The purpose of the experiment was to investigate whether the adhesive bonds between metal parts had been sufficiently cured. This can be easily done using DSC measurements. For comparison, a good and a bad bond were measured.
DSC has the advantage that only small amounts of material are used for measurements. Faulty adhesive bonds can therefore be analyzed afterward by taking a small sample of the adhesive from the bond.
A two-component epoxy resin was used to bond two metal parts. When the parts were used, it became clear that some of the bonds failed at slightly elevated room temperatures.
Handbook | | Page | | Keywords |
Thermosets 2 | 100 | thermoset, curing, DSC, two-component resin, adhesive, quality assurance, |
Quality Assurance, Failure Analysis of Adhesive Bonds | Thermal Analysis Application No. HB 66 | Application published in METTLER TOLEDO TA Application Handbook Thermosets Volume 2