DO Sensor InPro6860i/12/220/mA Ex

Digital Optical Dissolved Oxygen Sensor.The InPro6860i is an optical dissolved oxygen sensor which offers highly accurate oxygen measurements with enhanced stability, suitable for biopharma applications.

Immediate Sensor Availability

Calibration data are stored in the sensor. A pre-calibrated InPro6860i transfers that data to the transmitter to accelerate start-up.

For Digital & Analog Bioreactors

This optical DO sensor has digital (MODBUS, RS-485) and analog (mA) output signals for compatibility with benchtop bioreactors and transmitters.

Sterilizable and Autoclavable

The InPro6860i provides fast, precise oxygen measurement, even after repeated autoclaving and sterilization cycles up to 140° C.

Material No.: 30129735

Call for Quote
Specifications - DO Sensor InPro6860i/12/220/mA Ex
Measurement Parameter
Oxygen
Measurement Technology
Optical fluorescence quenching
Accuracy
± (1 % of the reading + 8 ppb)
Response Time
T98 = < 90 s
Primary Media/Application
Pharmaceutical/Life Science Production
ISM (Digital) or Analog
ISM (Digital)
Anti-Bubble Design
No
Wetted Metallic Material
316L stainless steel
Surface Roughnes of Wetted Material
N5/Ra16 (Ra=0.4μm/16μin)
Sensor Diameter
12 mm
O-Ring Material
EPDM
Power
25 V DC
0.1 A
Process Connection
Pg 13.5
Sensor Length
220 mm
Wetted membrane material
PTFE
Connector Design
Straight
Model Family
InPro 6860i
Autoclavable/Sterilizable
Yes
CIP resistant
Yes
Measuring Temp. Range
41 °F – 140 °F (5 °C – 60 °C)
Mechanical Temp. Range
-4 °F – 284 °F (-20 °C – 140 °C)
Operating Pressure (Bar)
0.2–6 Bar
Operating Pressure (PSI)
0–87 PSI
Design Pressure
87 psi (6 bar)
Analog Integration
4/20 mA HART active output
Digital Integration
RS485 - ISM® and MODBUS RTU
Cable Connector
VP6 / VP8 (analog / digital)
Hygienic/Biocompatibility Approvals
FDA/USP Class 7
Hazardous Area Approvals
ATEX/IECEx: II 1/2G Ex ia/ib HC T6 Ga/Gb II1/2D Ex ia/ib nie T83 °C Da/Db
Certificates & Approvals
Quality certificate, Material certificate 3.1, Surface finish certificate, ATEX/IECEx certificate, FDA/USP Class IV
Measurement Range
0...saturation
Sterilizable/Autoclavable
Yes
Measured Pressure Resistance
0 psi – 87 psi (0 bar – 6 bar)

Hygienic and Durable Design

Avoiding biofouling and ensure a stable signal with the PTFE coating and hygienically polished surface of the OptoCap™ oxygen-sensing element. The sensor has the durability to withstand multiple autoclaving and standard CIP / SIP cycles.

Uncompromised Reliability

This optical DO sensor offers the benefits and predictive diagnostics of Intelligent Sensor Management. Achieve faster start up with Plug and Measure technology. Increased system availability is provided by maintaining a stock of pre-calibrated sensors.

Exceptional Performance

The 120mm InPro6860i reduces both handling time and running costs due to lower calibration and maintenance needs. This performance is achieved by an electrolyte-free, one-piece replacement part that is monitored by predictive diagnostics.

ISM Monitors the Measuring System

This ISM DO Sensor continuously monitors itself to ensure it is working properly and the Dynamic Lifetime Indicator lets you know, in days when the OptoCap sensing element needs replaced. This helps to ensure safe, error-free oxygen monitoring.

Documentation

Datasheets

Datasheet: Intelligent Optical Oxygen Sensor Easy Handling – Exceptional Performance
InPro 6860i is fully equipped with Intelligent Sensor Management (ISM) technology to simplify sensor handling and reduce maintenance. With Plug and Me...

Manuals

Operating Instructions: Optical O₂ Simulator
METTLER TOLEDO optical O2 sensors are intended solely for inline measurement of the oxygen partial pressure, as described in this instruction manual.

White Papers

Corrosion reduction
This white paper provides educational content and shares practical expertise on corrosion and corrosion reduction in the chemical industry. It explain...

Case Studies

Reduce maintenance case study
This case study describes how Ajinomoto needed more dependable pH and DO sensors, plus less sensor maintenance, they turned to METTLER TOLEDO. Now, in...
Case Study on Optical DO Sensors in Fermentation
Novozymes is the world leader in the production of enzymes and has a global market share of more than 30%. Read in the case study how for Novozymes, o...

Accessories

Digital Sensor Integration

The M100 Sensor Mount (SM) is a single-channel transmitter for connecting ISM optical dissolved oxygen sensors to a biocontroller. The Bluetooth 4.0 interface is compatible with the PC-based and mobile versions of iSense software.

Material No.: 30365367

Sensor Calibration & Maintenance Tools

This is a USB iSense adaptor for connecting ISM RS485 sensors to iSense for pH, DO and CO₂ measurement and sensor calibration.

Material No.: 52300399

This is a USB iSense adaptor for connecting ISM RS485 VP sensors to iSense for pH, DO and CO2 measurement and sensor calibration.

Material No.: 30014134

A universal device for connecting both 1-wire and RS485 ISM sensors to a computer running iSense software.

Material No.: 30130631

Material No.: 52300400

Consumables

Software

Get Your Quote
DO Sensor InPro6860i/12/220/mA Ex
FDA