RC1e Small Scale Production Workstation - 단종 제품

Small Scale Manufacturing - Safe and Reproducible

  • Production of high value chemicals at small scale in early phase process development                      
  • Ready-to-use manufacturing for automated and semi-automated operation
  • Precise control coping with vigorous reaction conditions


The RC1e Small Scale Production Workstation ensures:

  • Small scale manufacturing under safe conditions
  • Reliable and efficient process control
  • Reproducible and consistent batches
  • Process safety with no exposure to dangerous chemicals
  • Timely and efficient production at low cost

Small Scale Manufacturing - Safe and Reproducible

Thermostat and Reactor

  • Powerful heating and cooling
  • Intrinsically safe operation
  • Emergency programs to handle unexpected events
  • Operates like plant equipment
  • Collects and stores process data


Variables and Control

  • Accurate control of process parameters, including temperature, addition, pH
  • Precise addition by weight or volume
  • pH measurement and control
  • PID control for special applications
  • Seamless intergration with any iC software


iControl RC1 Software and Data Handling

  • Interactive process diagram
  • Direct and automated control
  • Recipe builder
  • Reaction editor and chemistry table
  • Chemical database
  • Compelling data and trend display
  • Fast and easy data evaluation
  • Secure and traceable data storage

단종일: Dec, 2014

견적 문의

대체할 문구: RC1mx and HFCal

스케일에서 안전 공정 개발

스케일에서 안전 공정 개발.HFCal 옵션 포함 RC1mx 반응 열량계

공정 이해도

열역학 정보를 등온 또는 비등온 조건 하에서 빠르고 정확하게 판별함

열 흐름 열량계 - 신뢰성 제공

외부 영향의 간섭 없이 강력하며, 열 흐름 열량은 공정 조건 하에서 열 방출을 정확하고 정밀하게 측정합니다.

실제 반응열 측정

"완전한" 반응열을 측정하는 것은 화학 반응의 진행과 동역학 및 잠재적 유해성을 이해하기 위한 기본 입니다.

액세서리 - RC1e Small Scale Production Workstation

Specifications - RC1e Small Scale Production Workstation

Thermostat
Temperature Range-50°C to 230°C (jacket temperature)
(optional temperature ranges from -70°C to 300°C)
Control Modesisothermal and isoperibolic, constant or ramp, adiabatic, reflux, distillation and crystallization
ResolutionTr = 0.2 mK, Tj 10 mK (T<100°C)
Tr = 1 mK, Tj = 10 mK (T>100°C)
Stirring30 rpm to 2500 rpm
12L ambient pressure reactor with bottom drain
Volume2.8 ... 12L
Temperature Range-20 ... 200°C
Material

Duran® glass (vessle, cover)
HC-22 (inserts, stirrers)
PTFE (seals, bottom drain)

StirrerPitch-blade, turbine
18L ambient pressure reactor with bottom drain
Volume3.5 ... 18L
Temperature Range-20 ... 200°C
Material

Duran® glass (vessel, cover)
HC-22 (inserts, stirrers)
PTFE (seals, bottom drain)

Stirrerpitch-blade, turbine

For further information, please contact your local METTLER TOLEDO product specialist