Single-use Sensors
Single-use Sensors

Single-use Sensors for Bag Manufacturers

pH and Dissolved Oxygen for stirred Single-use Reactors (> 20 L)

Designed for Single-Use Bag Manufacturers
Easy and Safe Installation and Integration
Reliable, Straightforward Use in Biocontrollers

Modele i dane techniczne

 
Modele i dane techniczne
Filtr:
Ustaw filtr
Wyczyść
 
Dane techniczne
Zakres pomiaru
Zobacz szczegóły
Dane techniczneConventional pH sensor with pH sensitive membrane glass
Zakres pomiarupH 3-10
Elementy detekcyjneGlass pH and Reference Electrodes, Lead-Free
Zintegrowany czujnik temperaturyPt1000
Punkt zerowy7.20 ±0.25 pH
Calibration1-point process
Materiały korpusuHigh density polyethylene, USP 88 class VI
O-ring materialEPDM, USP 88 class VI
Process connections Eldon James 1' port disc, with retainer
Sterylizowanie promieniami gamma25…45 kGy
Operating Temperature5…60°C (41…140°F)
Storage temperature5…25°C (41…77°F)
Mechaniczna odporność na ciśnienie"2 barg / 40 °C (29 psig / 104 °F), 1 barg / 60 °C (15 psig / 140 °F)"
ZatwierdzeniaUSP 88 class VI for all wetted polymer parts, factory calibration
Zobacz szczegóły
Dane techniczneOptical dissolved oxygen sensor
Zakres pomiaru0…250% air
Elementy detekcyjneOptical spot (Fluorescensce quenching)
Zintegrowany czujnik temperaturyPt1000
Calibration1-point air
Materiały korpusuHigh density polyethylene, USP 88 class VI
O-ring materialEPDM, USP 88 class VI
Process connections Eldon James 1' port disc
Sterylizowanie promieniami gamma25…45 kGy
Operating Temperature5…60°C (41…140°F)
Storage temperature5…25°C (41…77°F)
Mechaniczna odporność na ciśnienie"2 barg / 40 °C (29 psig / 104 °F), 1 barg / 60 °C (15 psig / 140 °F)"
ZatwierdzeniaUSP 88 class VI for all wetted polymer parts
Porównanie

Dokumentacja

Application Note

Application Note: Differences in Operation Between Analytical Multi-Use and Single-Use Sensors in Bioreactors
This application note provides information on the important trend towards the deployment of single-use bioreactors (SUBs) in the bioprocess industry....

Dane techniczne

Technical Data: InSUS x07 Sensor Series
The InSUS™ x07 sensor series for single-use technology bioprocesses cover the measurement parameters pH and dissolved oxygen (DO).

Instruction Manuals

Instruction Manual: InSUS Head for Optical Single-Use O₂ Sensors
These operating instructions contain all the information needed for safe and proper use of the optical sensor head.
Instruction Manual: Information for InSUS fiber optic cable
The enclosed adapter must be used, if the fiber optic cable is connected to sensors of the type InSUS 607. Mount the adapter – as shown in the photos...
M300 / M400 2G Quick Calibration Guide For pH Single-Use Sensors Type InSUS 307
METTLER TOLEDO InSUS™ pH sensors are analog, gamma irradiation-sterilizable single-use pH sensors with an integrated Pt 1000 temperature probe.

Usługi serwisowe

+48 22 440 67 66
Zadzwoń do serwisu
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.