IND131 DIN-mount terminal - Overview - METTLER TOLEDO

IND131 DIN-mount terminal

Space-saving terminal in a standard mounting format

The IND131 compact scale terminal is DIN rail mounted to ensure convenient mounting and location. Wiring connections and the operator interface are readily accessible on the front panel.
Specifications - IND131 DIN-mount terminal
Level Basic
Display OLED, 4 mm high
Interfaces Analog output, Allen-Bradley RIO, CC-Link, DeviceNet™, EtherNet/IP™, Modbus TCP, PROFIBUS® DP / ControlNet™
Degree of protection IP20, Type 1
Housings DIN rail-mount plastic
Applications Process weighing
A/D rate (int./ext) Internal: 366 Hz. Target comparison: 50 Hz. PLC interface 20 Hz
Dimensions 68 x 138 x 11 mm (2.7 x 5.4 x 4.4 inches)
Keyboard Zero, Tare, Clear, Print
Signal processing TraxDSP™ digital filtering
Resolution 100,000 divisions
Suitable platforms / weigh modules Analog load cells
Number of attachable platforms 1
Digital Input/Output Optional, relay or solid state, 2 inputs, 4 outputs
Mounting options DIN rail
Options COM2 RS-232/485 with support for Modbus RTU protocol + 4 discrete outputs (solid state or relay), 2 discrete inputs; PLC interface; 2GB SD memory card
Power Supply Universal AC or external DC

Special Features and BenefitsIND131 DIN mounting and chassis assembly


  • Split housing design uses two snap in place tabs for secure assembly and easy disassembly
  • Mounting designed for 35mm DIN rail
  • Secure installation using DIN rail retaining tab
  • Front panel display and 4-button interface for ease of service
  • Front panel access to SD Memory Card slot
  • Detachable terminal connectors
  •  Environmental protection rating IP20

Documentation

Product Brochures

Related Products and Solutions

Packaged Terminal Solutions - IND131 and IND331
IND131 and IND331 Industrial Process Terminals are available in packaged versions that can be pre-configured or customized.

Get Your Quote
IND131 DIN-mount terminal

Accessories

Get Your Quote
IND131 DIN-mount terminal

Standard Features and Benefits

  • Support for analog scale bases
  • Universal AC and DC (External supply) versions
  • Broad connectivity options
    • Serial  - RS-232 (standard) and RS-232/485 with support for Modbus RTU protocol (optional)
    • PLC – Analog Output / A-B RIO™ / Ethernet/IP™ / Modbus® TCP / PROFIBUS® DP / DeviceNet™ / ControlNet™
    • Discrete Inputs/Outputs
      • 2 Inputs /4 Outputs
      • Relay -- no external equipment required to control high voltage devices
      • Solid state -- open collector type
  • Optimum target control
    • Single-latched or coincidence target
    • Three coincidence comparators
    • Internal rate calculation assignable to comparators
  • Enhanced performance for process applications
    • Ultra-fast A/D conversion (366 Hz), target comparison (50 Hz) and PLC update (20 Hz) rates
    • Patented TraxDSP™ digital filtering
    • Display resolution 100,000d (max)
  • Enhanced productivity and efficiency
      • SD memory card
      • Backup and restore for setup and calibration
      • Portability of setup to other terminals
  • Calibration choices

    • Scale calibration though PLC
    • Step calibration
    • CalFREE® -Calibration without test weights
    • Traditional
  • Service friendly
    • Modular design assures ease of service and multiple mounting possibilities
    • Diagnostic LEDs and error codes for easy troubleshooting
    • TraxEMT™ performance monitoring and recording for easy operational audit
    • Serial and Discrete I/O tests
  • Weights and Measures Approvals
    • NTEP, Class III/IIIL 10,000d Coc 09-051
    • OIML, Class III 6,000e (R76/2006-NL 1-09.26)
    • MID, OIML R51/R61 
    • Canada Class III/IIIHD n max. 10000/20000
 
 
 
 
 
 
 
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.