Weighing Terminal IND131 - منتج متوقف

Weigh-Comply-Control-Connect.IND131 Process Weigh.Term.

Choice of Enclosures

Use a DIN-rail mount unit with a single analog load cell or use the junction box version to average four analog load cells

Backup and restore utility

The SD memory card utility allows easy backup and restore of setup information along with the convenience of portability.

Calibration from PLC

Choose from traditional, Step, CalFREE™ calibration methods or the new calibration from PLC feature to eliminate operator error.

رقم المادة: 64087994

Discontinued since: Feb, 2022

طلب أسعار

الملحقات - Weighing Terminal IND131

Standard Features and Benefits - Weighing Terminal IND131

  • Support for analog scale bases
  • DC (External) power supply
  • Broad connectivity options
    • Serial  - RS-232 (standard) and RS-232/485 with support for Modbus RTU protocol (optional)
    • PLC – Analog Output / A-B RIO™ / Ethernet/IP™ / Modbus® TCP / PROFIBUS® DP / DeviceNet™, ControlNet™
    • Discrete Inputs/Outputs
      • 2 Inputs /4 Outputs
      • Solid state -- open collector type
  • Optimum target control
    • Single-latched or coincidence target
    • Three coincidence comparators
    • Internal rate calculation assignable to comparators
  • Enhanced performance for process applications
    • Ultra-fast A/D conversion (366 Hz), target comparison (50 Hz) and PLC update (20 Hz) rates
    • Patented TraxDSP™ digital filtering
    • Display resolution 100,000d (max)
  • Enhanced productivity and efficiency
      • SD memory card
      • Backup and restore for setup and calibration
      • Portability of setup to other terminals
    • Calibration choices
      • Scale calibration though PLC
      • Step calibration
      • CalFREE® -Calibration without test weights
      • Traditional
  • Service friendly
    • Modular design assures ease of service and multiple mounting possibilities
    • Diagnostic LEDs and error codes for easy troubleshooting
    • TraxEMT™ performance monitoring and recording for easy operational audit
    • Serial and Discrete I/O tests
  • Weights and Measures Approvals
    • NTEP, Class III/IIIL 10,000d Coc 09-051
    • OIML, Class III 6,000e (R76/2006-NL 1-09.26)
    • MID, OIML R51/R61 
    • Canada Class III/IIIHD n max. 10000/20000
  • Hazardous Area Approvals

    • USA - FM: NI / I, II, III / 2 / ABCDEFG /, T5 Ta = 40°C, I / 2 / IIC / T5 Ta = 40°

    • Canada - FM:  NI / I / 2 / ABCD / T5 Ta, = 40°C, DIP / II, III / 2 / EFG / T5 Ta = 40°C

    • ATEX: II 3 G Ex nA nL [nL] IIC T5, II 3 D Ex tD A22 IP 65 T, 100°C

    • IECEx: Ex nA nL [nL] IIC T5, Ex tD A22 IP65 T100°C

    • NEPSI: Pending

       

المواد الاستهلاكية - Weighing Terminal IND131

برمجة - Weighing Terminal IND131