Conductivity Probes with 2/4 Electrodes
Conductivity Probes with 2/4 Electrodes

Conductivity Probes with 2/4 Electrodes

Versatile sensors for conductivity monitoring in chemicals, pharmaceuticals and wastewater.

Ensure Accurate Conductivity Measurement
Withstand Challenging and Rigorous Environments
Designed to Fit Your Process Needs
Plug and Measure Functionality

Products and Specs

 
Products and Specs
Filter:
Set filter
Clear All
 
Design
Segment /Application
Meas. Range / Transmitter
See details
DesignTitanium
Segment /ApplicationPure and ultrapure water
Meas. Range / Transmitter0.02-10000 µS/cm
Cell factor0.1 1/cm (nominal)
Temperature range-10...100 °C (14...212 °F)
Max. pressure (bar)34 bar (25 °C), 7 bar (95 °C)
Max. pressure (psi)500 psi (77 °F), 100 psi (203 °F)
Sensor materialPVDF
O-rings, insulationViton® (FDA), PEEK (FDA)
Temperature accuracy±0.25 °C at 25 °C
Temperature sensorPt1000
See details
DesignSS316L
Segment /ApplicationPure and ultrapure water
Meas. Range / Transmitter0.02-10000 µS/cm
Cell factor0.1 1/cm (nominal)
Temperature range-10...100 °C (14...212 °F)
Max. pressure (bar)17 bar (25°C), 7 bar (95°C)
Max. pressure (psi)250 psi (77 °F), 100 psi (203 °F)
Sensor materialSS 316L/1.4435
O-rings, insulationViton® (FDA), PEEK (FDA)
Temperature accuracy±0.25 °C at 25 °C
Temperature sensorPt1000
See details
DesignSS316L
Segment /ApplicationPharmaceutical sanitary design
Meas. Range / Transmitter0.02-2000 µS/cm
Cell factor0.1 1/cm (nominal)
Temperature range-10...120 °C (14...248 °F)
Max. pressure (bar)17 bar (25°C), 7 bar (95°C)
Max. pressure (psi)250 psi (77 °F), 100 psi (203 °F)
Sensor materialSS 316L/1.4435
O-rings, insulationPEEK (FDA)
Temperature accuracy±0.25 °C at 25 °C
Temperature sensorPt1000
See details
DesignPEEK (body)
316L (electrodes)
Hastalloy (electrodes)
Segment /ApplicationChemical, pharmaceutical and F&B processes
Meas. Range / Transmitter0.02-500 mS/cm
Temperature range-20...150 °C (-4...302 °F)
Max. pressure (bar)0 ...20 bar at 135 °C0 ...10 bar at 150 °C
Max. pressure (psi)0 ... 290 psi at 275 °F0 ... 145 psi at 302 °F
See details
DesignPEEK (body)
316L
Hastalloy
Segment /ApplicationPharmaceutical and F&B processes
Meas. Range / Transmitter0.02-650 mS/cm
Cell factor0.25 1/cm (nominal)
Temperature range-10...140 °C (14...284 °F)
Max. pressure (bar)17 bar (25 °C), 7 bar (95 °C)
Max. pressure (psi)250 psi (77 °F), 100 psi (203 °F)
Sensor materialPEEK (FDA)
O-rings, insulationPEEK (FDA)
Temperature accuracy±0.25 °C (25 °C)
Temperature sensorPt1000
See details
DesignSS316L
Segment /ApplicationCIP/SIP control and phase separation
Meas. Range / Transmitter0.02-650 mS/cm
Cell factor0.25 1/cm (nominal)
Temperature range-10...140 °C (14...284 °F)
Max. pressure (bar)17 bar (25 °C), 7 bar (95 °C)
Max. pressure (psi)250 psi (77 °F), 100 psi (203 °F)
Sensor materialPEEK (FDA)
O-rings, insulationPEEK (FDA)
Temperature accuracy±0.25 °C (25 °C)
Temperature sensorPt1000
See details
DesignSS316L
Segment /ApplicationChemical concentration measurements
Meas. Range / Transmitter0.02-650 mS/cm
Cell factor0.25 1/cm (nominal)
Temperature range-10...140 °C (14...284 °F)
Max. pressure (bar)17 bar (25 °C), 7 bar (95 °C)
Max. pressure (psi)250 psi (77 °F), 100 psi (203 °F)
Sensor materialPEEK (FDA)
O-rings, insulationPEEK (FDA)
Temperature accuracy±0.25 °C (25 °C)
Temperature sensorPt1000
See details
DesignSS316L
Segment /ApplicationIndustrial waste water
Meas. Range / Transmitter0.02-650 mS/cm
Cell factor0.25 1/cm (nominal)
Temperature range-10...80 °C (14...176 °F)
Max. pressure (bar)7 bar at 25°C
Max. pressure (psi)100 psi (77 °F)
Sensor materialCPVC
O-rings, insulationCPVC
Temperature accuracy±0.25 °C (25 °C)
Temperature sensorPt1000
See details
DesignTitanium
Segment /ApplicationWater purification
Meas. Range / Transmitter0.02-10000 µS/cm
Cell factor0.1 1/cm
Temperature range-10...100 °C (14...212 °F)
Max. pressure (bar)17 bar (25 °C), 7 bar (95 °C)
Max. pressure (psi)250 psi (77 °F), 100 psi (203 °F)
Sensor materialPTFE-coated SS 316/1.4401
O-rings, insulationViton® (FDA), PEEK (FDA)
Temperature accuracy+/- 0.25 °C
Temperature sensorPt1000
Comparison

Documentation

Case Studies

pH Monitoring in Electropolishing Case Study
This case study examines how real-time pH and conductivity monitoring in the electropolishing process reduces batch failure costs for an arterial sten...
Pure Water Analytics
This case study explains how Veolia Water Technologies was granted the building services contract for the National Graphene Institute and so turned to...
Contamination in Power Plants
This case study explains how EPS, Serbia's state-owned power company, was planning a five-year upgrade of the water chemistry analytics equipment of t...
Success Story: INGOLD Products Reduce Waste and Increase Productivity
The InPro3300 ISFET electrode has proven to be the best solution. Since its initial installation, Glanbia Foods has not had to scrap a single batch du...
Pure water fabricator
This case study explains how an Indian pure water fabricator was faced with challenges during a power plant expansion project to meet the plant's qual...

Applications

pH Measurement In Low Conductivity Samples
Power plant cycle chemistry guidelines and standards specify narrow ranges of pH to minimize corrosion of highly valuable components. In addition, mak...
UniCond® ISM Sensor Calibrator Meets Pharmacopeia Calibration Requirements
The United States Pharmacopeia (USP), European Pharmacopeia (EP) and all other Pharmacopoeias set strict guidelines for water quality and test equipme...
Power Plant Conductivity Measurement In Water Treatment and Cycle Chemistry
Conductivity measurement throughout a power plant treatment system from raw water to ultrapure water has typically required a variety of sensors to sp...
Application Note: Optimized Control of Sour Water in Petrochemical Applications
Application Note - Control of sour water without damaging the pH electrode
Key In-line Analytical Measurements in Chemical Manufacturing of APIs
The application notes provide an overview of the in-line analyses of conductivity and turbidity, which are vital parameters in improving and tracking...

Datasheets

Data Sheet: Thornton ISM Sensors for M800 and M300 ISM
Digital liquid analysis sensors optimized for pure water treatment.
Data Sheet: 2e/4e UniCond Services
Expert service of critical components maximizes availability and productivity. Execution of recommended and scheduled maintenance delivers accurate sy...

Services

Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.