Single-Use Optical DO Sensor - InSUS 607

Single-Use Optical DO Sensor - InSUS 607

Optical Dissolved O₂ Single Use Sensor

The InSUS 607 single-use DO sensor is designed for integration into single-use bags. This single-use DO sensor uses optical technology to provide fast, accurate dissolved oxygen measurement.

Reliable Measurements
This single-use DO sensor uses optical spot (fluorescence quenching) technology to give a consistent, reliable measurement.

Stable Performance
This single-use DO sensor provides stable performance for long cell culturing runs, ensuring that your sensor will last through the full batch.

Reduced Start-Up Time
The short pre-conditioning phase of optical dissolved oxygen sensors like the InSUS 607 single-use DO sensor ensures quick start-up time.

Single-Use Optical DO Sensor - InSUS 607
Call for Quote
Specifications - Single-Use Optical DO Sensor - InSUS 607
Shelf life 36 months dry storage
Short description Optical dissolved oxygen sensor
Sensing Elements Optical spot (Fluorescensce quenching)
Integrated Temperature Probe Pt1000
Measurement range 0…250% air
Calibration 1-point air
Shaft materials High density polyethylene, USP 88 class VI
O-ring material EPDM, USP 88 class VI
Process connection Eldon James 1' port disc
Gamma ray sterilizable 25…45 kGy
Operating temperature 5…60°C (41…140°F)
Storage temperature 5…25°C (41…77°F)
Mechanical pressure resistance "2 barg / 40 °C (29 psig / 104 °F), 1 barg / 60 °C (15 psig / 140 °F)"
Approvals USP 88 class VI for all wetted polymer parts
Measurement Parameter Oxygen
Measurement Technology Optical fluorescence quenching

Features and Benefits


Ensure Process Safety
All wetted polymer materials used on the InSUS 607 single-use DO sensor are made of USP 88 class VI certified materials to ensure the highest process safety.


Easy-to-Integrate
The InSUS 607 single-use DO sensor uses a standard 1" Eldon James port disc. This unified design allows for safe and easy installation on a broad range of applications, including cell culturing, harvesting, and fermentation.


Reliable Output Signals
The output signal on the single-use DO sensor set-up is identical to the output for METTLER TOLEDO resuable DO sensors. This allows for seamless integration into existing transmitters and biocontroller process environments.


Documentation

Datasheets

Oxygen Sensor: InSUS 607
The measurement principle of the InSUS™ 607 singleuse dissolved oxygen (DO) sensor is based on proven optical spot technology and offers identical rel...

Technical Specifications

Technical Data: InSUS Sensor Series
The InSUS™ sensor series for single-use technology bioprocesses cover the measurement parameters pH and dissolved oxygen (DO).

Application Note

Bioreactor Single-Use Sensors
This application note explains the differences in operation of pH and DO single-use and reusable sensors when employed in single-use bioreactors. It f...

Accessories

Get Your Quote
Single-Use Optical DO Sensor - InSUS 607