Specifikációk - InPro 4800(i) / InPro 4881i
pH-tartomány 0 - 14 pH InPro 4800(i)1 - 14 pH InPro 4801(i), InPro 4802(i), InPro4881i
Hőmérséklet – 5 至 130 °C(23 至 266 °F)
Nyomás 130 °C 时为 12 barg(266 °F 时为 174 psig)
Cable Connection ISM: K8S; 模拟: VP
Folyamatkapcsolódások Pg 13.5 螺纹
Referencia rendszer Ag / AgCl 系统,压力补偿双凝胶电解液腔
Csatlakozás típusa 外部:PTFE 环装隔膜 内部: 非流动陶瓷隔膜
Referencia elektrolit Gel 凝胶
Hosszúságok 120 mm、225 mm、425 mm
Tengelyátmérő 12mm
Tengelyanyagok InPro 480x(i); 玻璃InPro 488xi:钛材
Hőmérséklet-érzékelő ISM: 数字模拟: Pt100 或 Pt1000
Sterilizálható
Autoklávozható
pH-membrán 随应用而异
Oldatföldelés InPro 480x(i): 铂金InPro 488xi: 钛
ATEX Certification SEV 14 ATEX 0168 XEx ia IIC T6/T5/T4/T3 Ga/Gb
FM approval IS/ I, II, III /1 /ABCDEFG /T6
IECEx Certificate of Conformity IECEx SEV 14.0025XEx ia IIC T6/T5/T4/T3 Ga/Gb
功能和用途
削减维护和更换成本
  • 这是因为采用独特的技术设计,在电解液双腔和防污 PTFE 结点处有一个很长的扩散路径。
 
ISM(“智能传感器管理”®)
  • 梅特勒-托利多新的创新型数字式“智能传感器管理®”概念提供“即插即测”功能。 从初始安装装到维护直至更换传感器,ISM 可简化并且改进过程分析系统的运行。 ISM 技术提供先进的诊断功能和更低的维护成本,可降低传感器发生故障的风险,并提高工艺可靠性。 关于 ISM 的更多信息
 
允许在各种温度范围内存在最高的操作压力
  • 非常高的压力规格在整个温度范围内有效,参见规格部分。
 
符合爆炸危险区的安全法规认证要求
  • 电极经过防爆认证,可用于爆炸危险区内的过程。
 
腐蚀性介质的平板膜提高工艺安全性
  • 带平面玻璃膜和溶液接地的 InPro4801SG 非常适合含有颗粒与纤维的介质。 溶液接地可避免接地环,也可用作诊断工具。
 
溶液接地(SG)作为选项
  • SG 作为完整的电极体涂层或 pH 电极的测量点,将改进接地并高效地消除静电干扰的风险。 SG 还可改进我们先进的诊断功能,实现平行 pH/氧化还原测量。
 
新的坚固耐用的钛电极杆结构
  • 新的 4881i 电极采用钛电极杆和不锈钢螺纹设计,带有卓越的耐化工和机械阻力。

   

Dokumentáció

Alkalmazások

Application Note: Optimized Control of Sour Water in Petrochemical Applications
Application Note - Control of sour water without damaging the pH electrode
Application Note: Improve Your Pulp & Paper Process Further with ISM Technology
Many years of experience in the field of industrial measurement systems form the basis of METTLER TOLEDO’s competence. Now with its ground-breaking IS...
Easy ISM Sensor Management in Breweries
Application Note - iSense ISM Asset Suite the professional software tool to implement innovative and efficient maintenance concepts with pre-calibrate...
pH Measurement in Amine-Based Quench Water
To control the separation and to minimize corrosion, it is important to maintain the right pH level. Therefore neutralizing agents are injected in the...
pH Control in Sugar Refineries
The process of refining sugar from cane or beets involves the following steps: washing, grinding, juicing, liming, carbonation, filtration, sulfitatio...

Tartozékok

Ajánlatot kérek
InPro 4800(i) / InPro 4881i
FDA
USP Class VI
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.