Melting Point, Boiling Point, Cloud Point, and Slip Melting Point | METTLER TOLEDO
Melting Point Excellence

Melting Point Excellence

Automatic melting point, boiling point, cloud point, and slip melting point determination

 

Automatic Melting Point Instruments

Unlike manual measurements which are time consuming and error prone, there is no need for continuous visual observation with our Excellence Melt...

Unlike manual measurements which are time consuming and error prone, there is no need for continuous visual observation with our Excellence Melting Point Systems. The measurement is done fully automatically, detection of transmitted light combined with video observation ensures that the melting point, melting range, slip melting point, boiling point, and cloud point measurements are reliable. Statistical evaluation with standard deviation and mean value.allow you to have full confidence in your data.

Ensure full compliance with the relevant international and national standards and norms, such as Ph.Eur. 2.2.60, USP<741>, Ch.P. 0612, and Japanese JIS


 

Products and Specs

 
Products and Specs
Filter:
Set filter
Clear All
 
Temperature Range
Number of One Clicks™
Application Type
Data Export
Heating Rate (/min)
Material No.: 30321330
See details
Temperature RangeRT – 300 °C
Number of One Clicks™12
Application TypeMelting Point; Slip Melting Point
Data ExportNo
Heating Rate (/min)0.1 °C – 20 °C
Cooling time (300°C to 50°C)4 min
Heating time (50°C to 300°C) (min)3
Number of Capillaries (2)2 Slip Melting Point Capillaries; 3 Melting Point Capillaries
PDF ReportsNo
Stored Methods0
Stored Results10
User ManagementMultiple Users
Substances in database0
Videocolor, 60 minutes
Material No.: 51142502
See details
Temperature RangeRT – 350 °C
Number of One Clicks™12 Per User
Substances in database5
Videocolor, 300 minutes
Material No.: 30321331
See details
Temperature RangeRT – 350 °C
Number of One Clicks™12 Per User
Application TypeMelting Point; Boiling Point; Cloud Point; Slip Melting Point
Data ExportTo SD Card or PC
Heating Rate (/min)0.1 °C – 20 °C
Cooling time (300°C to 50°C)5.5 min
Heating time (50°C to 300°C) (min)4
Number of Capillaries (2)3 Melting Point Capillaries; 2 Slip Melting Point Capillaries; 2 Boiling Point Capillaries; 2 Cloud Point Capillaries
PDF ReportsYes
Stored Methods20
Stored Results50
User ManagementMultiple Users; Password Protection; Protection of Settings
Substances in database6
Videocolor, 300 minutes
Material No.: 51142503
See details
Temperature RangeRT – 400 °C
Number of One Clicks™12 Per User
Substances in database100
Videocolor, 300 minutes
Comparison

Documentation

Brochures

Excellence Dropping Point Systems
The innovative DP70 and DP90 dropping point systems can determine dropping point and softening point of pitch, asphalt, polymers, resins, waxes and ma...
Excellence Melting Point Systems
Simple, efficient, and trustworthy, MP55, MP70, MP80 and MP90 melting point systems cover a wide range of applications and specifications, from meltin...

Applications

Dropping Point of Lubricating Grease
This site provides you valuable dropping and softening point application know how in the form of concise application notes.
Melting Point in Polymer Chemistry
This site provides you valuable dropping and softening point application know how in the form of concise application notes.
Dropping Point of edible oils and fats
This site provides you valuable dropping and softening point application know how in the form of concise application notes.
Dropping and Softening Point in Petrochemical Industry
This site provides you application-related white papers covering automatic melting, dropping and softening point measurements

Datasheets

MP55 Melting Point System
Simply to the point. Everything needed for the simple and automatic determination of melting point and slip melting points.
MP70 Melting Point System
Strong performance. The MP70 is the ideal choice for melting point and melting range determinations.
MP80 Melting Point System
Maximum flexibility. Optimized for diverse tasks, the MP80 offers One Click™ melting point, boiling point, cloud point and slip melting points.
MP90 Melting Point System
Efficiency at the highest level. The MP90 is optimized for the highest throughput.
LabX™ Thermal Values - Laboratory Software for Melting Point Excellence Systems
Professional PC laboratory software for MP70, MP80, and MP90
MP VPac™ Performance Verification
Performance verification by temperature calibration is the recommended workflow to ensure faultless routine operation of the melting point instrument...
Comprehensive and useful MP and DP accessories
The comprehensive and useful MP and DP accessories from METTLER TOLEDO facilitate and secure a crucial part of the melting, dropping or softening poin...
Equipment Qualification for Melting Point
Our EQPac service solution provides an onsite, fully-documented, professional installation and qualification service to ensure regulatory compliance a...

Case Studies

Analytical chemistry techniques
Insights into KF titration with Mapei. Coty's high efficiency quality assurance lab. Dihon Pharmaceuticals: automation of MP analyses. Comparative stu...
RNA quantification
Quantification of RNA, DNA and proteins with UV/VIS spectrophotometry. Ion analysis in the food industry. Enzyme kinetics with UV5Bio. Thermometric ti...
Thermal Analysis UserCom 8
Tips on Model Free Kinetics. Crucibles for high temperature TGA. Crucible lid with 50μm hole. Polymorphism using DSC. Swelling measurements of thi...
Better Base Numbers Through Fast Conductometric Titration
In theory, the measurement of the lubricant acid or base number by titration is straightforward. In practice, however, it is a challenging task. Impro...
Analytical Chemistry UserCom 6
The right electrolyte for every applicatio. Titration in the pharmaceutical industry. Fully automated, continuous and parallel determination of nick...
Analytical Chemistry UserCom 1
Memory Card application package: Methods on memory card. Titration in the Petroleum Industry: Determine key values for quality, quickly and precisely...
Analytical Chemistry UserCom 8
Control of "purified water" and "water for injection" to USP requirements. Fully automatic COD determination with Rondo60. The most frequent causes...
Analytical Chemistry UserCom 10
Sulfate determination. Analysis of dietary supplements: turbidimetric titration of chondroitin sulfate. Tips & Hints: How to transfer your density a...
Analytical Chemistry UserCom 9
In vino ... METTLER TOLEDO. Calcium analysis using a copper-sensitive electrode. Conductivity measurements - done properly! Automatic prevention of...
Analytical Chemistry UserCom 5
The new Rondo 60 Sample Changer: Three selected applications. X-mate Pro in the field. Powerful DL5x/DL7x calculation formulas - some examples. pH...

Services

800 METTLER (800 638 8537)
Call Service

Explore our Services - Tailored to Fit your Equipment

We support and service your measurement equipment through its entire lifecycle, from installation to preventive maintenance and calibration to equipment repair.

LabX® Software

LabX® Software fully supports 21 CFR part 11, EU GMP, and ISO 17025.

  • Events
  • Webinars
 
 
 
 
 
 
 
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.