METTLER TOLEDO offers a wide range of high-quality balances and scales. However, which one fits your intended purpose?
We can help you select the right weighing device by matching a device’s performance and characteristics to your requirements with our GWP™ Recommendation service. This service is free of charge, tailored to your needs, and easy to apply – providing you with the security you need before making a purchase decision.
Why does it make sense? Having a fit-for-purpose balance or scale will help you to ensure consistent quality, reduce costs and maintain compliance.
Пожалуйста, расскажите о вашей задаче. /content/kz/ru/home/service/good-weighing-practice/how-to-choose-a-balance-or-scale.fb.6.pagetitleandimage.form.c.12.html
Key Factors for Choosing the Right Balance or Scale
What questions need to be answered to find your ideal balance or scale? GWP Recommendation considers the following:
Maximum weight: The maximum load you weigh (including the tare container)
Smallest net weight: The smallest load you weigh (excluding the tare container)
Weighing tolerance and regulations: The acceptable weighing error, specified as ± percentage; often derived from standards and/or regulations (e.g. legal-for-trade, ISO, etc.)
Safety factor: Considers the environment and external device influences (e.g. vibrations, drafts, number of operators, etc.)
Your local METTLER TOLEDO representative can help you answer these questions.
What You Get From the Selection Document
GWP Recommendation gives you assurance that the chosen device is fit for your intended purpose and will provide the accuracy level and performance you need it to. Your audit-proof selection document contains:
All information and requirements (yours and the recommended device's)
Services that will help to keep the device in top shape
Are you unsure about your weighing tolerance? We can help with our Uncertainty Calculator. Simply provide the cost of a sample, and our unique Uncertainty Calculator, based on the GWP Recommendation, will calculate the exact costs associated with measurement uncertainty at any point within the weighing range of a specific balance or scale. This gives you a clear basis to decide which weighing instrument best fits your needs and budget.
Do you know that even the smallest oversight in configuration can result in weighing errors? Our installation and qualification services ensure your laboratory balance or industrial scale meets your process requirements from day one.
Do you know if your weighing results are not only accurate, but accurate enough for you? Find the balance or scale calibration and tolerance assessment that is right for your processes.
Do you need help defining the right calibration frequency and routine testing plan details? Let us help with quality assurance plans tailored for your balances and scales to ensure you get the ongoing accuracy you need.
FAQ
1. What is a weighing tolerance? How do I define my weighing tolerance?
Здравствуйте и добро пожаловать в серию видеороликов good weighing practice. В этом видео подчеркивается важность взвешивания и то, какое влияние оно может оказать на качество продукции компании, соответствие нормативным требованиям и экономические цели, если оно выполняется неточно. В этом видео я хотел бы объяснить, что такое допуск взвешивания и как его определить. Все весы производственные, выпускаемые Mettler Toledo, отличаются высочайшим качеством. Однако какие из них достаточно точны для предназначенной им цели взвешивания? Представьте, что вы хотите покрасить стену в гостиной в определенный оттенок синего. Чтобы убедиться, что получаемый цвет будет таким же, как выбранный вами по колеровочной карте, производитель краски должен иметь допуск взвешивания. Что бы вы почувствовали, если бы конечный цвет вашей стены отличался от цвета, который вы выбрали в магазине красок? Эта диаграмма показывает, как могут выглядеть цвета, если допуски взвешивания или измерения отличаются на 1%, 5%, 10%. Если это произойдет, у производителя краски, безусловно, будет подмочена репутация, а также возникнут потери материала, поскольку пигменты были взвешены неточно. Это пример того, как весы производственные, при неправильной покупке или использовании, могут способствовать выпуску некачественной продукции и связанным с этим затратам. Что, если ошибка возникнет в форме обезболивающей таблетки или в количестве упрочняющего материала в партии бетона? Последствия могут быть гораздо хуже. Чтобы лучше объяснить допуск взвешивания, продолжим пример с цветом краски. Допустим, вы хотите взвесить 100 граммов. Можете ли вы принять ошибку взвешивания в 1 грамм, то есть считать допустимым диапазон от 99 граммов до 101 грамма? Если да, то это составляет допуск взвешивания 1%. При допуске взвешивания 1% и стоимости материала этого пигмента денежные потери могут составить $72,000 в год. При допуске взвешивания 10% вы фактически заявляете, что можете принять результат в диапазоне от 90 граммов до 110 граммов. При таком допуске годовые потери могут составить $720,000. Кроме того, при выборе подходящего допуска взвешивания следует учитывать и эти качественные аспекты. Чем сильнее неточное измерение может повлиять на людей, окружающую среду или ваш бизнес, тем более строгим должен быть ваш допуск взвешивания. Для фармацевтического контроля качества — 0.1%. Для обычных требований к качеству обычно используют 1%. Для недорогого материала с низкой эффективностью — 5%. Очень часто предприятия по производству ароматизаторов, продуктов питания и химической продукции работают с жесткими допусками, чтобы гарантировать, что наши любимые духи, шоколад и чистящие средства будут одинаковыми в каждой производственной партии. Ознакомьтесь с этим Руководством по допуску взвешивания для получения дополнительной информации или свяжитесь с нами для дальнейшей поддержки в определении допуска взвешивания, который подходит именно вашему бизнесу. Опираясь на проверенные научные принципы, Mettler Toledo может помочь вам выбрать подходящее взвешивающее устройство, предоставив бесплатный отчет-рекомендацию GWP. Мы также можем помочь вам определить, подходят ли установленные у вас весы производственные и весы производственные для поставленной задачи, с помощью уникальной услуги GWP verification. В результате вы можете быть уверены, что ваши взвешивающие устройства соответствуют требованиям к качеству вашей продукции и анализов. Чтобы узнать больше, посмотрите другие видео в нашей серии Good Weighing Practice.
What accuracy is required to guarantee the quality of your weighing task? And what plus/minus range on results would still be acceptable for quality or regulatory requirements? These answers define your weighing tolerance.
Weighing tolerance can depend on factors such as cost of material, applicable regulations, safety concerns related to weighing errors, environmental impact of wrong measurements, and more. An example: 100 kg weighed with a +/- of 1 kg is a 1 % weighing tolerance. Typical tolerances are from 0.1 % to 5 %.
Watch the video to learn more about weighing tolerances!
2. What is a safety factor? How can I find out what safety factor to apply?
Здравствуйте и добро пожаловать в серию видеороликов Good Weighing Practice. В этом видео подчеркивается важность взвешивания и то, какое влияние оно может оказать на качество продукции, соблюдение нормативных требований и экономические цели предприятия, если оно выполняется неточно. В этом видео я хотел бы объяснить, что такое коэффициент запаса, как его определить и почему его применение имеет смысл. Все весы и весы производственные, выпускаемые Mettler Toledo, отличаются высочайшим качеством. Однако какие из них достаточно точны для своего предназначенного взвешивания? Чтобы лучше понять коэффициент запаса, рассмотрим ситуацию, в которой у вас важная встреча в 3 часа. На автомобиле обычная поездка занимает один час. Если улицы покрыты снегом или если вам предстоит ехать в час пик, вместо того чтобы выехать в 2 часа, вы выехали бы в 1 час. По сути, вы использовали коэффициент запаса, чтобы гарантировать прибытие вовремя. В лаборатории или на производственном участке изменения окружающей среды менее заметны. Важно понимать, что при изготовлении взвешивающего устройства его характеристики испытываются в контролируемых условиях на предприятии Mettler Toledo и сравниваются с установленными допусками. Например, учитываются и контролируются следующие внешние воздействия. Влажность. Температура, вибрация, сквозняки, электростатические и магнитные воздействия. После установки новых весов или весов производственных у вас на объекте важно использовать коэффициент запаса, чтобы компенсировать эти внешние воздействия. Отсутствие коэффициента запаса может привести к результатам аналитических испытаний, выходящим за пределы спецификации, или к низкому качеству производственных партий. Так как же определить подходящий коэффициент запаса для устройства? Даже если окружающая среда стабильна, коэффициента запаса ниже 2 обычно недостаточно из-за долгосрочной нестабильности. В обычной лаборатории коэффициент запаса 2 должен быть подходящим, если конечный пользователь хорошо обучен, а взвешиваемый материал стабилен. В производственной среде часто требуется коэффициент запаса 3 или более, чтобы учесть большое количество возможных внешних возмущений. В случаях, когда речь идет о постоянном использовании, высокой проходимости или портативных весах, может потребоваться коэффициент запаса от 4 до 10. Ознакомьтесь с этим руководством. В нем содержится дополнительная информация о коэффициенте запаса. Или вы можете обратиться в Mettler Toledo за дальнейшей поддержкой, чтобы помочь определить коэффициент запаса, подходящий для вашего процесса взвешивания. Кроме того, помните, что Mettler Toledo может дать рекомендации по снижению внешних воздействий и их влияния на взвешивание с помощью наших специальных решений и наших аксессуары весы. На основе проверенных научных принципов Mettler Toledo может помочь вам выбрать подходящее взвешивающее устройство и бесплатно предоставить отчет с рекомендацией GWP. Мы также можем помочь вам определить, подходят ли установленные у вас весы и весы производственные для поставленных задач, предлагая уникальную услугу под названием GWP Verification. В результате вы можете быть уверены, что ваши взвешивающие устройства соответствуют требованиям к качеству вашей продукции и анализов. Чтобы узнать больше, посмотрите другие видео в нашей серии видеороликов Good Weighing Practice.
A safety factor ensures reliable results. It accounts for changing external influences such as vibrations, drafts, operators, etc. For normal, stable conditions, METTLER TOLEDO recommends a safety factor of at least 2 for laboratory and 3 for industrial environments. For unstable weighing conditions (e.g. a fume hood or harsh production environment) a higher safety factor should be applied.
Watch the video to learn more about safety factors and which safety factor is right for you!
4. Is a GWP Recommendation important if I do not work in a regulated industry (like pharma or biotech)?
Regardless of industry, weighing is considered a critical control point for many laboratory and industrial weighing processes. It impacts product quality and can cause waste, rework or overfilling.
It is important to pay specific attention to weighing, as weighing is often the beginning of your value chain. Any error at the weighing stage can become magnified in downstream analysis or processing.
GWP Recommendation helps you get rid of this risk by finding the balance or scale that fits your specific needs and requirements.
5. I have a unique weighing application. Can a GWP Recommendation still help me?
Your GWP Recommendation is a direct output of your conversation with our weighing experts. Help us understand what you are weighing and how, and we will provide the best solution documented in a GWP Recommendation report.
Запросить цены или информациюПолучить расчет стоимостиМгновенный расчет стоимостиИнформация об оборудованииRequest Online Demo
Я хочу...
Need assistance? Our team is here to achieve your goals. Speak with our experts.