Flash Differential Scanning Calorimetry (Flash DSC)

    Chip Calorimetry (Flash DSC)

    Flash Differential Scanning Calorimetry is the ideal addition to conventional DSC

     

    Flash Differential Scanning Calorimetry (Flash DSC)

    Flash DSC 1

    Differential Scanning Calorimetry, DSC, is the most important method in thermal analysis. It measures the heat flow to or from a sample as a function of temperature or time and thereby allows physical transitions and chemical reactions to be quantitatively measured.

     

    Flash Differential Scanning Calorimetry revolutionizes rapid-scanning DSC.

    The Flash DSC 1 can analyze reorganization processes that were previously impossible to measure. The Flash DSC 1 is the ideal complement to conventional DSC. Heating rates now cover a range of more than 7 decades.

     

    The Flash DSC 1 allows you to prepare samples with defined structures such as occur during rapid cooling in injection molding processes. The application of different cooling rates influences the crystallization behavior and structure of the sample. The use of high heating rates enables materials to be analyzed without interference from reorganization processes – there is no time for such processes to occur.

     

    Flash Differential Scanning Calorimetry is also the ideal method for studying crystallization kinetics.

    In conventional DSC instruments, the sample is measured in a crucible in order to protect the sensor. The heat capacity and thermal conductivity of the crucible however have a significant influence on the measurement. In the Flash DSC 1, the sample is placed directly onto the MultiSTAR chip sensor. The patented dynamic power compensation control circuit allows measurements to be performed with minimum noise level at high heating and cooling rates.

     

    Complete thermal analysis system

    A complete thermal analysis system comprises four different measurement techniques. Each characterizes the sample in a different way. The combination of all the results simplifies interpretation. Besides heat flow measurements using DSC or Flash DSC, the other instruments measure weight loss (TGA), change in length (TMA) or the  mechanical modulus (DMA). All these quantities change as a function of temperature.

     
     
    Products and Specs
     
    Cooling rates (typical)
    Heating rates (typical)
    Material No.: 51143059
    Cooling rates (typical)-6 K/min. (-0.1 K/s) … -240 000 K/min (-4 000 K/s)
    Heating rates (typical)30 K/min. (0.5 K/s) … 2 400 000 K/min (40 000 K/s)
    Comparison
     
     
     
     
     
     
     
    Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.