Manage your online profile and customize your mt.com experience
Before starting a moisture measurement, the right sample preparation is required. Depending on your sample, crushing, grinding or shaking can be the adequate procedure to get homogeneous samples. Besides the sample preparation, proper sample handling is a key factor for repeatable and accurate results. In this video, we want to show you which points you should pay attention to. Aluminum sample pans play a vital role in the accuracy of a moisture content measurement. Before starting a new measurement, check your aluminum sample pan. Oils or greases on new sample pans is a sign for poor material and production quality. Oily residues from the production process or wrong pan diameter falsify the results. Sample residues from reused sample pans can contain moisture which is influencing the moisture measurement of the next samples. For samples that can be removed easily, be aware that tiny residues always remain. To avoid false results, change your sample pan regularly. Sample pans that have been deformed by multiple reuse prevent an even distribution of sample and thus heat. Mettler Toledo, a supplier of the aluminum sample pans, guarantees consistent quality made in Switzerland. Take an adequate amount of sample, typically 3 to 5 grams, which covers the bottom of the aluminum sample pan and distribute evenly. An evenly spread sample results in a homogeneous distribution of heat throughout the sample and the moisture can diffuse evenly out of it. Choose the right amount of sample and distribute it by gentle shaking. Glass fiber filters are used for measuring samples with a moisture content over 30%, typically liquid and pasty samples. They prevent film building and reduce the measurement time of liquids by up to 50% by enlarging the sample surface area and distributing the sample evenly. Avoid problems before they arise by using the right accessories. Check your aluminum sample pans before starting a measurement. And speed up your moisture determination by using glass fiber filters for liquid and pasty samples.
Both accuracy and repeatability of moisture results can be improved with the ideal handling and preparation of a sample.

To speed up the analysis of liquid and pasty samples, glass fibre filters help increase the surface area and prevent pooling.

The ergonomic stand and printer holder for HX204 and HS153, improve posture at work.

The dust filters, together with the dust filter housing, protect the moisture analyzers in powdery or greasy environments.

Thanks to a flat stainless steel surface, you can clean the instrument quickly and easily.

The special gold-coated sample pan is the ideal accessory to contain textiles or other voluminous samples and achieve repeatable results.

Tricky samples that contract upon heating are best controlled with the combination of a sample pan, a glass fiber filter, and the downholder.

Be compliant and ensure ongoing instrument performance with SmartCal, a simple 10-minute test that verifies overall moisture analyzer performance.
METTLER TOLEDO's moisture analyzers deliver fast, precise, and reliable moisture determination results thanks to halogen heating and advanced weighing technologies.
Discover SmartCal, the unique test substance that enables you to verify the performance of your moisture analyzer with a simple 10-minute test. Test at point of use to ensure trusted moisture determination results.
The Good Moisture Analysis Practice Recommendation helps you find the right moisture analysis equipment based on your process requirements.
Learn more about moisture analyzers and moisture analysis in different industries. Get valuable information on drying method development and correct routine testing to ensure accurate and reliable moisture content results.
Ensure you get the right moisture analysis solution. Our white paper presents a scientific risk-based approach to instrument selection and ensuring accuracy.
The guide to moisture analysis assists you in reliably determining moisture content with a halogen moisture analyzer and covers various topics, including method development and routine testing.

SmartCal™ is an innovative test substance that offers a fast and efficient way to verify moisture analyzer performance. Testing your moisture analyzer regularly with SmartCal ensures that your measurements are reliable and fulfill the demands of your industry’s regulations. Select the integrated SmartCal method on the instrument, distribute the contents of the test sachet evenly over the sample pan, and start the measurement. After ten minutes, you know if your instrument’s performance is satisfactory or not. METTLER TOLEDO offers standard and certified SmartCal options, as well as SmartCal StarterPacs.
The key to correct moisture determination is a correct sample preparation and distribution. Samples need to be homogeneous and small, typically of a weight of no more than 3-5 g. Moreover, you should always use clean and dry sample pans - METTLER TOLEDO aluminium sample pans ensure optimal conditions for moisture determination and glass fibre filters help with measuring the moisture of liquid substances. Additionally, we offer a textile cage for bulky samples (HA-Cage) and a specially designed downholder, which ensures the samples remain in the correct position.
METTLER TOLEDO offers the complete range of moisture analyzer accessories required for accurate and repeatable measurements. Thanks to their perfect surface finish, the aluminium sample pans ensure optimal testing conditions. The glass fibre filters prevent film-building and simplify the testing of liquid and pasty substances. The dust filter protects the moisture analyzer in harsh production environments.