Radne stanice za sintezu za razvoj kemije i procesa - Overview - METTLER TOLEDO
Synthesis Workstations for Chemical Process Development

Radne stanice za sintezu za razvoj kemije i procesa

Replace Traditional Round Bottom Flasks and Jacketed Lab Reactors

Chemical Process Development With Synthesis Workstations
Synthesis Experimental Data
EasyMax Advanced Synthesis Workstation
OptiMax Process Development and Scale-up Workstation
Chemical Synthesis Workstation FBRM PVM
Methods to Improve Chemical Process Development
Chemical Synthesis Beyond the Round Bottom Flask

Proizvodi i specifikacije

Reduce Chemical and Process Development Times by Replacing Traditional Round Bottom Flasks and Jacketed Lab Reactors

 
Proizvodi i specifikacije
 
Temperature Range
Operating Volume
Material
Dimensions (WxDxH)
Weight
Broj artikla: 51161711
Pogledajte detalje
Temperature Range-40 °C – 180 °C
Operating Volume0.5 mL – 100 mL
MaterialPowder-coated stainless steel with FEP coated cover plate
Dimensions (WxDxH)33 cm x 36 cm x 28 cm
Weight16 kg
Heating / CoolingSolid State Thermostat
Broj artikla: 51162701
Pogledajte detalje
Temperature range-40 °C – 180 °C
Operating Volume50 mL – 1,000 mL
MaterialPowder-coated stainless steel with FEP coated cover plate
Dimensions (WxDxH)38.8 cm x 41.4 cm x 78 cm
Weight35 kg
Heating / CoolingSolid State Thermostat
Broj artikla: 30133677
Pogledajte detalje
Temperature range-40 °C – 180 °C
Operating Volume15 mL – 400 mL
MaterialPowder-coated stainless steel with FEP coated cover plate
Dimensions (WxDxH)42 cm x 36 cm x 28 cm
Weight20 kg
Heating / CoolingSolid State Thermostat
Broj artikla: 30084210
Pogledajte detalje
Temperature Range-40 °C – 180 °C
Operating Volume15 mL – 400 mL
MaterialPowder-coated stainless steel with FEP coated cover plate
Dimensions (WxDxH)42 cm x 36 cm x 28 cm
Weight20 kg
Heating / CoolingSolid State Thermostat
Broj artikla: 30133676
Pogledajte detalje
Temperature range-40 °C – 180 °C
Operating Volume0.5 mL – 100 mL
MaterialPowder-coated stainless steel with FEP coated cover plate
Dimensions (WxDxH)33 cm x 36 cm x 28 cm
Weight16 kg
Heating / CoolingSolid State Thermostat
Usporedba

Dokumentacija

Letak proizvoda

EasyMax Basic Synthesis Reactor
Synthesize more new compounds, eliminate non-viable candidates earlier and perform reaction optimization at volumes from 0.5 mL to 400 mL.
EasyMax Advanced Synthesis Reactor (A4 Size)
Smaller volume designed for reaction screening and optimization while larger volume is for scale-up experiments and crystallization studies.
OptiMax
Quickly deliver new chemical compounds, characterize the process, reduce failures, and ensure workflow and sustainability.

Povezani proizvodi i rješenja

In Situ FTRI Spektroskopija: Praćenje kemijske reakcije u realnom vremenu
Fourier Transform infracrvena spektroskopija (FTIR) za praćenje kemijskih reakcija u relanom vremenu
Linijska distribucija veličine čestica i analiza oblika čestica
Razumijevanje, optimizacija, kontrola čestica, kapljica u relanom vremenu sa In-situ sistemom za karakterizaciju čestica
Reakcijski kalorimetri za sigurnost procesa; razvoj i scale-up
Reakcijska kalorimetrija od projekcije do proizvodnje
EasySampler
EasySampler was designed to eliminate these challenges by providing an automated and robust inline method of taking representative samples from reacti...

Softver

Letak proizvoda

EasyMax Basic Synthesis Reactor
Synthesize more new compounds, eliminate non-viable candidates earlier and perform reaction optimization at volumes from 0.5 mL to 400 mL.
EasyMax Advanced Synthesis Reactor (A4 Size)
Smaller volume designed for reaction screening and optimization while larger volume is for scale-up experiments and crystallization studies.

Usluge

+385 1 29 58 131
Nazovi servis
Performanse
Održavanje i optimizacija
Usklađenost
Umjeravanje i kvaliteta
Stručnost
Obuka i savjetovanje
Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.