Melting Point System MP90 - Overview - METTLER TOLEDO

Melting Point System MP90

Efficiency at the Highest Level.Optimized for highest throughput, the MP90 offers simultaneous determination of up to 6 melting point/melting range samples up to a maximum temperature of 400°C/750°F.

Simple One Click™ Operation

The One Click™ user interface enables users to start measurements with a single click of the button.

Color video recording

With the high resolution on-screen video, measurements can be observed in real time or conveniently replayed to verify the results.

Trusted performance

With the automatic detection of transmission intensity, highly accurate melting points or melting range temperatures are obtained.

Material No.: 30578105

Call for Quote
Specifications - Melting Point System MP90
Temp. Range
RT – 400°C
Number of One Clicks™
12 Per User
Application Type
Melting Point
Min. Number of Melting Point Capillaries
6 Melting Point Capillaries
Min. Cooling Time (Tmax to 50°C)
6 min
User management
Password protection
Protection of Settings
Multiple Users
Min. Heating Time (50°C to Tmax)
5 min
Data Export
to SD Card, USB Stick or PC
Heating Rate (/min)
0.1 °C – 20 °C
Stored Methods
60
PDF Reports
Yes
Stored Results
100
Compliance / Data Security
Audit Trail (requires LabX software)
21 CFR part 11 / EU Annex 11 (requires LabX software)
Substances in database
100
Video
color, 300 minutes
Languages
English, Chinese, German, Spanish, French, Italian, Portuguese, Russian, Japanese, Korean
Display / User interface
7" color display with touchscreen
PC Software
LabX Express and Server
LIMS Connectivity
Yes
PC Software (optional)
Yes
Dimensions (Width x Height x Depth)
18 x 35 x 19 cm
Weight
4 kg
Standard compliance
www.mt.com/mpdp-norms

Comprehensive and intuitive operation

The large color display and touch screen with the intuitive One Click™ user interface minimizes training and operator influence. Quick familiarization is guaranteed with the common user interface for all Analytical Laboratory instruments.

Maximum efficiency

Simultaneous measurement of up to 6 samples saves valuable time and effort. Short heating and cooling times allow more analyses to be performed in a shorter period of time.

Fast and accurate sample preparation

The accessory box contains all the tools you require for correct sample preparation and handling. The innovative sample preparation tool simplifies the filling process and allows simultaneous insertion of multiple capillaries.

Conformity with current standards

Full support to comply with the relevant international and national norms and standards, such as Ph. Eur., USP, ChP, and JIS is ensured.

User Management

Instrument settings can be personalized with shortcuts and the selected operator language. The user management system allows different levels of access to be defined, protecting critical data.

Data integrity and traceability

LabX® PC software conveniently manages measurement results, offers full support to comply with the 21 CFR Part 11 regulations, and enables a smooth and seamless LIMS/SAP integration.

Quick and simple calibration

Pre-programmed calibration and adjustment routines are available on the instrument. For instrument performance verification, the ready-to-use VPac™ verification kit is offered, containing prefilled capillaries of certified reference substances.

Documentation

Product Brochures

Brochure – Melting Point Excellence
Simple, efficient, and trustworthy, MP30, MP55, MP70, MP80 and MP90 melting point systems cover a wide range of applications and specifications, from...

Applications

Melting and Dropping Point Applications
Search for specific applications for Melting Point, Melting Range, Boiling Point, Cloud Point and Slip Melting Point and Dropping Point

UserCom

Analytical Chemistry UserCom Overview
Expert Tips, Product News and Applications for Analytical Chemistry — Titration, pH, Density & Refractometry, Melting & Dropping Point, UV/VIS Spectro...

Datasheets

Datasheet – MP90 Melting Point System
The MP90 is optimized for the highest throughput.

Accessories

Accessory Box, USP Melting Point
Robust and smart sample preparation tools packed in a compact accessory box, including USP melting point reference standards.

Material No.: 30312725

Corded barcode reader for the reading of 1D / linear codes

Material No.: 21901297

Calibration Substance MP VPac
MP VPac ready-to-use reference substance kit for performance verification of Melting Point Excellence Instruments

Material No.: 30097033

Dot matrix printer, USB interface, print speed 2.3 lines per second, auto settings detection

Material No.: 30702998

Consumables

Certified Reference Standards

High-purity reference substances, traceable to LGC standards, enable accurate temperature calibration and adjustment for Melting Point and Dropping Point Excellence instruments in the range of 40 - 360 °C.

Material No.: 30034252

High-purity reference substances, traceable to LGC standards, enable accurate temperature calibration and adjustment for Melting Point and Dropping Point Excellence instruments in the range of 40 - 360 °C.

Material No.: 18870

High-purity reference substances, traceable to LGC standards, enable accurate temperature calibration and adjustment for Melting Point and Dropping Point Excellence instruments in the range of 40 - 360 °C.

Material No.: 51143093

High-purity reference substances, traceable to LGC standards, enable accurate temperature calibration and adjustment for Melting Point and Dropping Point Excellence instruments in the range of 40 - 360 °C.

Material No.: 18555

High-purity reference substances, traceable to LGC standards, enable accurate temperature calibration and adjustment for Melting Point and Dropping Point Excellence instruments in the range of 40 - 360 °C.

Material No.: 30130597

High-purity reference substances, traceable to LGC standards, enable accurate temperature calibration and adjustment for Melting Point and Dropping Point Excellence instruments in the range of 40 - 360 °C.

Material No.: 30130598

High-purity reference substances, traceable to LGC standards, enable accurate temperature calibration and adjustment for Melting Point and Dropping Point Excellence instruments in the range of 40 - 360 °C.

Material No.: 51143091

High-purity reference substances, traceable to LGC standards, enable accurate temperature calibration and adjustment for Melting Point and Dropping Point Excellence instruments in the range of 40 - 360 °C.

Material No.: 30130599

High-purity reference substances, traceable to LGC standards, enable accurate temperature calibration and adjustment for Melting Point and Dropping Point Excellence instruments in the range of 40 - 360 °C.

Material No.: 51143095

High-purity reference substances, traceable to LGC standards, enable accurate temperature calibration and adjustment for Melting Point and Dropping Point Excellence instruments in the range of 40 - 360 °C.

Material No.: 30130610

High-purity reference substances, traceable to LGC standards, enable accurate temperature calibration and adjustment for Melting Point and Dropping Point Excellence instruments in the range of 40 - 360 °C.

Material No.: 18872

High-purity reference substances that enable accurate temperature calibration and adjustment of melting point devices in accordance with USP <741>.

Material No.: 30312726

High-purity reference substances that enable accurate temperature calibration and adjustment of melting point devices in accordance with USP <741>.

Material No.: 30312727

High-purity reference substances that enable accurate temperature calibration and adjustment of melting point devices in accordance with USP <741>.

Material No.: 30312728

Melting Point Performance Verification

Calibration Substance MP VPac
MP VPac ready-to-use reference substance kit for performance verification of Melting Point Excellence Instruments

Material No.: 30097033

Software

Get Your Quote
Melting Point System MP90