LightEdition pH Sensor: Good performance at an attractive price

LightEdition Sensor

Affordable and Reliable Sensors to Measure pH, Conductivity, Dissolved Oxygen and ORP

Analytical Instruments

Products and Specs

 
Filter:
Set filter
Clear All
 
Measuring range
Temperature Range
Connector
Cell type
Cell Constant
Material No.: 51340335
Measuring range0.01 – 200 mS/cm ;
Temperature Range 0 °C – 80 °C ;
ConnectorMini-DIN ;
Cell type4 graphite poles ;
Cell Constant0.55 cm-1 ;
Shaft MaterialEpoxy ;
Sensor Type4 graphite poles ;
Shaft length120 mm ;
Shaft Diameter 12 mm ;
Cable (Length) 1 m ;
ParameterConductivity ;
ISMNo ;
Temperature probeNTC 30 kΩ ;
For portable meterNo ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleGeneral Purpose ;
Cable and connectors1.0 m Mini-DIN ;
Base Unit Temperature Range (Metric)–0 °C – 80 °C ;
Type of junction
Reference System
Reference electrolyte
Membrane glass
Membrane resistance (25°C)
Reference electrolyte Order no.
Metal
Material No.: 51340336
Measuring range0.01 – 500 µS/cm ;
Temperature Range 0 °C – 60 °C ;
ConnectorMini-DIN ;
Cell type2 steel poles ;
Cell Constant0.08 cm-1 ;
Shaft MaterialPVC/Stainless Steel ;
Sensor Type2 steel poles ;
Shaft length120 mm ;
Shaft Diameter 12 mm ;
Cable (Length) 1 m ;
ParameterConductivity ;
ISMNo ;
Temperature probeNTC 30 kΩ ;
For portable meterNo ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleLow-ion strength (pure water) ;
Cable and connectors1.0 m Mini-DIN ;
Base Unit Temperature Range (Metric)–0 °C – 60 °C ;
Type of junction
Reference System
Reference electrolyte
Membrane glass
Membrane resistance (25°C)
Reference electrolyte Order no.
Metal
Material No.: 51340403
Measuring range1 – 20 mg / L ;
Temperature Range 0 °C – 50 °C ;
ConnectorBNC/RCA (Cinch) ;
Cell type
Cell Constant
Shaft MaterialPVC ;
Sensor TypeGalvanic ;
Shaft length120 mm ;
Shaft Diameter 12 mm ;
Cable (Length) 1 m ;
ParameterDO ;
ISMNo ;
Temperature probeNTC 30 kΩ ;
For portable meterYes ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleGeneral Purpose ;
Cable and connectors1.0 m BNC/RCA (Cinch) ;
Base Unit Temperature Range (Metric)–0 °C – 60 °C ;
Type of junction
Reference System
Reference electrolyte
Membrane glass
Membrane resistance (25°C)
Reference electrolyte Order no.
Metal
Material No.: 30266974
Measuring range0.01 – 200 mS/cm ;
Temperature Range 0 °C – 80 °C ;
ConnectorLTW (IP67) ;
Cell type4 graphite poles ;
Cell Constant0.55 cm-1 ;
Shaft MaterialEpoxy ;
Sensor Type4 graphite poles ;
Shaft length120 mm ;
Shaft Diameter 12 mm ;
Cable (Length) 2 m ;
ParameterConductivity ;
ISMNo ;
Temperature probeNTC 30 kΩ ;
For portable meterYes ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleGeneral Purpose ;
Cable and connectors2.0 m LTW, IP67 ;
Base Unit Temperature Range (Metric)–0 °C – 80 °C ;
Type of junction
Reference System
Reference electrolyte
Membrane glass
Membrane resistance (25°C)
Reference electrolyte Order no.
Metal
Material No.: 30266975
Measuring range1 – 20 mg / L ;
Temperature Range 0 °C – 50 °C ;
ConnectorBNC/RCA (Cinch) IP67 ;
Cell type
Cell Constant
Shaft MaterialPVC ;
Sensor TypeGalvanic ;
Shaft length120 mm ;
Shaft Diameter 12 mm ;
Cable (Length) 1 m ;
ParameterDO ;
ISMNo ;
Temperature probeNTC 30 kΩ ;
For portable meterYes ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleGeneral Purpose ;
Cable and connectors2.0 m BNC/RCA (Cinch), IP67 ;
Base Unit Temperature Range (Metric)–0 °C – 60 °C ;
Type of junction
Reference System
Reference electrolyte
Membrane glass
Membrane resistance (25°C)
Reference electrolyte Order no.
Metal
Material No.: 30259840
Measuring rangepH 1 – 11 ;
Temperature Range 0 °C – 50 °C ;
ConnectorBNC (IP67) ;
Cell type
Cell Constant
Shaft MaterialGlass ;
Sensor TypeCombined electrode ;
Shaft length17 mm ;
Shaft Diameter 6 mm ;
Cable (Length) 2 m ;
ParameterpH ;
ISMNo ;
Temperature probeNo ;
For portable meterYes ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleSemi-solid samples ;
Cable and connectors2.0 m BNC, IP67 ;
Base Unit Temperature Range (Metric)–0 °C – 50 °C ;
Type of junctionCeramic ;
Reference SystemAg/AgCl ;
Reference electrolyteGel ;
Membrane glassLoT ;
Membrane resistance (25°C)%3C 250 MΩ ;
Reference electrolyte Order no.
Metal
Material No.: 30247153
Measuring rangepH 0 – 14 ;
Temperature Range 0 °C – 80 °C ;
ConnectorBNC/RCA (Cinch) IP67 ;
Cell type
Cell Constant
Shaft MaterialPOM ;
Sensor TypeCombined electrode ;
Shaft length120 mm ;
Shaft Diameter 12 mm ;
Cable (Length) 2 m ;
ParameterpH ;
ISMNo ;
Temperature probeNTC 30 kΩ ;
For portable meterYes ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleGeneral Purpose ;water ;
Cable and connectors2.0 m BNC/RCA (Cinch), IP67 ;
Base Unit Temperature Range (Metric)–0 °C – 80 °C ;
Type of junctionPolyester ;
Reference SystemAg/AgCl ;
Reference electrolyteGel ;
Membrane glassU ;
Membrane resistance (25°C)%3C 250 MΩ ;
Reference electrolyte Order no.
Metal
Material No.: 51340348
Measuring rangepH 0 – 14 ;
Temperature Range 0 °C – 80 °C ;
ConnectorBNC/RCA (Cinch) ;
Cell type
Cell Constant
Shaft MaterialGlass ;
Sensor TypeCombined electrode ;
Shaft length120 mm ;
Shaft Diameter 12 mm ;
Cable (Length) 1 m ;
ParameterpH ;
ISMNo ;
Temperature probeNTC 30 kΩ ;
For portable meterNo ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleGeneral Purpose ;High-ion strength ;water ;
Cable and connectors1.0 m BNC/RCA (Cinch) ;
Base Unit Temperature Range (Metric)–0 °C – 80 °C ;
Type of junctionCeramic ;
Reference SystemAg/AgCl ;
Reference electrolyte3 mol/L KCl AgCl saturated ;
Membrane glassHA ;
Membrane resistance (25°C)%3C 600 MΩ ;
Reference electrolyte Order no.51343184 ;
Metal
Material No.: 51340330
Measuring rangepH 0 – 14 ;
Temperature Range 0 °C – 80 °C ;
ConnectorBNC ;
Cell type
Cell Constant
Shaft MaterialPOM ;
Sensor TypeCombined electrode ;
Shaft length120 mm ;
Shaft Diameter 12 mm ;
Cable (Length) 1 m ;
ParameterpH ;
ISMNo ;
Temperature probeNo ;
For portable meterNo ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleGeneral Purpose ;water ;
Cable and connectors1.0 m BNC ;
Base Unit Temperature Range (Metric)–0 °C – 80 °C ;
Type of junctionPolyester ;
Reference SystemAg/AgCl ;
Reference electrolyteGel ;
Membrane glassU ;
Membrane resistance (25°C)%3C 250 MΩ ;
Reference electrolyte Order no.
Metal
Material No.: 51340331
Measuring rangepH 0 – 14 ;
Temperature Range 0 °C – 80 °C ;
ConnectorBNC ;
Cell type
Cell Constant
Shaft MaterialGlass ;
Sensor TypeCombined electrode ;
Shaft length120 mm ;
Shaft Diameter 12 mm ;
Cable (Length) 1 m ;
ParameterpH ;
ISMNo ;
Temperature probeNo ;
For portable meterNo ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleGeneral Purpose ;High-ion strength ;water ;
Cable and connectors1.0 m BNC ;
Base Unit Temperature Range (Metric)–0 °C – 80 °C ;
Type of junctionCeramic ;
Reference SystemAg/AgCl ;
Reference electrolyte3 mol/L KCl AgCl saturated ;
Membrane glassHA ;
Membrane resistance (25°C)%3C 600 MΩ ;
Reference electrolyte Order no.51343184 ;
Metal
Material No.: 51340332
Measuring rangepH 0 – 14 ;
Temperature Range 0 °C – 80 °C ;
ConnectorBNC ;
Cell type
Cell Constant
Shaft MaterialGlass ;
Sensor TypeCombined electrode ;
Shaft length120 mm ;
Shaft Diameter 12 mm ;
Cable (Length) 1 m ;
ParameterpH ;
ISMNo ;
Temperature probeNo ;
For portable meterNo ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleWaste water, emulsions ;
Cable and connectors1.0 m BNC ;
Base Unit Temperature Range (Metric)–0 °C – 80 °C ;
Type of junctionMovable PTFE sleeve ;
Reference SystemAg/AgCl ;
Reference electrolyte3 mol/L KCl ;
Membrane glassHA ;
Membrane resistance (25°C)%3C 600 MΩ ;
Reference electrolyte Order no.51343180 ;
Metal
Material No.: 30089747
Measuring rangepH 0 – 14 ;
Temperature Range 0 °C – 80 °C ;
ConnectorBNC ;
Cell type
Cell Constant
Shaft MaterialGlass ;
Sensor TypeCombined electrode ;
Shaft length90 mm ;
Shaft Diameter 4.3 mm ;
Cable (Length) 1 m ;
ParameterpH ;
ISMNo ;
Temperature probeNo ;
For portable meterNo ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleSmall samples ;
Cable and connectors1.0 m BNC ;
Base Unit Temperature Range (Metric)–0 °C – 80 °C ;
Type of junctionCeramic ;
Reference SystemAg/AgCl ;
Reference electrolyteGel ;
Membrane glassU ;
Membrane resistance (25°C)%3C 250 MΩ ;
Reference electrolyte Order no.
Metal
Material No.: 51340333
Measuring rangepH 1 – 11 ;
Temperature Range 0 °C – 50 °C ;
ConnectorBNC ;
Cell type
Cell Constant
Shaft MaterialGlass ;
Sensor TypeCombined electrode ;
Shaft length17 mm ;
Shaft Diameter 6 mm ;
Cable (Length) 1 m ;
ParameterpH ;
ISMNo ;
Temperature probeNo ;
For portable meterNo ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleSemi-solid samples ;
Cable and connectors1.0 m BNC ;
Base Unit Temperature Range (Metric)–0 °C – 50 °C ;
Type of junctionCeramic ;
Reference SystemAg/AgCl ;
Reference electrolyteGel ;
Membrane glassLoT ;
Membrane resistance (25°C)%3C 250 MΩ ;
Reference electrolyte Order no.
Metal
Material No.: 51340242
Measuring rangepH 0 – 14 ;
Temperature Range 0 °C – 80 °C ;
ConnectorBNC/RCA (Cinch) ;
Cell type
Cell Constant
Shaft MaterialPOM ;
Sensor TypeCombined electrode ;
Shaft length120 mm ;
Shaft Diameter 12 mm ;
Cable (Length) 1 m ;
ParameterpH ;
ISMNo ;
Temperature probeNTC 30 kΩ ;
For portable meterNo ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleGeneral Purpose ;water ;
Cable and connectors1.0 m BNC/RCA (Cinch) ;
Base Unit Temperature Range (Metric)–0 °C – 80 °C ;
Type of junctionPolyester ;
Reference SystemAg/AgCl ;
Reference electrolyteGel ;
Membrane glassU ;
Membrane resistance (25°C)%3C 250 MΩ ;
Reference electrolyte Order no.
Metal
Material No.: 51340338
Measuring range-2000 – 2000 mV ;
Temperature Range 0 °C – 80 °C ;
ConnectorBNC ;
Cell type
Cell Constant
Shaft MaterialGlass ;
Sensor TypeCombined electrode ;
Shaft length120 mm ;
Shaft Diameter 12 mm ;
Cable (Length) 1 m ;
ParameterORP ;
ISMNo ;
Temperature probeNo ;
For portable meterYes ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleGeneral Purpose ;
Cable and connectors1.0 m BNC ;
Base Unit Temperature Range (Metric)–0 °C – 80 °C ;
Type of junctionCeramic ;
Reference SystemAg/AgCl ;
Reference electrolyte3 mol/L KCl AgCl saturated ;
Membrane glass
Membrane resistance (25°C)
Reference electrolyte Order no.51343184 ;
MetalPlatinum Pin ;
Material No.: 51340339
Measuring range-2000 – 2000 mV ;
Temperature Range 0 °C – 80 °C ;
ConnectorBNC ;
Cell type
Cell Constant
Shaft MaterialPOM ;
Sensor TypeCombined electrode ;
Shaft length120 mm ;
Shaft Diameter 12 mm ;
Cable (Length) 1 m ;
ParameterORP ;
ISMNo ;
Temperature probeNo ;
For portable meterYes ;
Maintenace-freeYes ;
Signal typeAnalog ;
SampleGeneral Purpose ;
Cable and connectors1.0 m BNC ;
Base Unit Temperature Range (Metric)–0 °C – 80 °C ;
Type of junctionPolyester ;
Reference SystemAg/AgCl ;
Reference electrolyteGel ;
Membrane glass
Membrane resistance (25°C)
Reference electrolyte Order no.
MetalPlatinum Pin ;
Comparison

Documentation

Product Information

LightEdition Sensors
Affordable and reliable – the LightEdition sensors are tailored for high price / performance ratio. The well thought trough construction is designed...

Services

800 METTLER (800 638 8537)
Call Service

Explore our Services - Tailored to Fit your Equipment

We support and service your measurement equipment through its entire life-cycle, from installation to preventive maintenance and calibration to equipment repair.

Uptime
Support & Repair
Performance
Maintenance & Optimization
Compliance
Calibration & Quality
Expertise
Training & Consulting
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.