ParameterISM 1-wire pH, amperometric oxygen and conductivity sensors
Klasifikácia nebezpečných oblastíATEX / IECEx Zone 1,
CSA Class I; II, III Div 1, Class 1, Zone 0,
NEPSI Ex Zone 1
Typ senzoraISM
KomunikácieHART®
ISM featuresPlug and Measure, DLI, ACT, TTM
EnclosureIP 66, NEMA 4X
Supply voltage14 – 30 VDC
Analog output1 × 4 to 20 mA (loop powered), galvanically isolated
Viac detailov
ParameterISM 1-wire pH, amperometric oxygen and conductivity sensors
Klasifikácia nebezpečných oblastíNo Hazardous Area Certifications
Typ senzoraISM
KomunikácieHART®
ISM featuresPlug and Measure, DLI, ACT, TTM
EnclosureIP 20
Supply voltage14 – 30 VDC
Analog output1 × 4 to 20 mA (loop powered), galvanically isolated
Viac detailov
ParameterISM pH, amperometric oxygen, and carbon dioxide sensors
Klasifikácia nebezpečných oblastíNo Hazardous Area Certifications
Typ senzoraISM
KomunikácieMODBUS RTU
ISM featuresPlug and Measure, DLI, ACT, TTM
EnclosureIP 67
MontážOn head of 1-wire sensor: AK9
Supply voltage24 VDC
Analog outputActive 2 × 4 to 20 mA, galvanically isolated to passive DCS card
Kompatibilita senzoraISM 1-wire pH, DO (amperometric) and carbon dioxide sensors
M100 SM 1-káblový30 365 366
Viac detailov
ParameterOptical oxygen sensors
Klasifikácia nebezpečných oblastíNo Hazardous Area Certifications
Typ senzoraISM
KomunikácieMODBUS RTU
ISM featuresPlug and Measure, DLI, ACT, TTM
EnclosureIP 67
MontážOn head of RS 485 sensor: VP8
Supply voltage24 VDC
Analog outputActive 2 × 4 to 20 mA, galvanically isolated to passive DCS card
Kompatibilita senzoraISM RS485 optical DO sensors
M100 SM 1-káblový30 365 367
Viac detailov
ParameterpH, CO₂, DO, Conductivity
Klasifikácia nebezpečných oblastíNo hazardous area certification
Typ senzoraISM
KomunikácieModbus RTU Protocol
MontážAK9 connector on head of 1-wire sensor
Porovnanie

Dokumentácia

Datasheets & Brochures

Datasheets for Sensor Mount Transmitter M100 SM
The M100 Sensor Mount (SM) is a single-channel transmitter. It allows the connection on biocontrollers of 1-wire ISM sensors for measuring pH, ampDO a...
Technical Data: M100 DR DIN Rail Transmitter for pH/ORP, pH/pNa, Oxygen and Conductivity
The M100 DR DIN rail transmitter is a 2-wire transmitter with HART® communication capability for analytical measurements. The M100 DR is a single-chan...

Instruction Manuals

Operating Instructions for Head Mount Transmitter M100
These operating instructions offer important notes on handling of the M100 transmitter of METTLER TOLEDO. A prerequisite for safe work is compliance w...
Operating Instructions: DIN Rail Transmitter M100 DR
These operating instructions offer important notes on handling of the M100 DR transmitter of METTLER TOLEDO. A prerequisite for safe work is complianc...
Instruction Manuals for Sensor Mount Transmitter M100 SM
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits ar...

Quick Setup Guides

Quick Setup Guide Transmitter M100
The M100 is a 2-wire head mount transmitter for analytical measurements with HART communication capabilities. The M100 is a single-channel, multi-para...
Quick Setup Guide: Transmitter M100/2H DR
The M100 DIN rail transmitter is a 2-wire transmitter for analytical measurements with HART communication capabilities. The M100 is a single-channel,...

Webové semináre

Webinar: Small Footprint Installation for Hazardous Areas
The continuous, real-time information that in situ analyzers provide has huge advantages over lab analyses of grab samples, and in the end leads to mu...

Videá

The world's first head mount analyzer transmitter
Watch the video to see how easy in-situ analysis becomes with the M100 head mount transmitter.

Služby

+421 2 4444 1220 - 2
Kontaktovať servis
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.