Extremely convenient transmitter configuration tool software enables instrument setup to be completed on a PC and then downloaded into the instrument. This can save many hours pushing buttons, especially when configurations are duplicated on multiple transmitters or multiple systems. The software also provides secure backup configuration for the end-user on site.
- Configure transmitter firmware offline using a personal computer (PC).
- All transmitter keypad programmable features can be done on the PC.
- Upload PC configurations to a transmitter.
- Download transmitter configurations to PC.
- Save application specific configurations in a library folder on the PC for future use.
- Print transmitter configurations to a txt file.
- Transmitter calibration factors can be printed to a txt file.
- Simple data logging of data stream.
- Simple easy-to-use software.

The Complementary Transmitter Configuration Tool (TCT) is available for M200, M300, and M800 transmitters on MT.com. This software works with single or multiple transmitters, allowing modification and archival of configuration files on Windows PCs. It also enables offline management, reducing the risk of programming errors. Configuration files can be printed or shared digitally. To get started, navigate to the folder where existing configuration files are stored to open a previously saved example, or create a new one from scratch. In this case, we'll amend a set that we get from a transmitter. Connect the PC via USB to the transmitter's USB B port and download the configuration files from the transmitter. While we are connected to the transmitter, we can also use the TCT to perform date-time synchronizations with the PC. Now we can navigate to a designated location on the PC to save the configuration files. At this point, it's possible to disconnect the transmitter and continue working on the configuration files. If we want to modify a previously saved configuration set, it can be opened here, but in this case we will select the files we just saved. Now we can configure the transmitter file using the toolbar on the left. First the Channel tab. We'll set a custom descriptor for this channel. and then proceed to set up the measurements available for the channel. The range, resolution, and filter for each measurement can also be adjusted. Moving to the Display tab, the display settings can be configured in various ways. We'll customize the instrument tag name and set the display mode to one channel. In the Parameter tab, the sensor measurements can be further customized. We'll set the uniconde conductivity sensor with standard temperature compensation on M1 and no temperature compensation on M3. In the Analog Outputs tab we can assign and configure analog outputs for the measurements. In this case we'll assign a measurement stream from the unicorn sensor to two of the available analog output channels and use the default range settings. In the Setpoint or Relay tab we can program setpoints and link activation status to customizable relay outputs available on the transmitter. Standard range types are available with simple input of the factor. The factors here ; but in this case we will be turning the c h two set point off and need to free the associated relay from the set point. We'll configure set point one to track c h one m one and make use of the special Unicon set points. This transmitter will use u s p six forty five limits for conductivity and just like that no further action is required to alert us if the sensor exceeds the limits established in the pharmacopeia. In the alarm clean tab system level alarms can be set and assigned to alarm output relays. We'll set a general alarm to trigger inverted on relay number one in the event of either power or software failure. In the sensor alarm tab we can modify the delay and state settings of the alarm output relays as they relate to sensors. The hold relay can also be managed here. We'll set the sensor disconnected event to trigger an alarm. In the User Management tab, we can enable password protection and create and modify additional users. We'll customize the user ID, change the user password, and configure the access restrictions to only certain menus in the transmitter. Now that our modifications are complete, we can save the configuration files. We will overwrite the files we initially extracted. To upload these settings, connect the PC via USB to the transmitter's USB-B port and press the button to send all transmitter setup files. The configuration can be uploaded to multiple transmitters sharing the same part number. Use the EXIT button to quit the TCT application. A warning will appear, reminding you to save the configuration and to confirm your action.