is empty sitting on the scale. That is the simulated to have an empty tank, which of course, if we have an empty tank permanently attached to our scale, that would be the zero point for our scale. So it's the ACT305 web server is telling me what test weight to prepare and how much water or other material to substitute to have available as well. Let's go ahead and select start. And the first step of this step adjustment is getting that zero point. So let's go ahead. Again, that empty pitcher is counted as part of our zero point. So we'll go ahead and leave that on the scale and hit Continue here. Now we want to make sure we're reading carefully to the directions on the screen. It's telling me to place the 1 kg test weight. So again, that's the only test weight I had on hand. I can't go up to the full 3 kg capacity. So I will go ahead and place that there and hit Continue. All right, now I need to remove that weight. So let's go ahead and remove that from the scale and hit Continue once again. Now we need to add water. to our scale. So we're trying to get in as close as possible to 1 kg of material here. It's okay if we're a little bit over or a little bit under, but we want to be in the ballpark. All right, let's go ahead and hit continue again. And once again, we are adding that known test weight that we added previously, now with a little bit of water from the previous step. Once again, removing that test weight. And then once again, adding more water to get up to around 2 kgs of material. All right, we'll see if that's close enough here. And now it's asking me to add the known test weight once again. And we will continue. All right, so our calibration was successful. But just to confirm that, since it's easy enough for us to remove the water from the scale, obviously, it's maybe not the same case if you had a large tank of material. We just want to come back here to our home page. We want to make sure we are at the zero point when we start. And then I actually do have three kgs of test material we can use for testing here. So we see one kg, two kg, three kg. So our step adjustment was easy to do and was successful here with the ACT-305.
Keep weighing systems running reliably with commissioning, calibration, maintenance, and support services designed to maximize uptime and protect your investment.


Find more benefits in the datasheets:
_________________________________________________
Access manuals and more:
Documentation and support resources for ACT100 and ACT350 transmitters remain available for existing installations and transition planning.
ACT100 / ACT100xx Weight Transmitter Downloads
ACT350 / ACT350xx Weight Transmitter Downloads

That depends on your IT/OT integration needs, accuracy and speed performance expectations, andpreferred enclosure type. Generally speaking, the requirement of integration and control from low to high:ACT300, ACT305, IND360, IND590. The associated products page and documents provide detailedinformation so you can compare product specifications and application guidance to determine the best fitfor your system. You can also consult your Mettler Toledo contact for help.
The ACT305 and ACT300 transmitters support major OT protocols with certification such as PROFINET, EtherNet/IP,EtherCAT. Modbus TCP is supported as well (not certified).
The ACT305 and ACT300 transmitters are designed for simple commissioning and practical maintenance, with guidedsetup and helpful tools for everyday use.
Yes, they are still available for brown field installation or use within transition period. More information/materialscan be found in their download pages. You will find a link in an earlier session of this page.