Save time, reduce costs, and improve operational safety with METTLER TOLEDO's seamless automation solutions. Density measurement consists of sampling, measuring, draining, rinsing and drying. Although typically performed manually with a syringe, this workflow can be automated either for one sample or for a series of samples. Automation in density measurements minimizes the need for operator interaction with the instrument and ensures higher results reliability and fewer errors.

Automate Your Workflow

Drying Pump – DryPro
Guarantee contamination-free measurements:
Blow air through the measuring cell to dry it completely and ensure that there is no condensation left.

Sampling Pump – SPR200
Ensure consistent sampling with the SPR200 sampling pump, optimizing your sampling speed for different samples and rinsing solutions.

SV3 3-Way Valve
Want to switch from sampling to rinsing solutions, or separate your waste? The 3-way valve adds flexibility to your workflow.

InMotion Autosampler Flex – For similar samples.
The perfect solution for the beverage industry. Run multiple samples with low viscosities using a customized workflow:
- Multiple samples (15 to 303)
- Large choice of beaker sizes (25 to 250 mL)
- Rinsing with next sample
- Additional pH measurement possible in the same beaker
- Sedimentation of sample prevented by homogenizing with a stirrer
- Degassing of carbonated beverages with a combination of air flow and stirrer
- Final rinsing and testing with water

SC1 - Single Sample Automation
Tired of using a syringe? Run fully automated density measurements for any type of sample, saving time and improving the repeatability of your results. Automatic rinsing and drying ensures contamination free operations. .
- Single samples, even viscous ones (max. 36,000 mPas)
- Automatic sampling (pressurized air)
- Automatic rinsing with 2 solutions
- Automatic drying with desiccator
- Small sample volume (6, 9 or 20 mL)
- Sample recovery in cases where the sample must be retained as a reference sample

SC1H - Heated Single Sample Automation
Do you need to analyze your sample at a higher temperature? Is it too viscous or even solid at room temperature? The SC1H is the heated version of the SC1 and keeps the sample and tubing at temperatures up to 80°C.

SC30 - Multiple Samples Automation
Run a series of samples, automatically.
- Up to 30 samples, even highly viscous ones (max. 36,000 mPas)
- Automatic sampling (pressurized air)
- Automatic rinsing with 2 solutions
- Automatic drying with desiccator
- Small sample volume (6, 9 or 20 mL)
- Sample recovery in cases where the sample must be retained as a reference sample

SC30H - Heated Multiple Samples Automation
Run a series of samples at higher temperatures, automatically. The SC30H is the heated version of the SC30 and keeps the samples and tubing at temperatures up to 80°C.
Documentation
Product Brochures
Datasheets
Services
Explore our Services - Tailored to Fit your Equipment
We support and service your measurement equipment through its entire life-cycle, from installation to preventive maintenance and calibration to equipment repair.
Training & Consulting